Page 5 - UNPACKING AND SETTING UP YOUR SCALE
©Adam Equipment Company 2009 5 2.0 INTRODUCTION Thank you for purchasing your new grain scale which is based upon the Core series of Balances. The CQT1751GR model has been specifically developed and designed to be used to assist in the grading of grain to asses the quality of the grain as well as to...
Page 6 - INSTALLING BATTERIES
©Adam Equipment Company 2009 6 3.2 INSTALLING BATTERIES Remove the battery compartment cover and insert six batteries (R6P/LR6 /AA size) into the battery compartment. 3.3 OVERVIEW - DISPLAY / KEY BOARD BEHIND AC adapter socket Lock down slot TOP Stainless Steel pan Plastic Pan LCD display [On/Off] k...
Page 8 - LOCATING AND PROTECTING YOUR SCALE
©Adam Equipment Company 2009 8 3.4 LOCATING AND PROTECTING YOUR SCALE In order to keep your scale functioning at its best we suggest that you do the following: Avoid extremes of temperature. Do not place in direct sunlight or near air conditioning vents. Make sure the scale is located on a strong ta...
Page 9 - STORING WHEN NOT IN USE; series or Core; or Grain Scale product lines you can
©Adam Equipment Company 2009 9 3.5 STORING WHEN NOT IN USE If you have any of the Highland TM series or Core TM or Grain Scale product lines you can store them easily on top of each other. To save space and protect them from damage. Without Shield With Shield
Page 10 - BASIC OPERATION; TURNING ON THE SCALE; Vol; WEIGHING
©Adam Equipment Company 2009 10 4.0 BASIC OPERATION 4.1 TURNING ON THE SCALE Plug in the unit using the AC adapter or power from the batteries and press the [on/off] key. 1) The scale will show automatically grn- X.X , “XX” meaning software revision number “grn” meaning it has grain scale software a...
Page 11 - GRAIN DETERMINING
©Adam Equipment Company 2009 11 4.5 GRAIN DETERMINING 1) Turn on the scale and wait for the scale to come to zero. Then put on an empty 500ml container and press the [Recall / Tare] key. Store Kg/Hl 2) Load the 500ml container with the grain. The screen shows the net weight (the first net weight) of...
Page 12 - For this example say 30.0g; PER; Net
©Adam Equipment Company 2009 12 4) Now remove the container and perform the screening operation. 5) Then put the same 500ml container back on to the scale. The scale will show 0.0g on the display. 6) Add the screenings to the container, the display shows the weight of the screenings. For this exampl...
Page 14 - PARAMETERS; AUTO POWER OFF
©Adam Equipment Company 2009 14 5.0 PARAMETERS The scale has 2 parameters that can be set by the user. FUNCTION SECTION DESCRIPTION Auto Off See section 5.2 Sets the auto power off function Backlight See section 5.3 Sets the backlight OFF BL backlight is off 1 BL backlight is automatic 2 BL backligh...
Page 15 - SETTING THE BACKLIGHT
©Adam Equipment Company 2009 15 5.3 SETTING THE BACKLIGHT The backlight may be enabled or disabled by the user. If the backlight is disabled, the battery life will be longer. The following settings are available: 1 BL Sets the backlight to operate automatically when a weight is placed on the scale o...
Page 16 - CALIBRATION
©Adam Equipment Company 2009 16 6.0 CALIBRATION Calibration may be required when the scale is initially installed or moved to a new location. Over time and use, mechanical deviations may occur so it is recommended that you calibrate you scale regularly. Before calibrating your should make sure you h...
Page 17 - TROUBLE SHOOTING; ERROR MESSAGES; DESCRIPTION; ADO
©Adam Equipment Company 2009 17 7.0 TROUBLE SHOOTING 7.1 ERROR MESSAGES If an error message is shown, repeat the step that caused the message. If the error message is still shown then contact your Adam Equipment dealer for support. ERROR CODE DESCRIPTION POSSIBLE CAUSES Solutions ADO A/D Value too h...
Page 18 - REPLACEMENT PARTS AND ACCESSORIES
©Adam Equipment Company 2009 18 7.2 REPLACEMENT PARTS AND ACCESSORIES If you need to order any spare parts and accessories, contact your supplier or Adam Equipment. A partial list of the more common items follows: Part Number Description 4178 AC adapter USA plug 12VAC 150mA 9541 AC adapter UK plug 1...
Page 20 - SPECIFICATIONS
©Adam Equipment Company 2009 20 8.0 SPECIFICATIONS Model # CQT1751GR Maximum Capacity 1750g Readability 0.1g Repeatability (Std Dev) 0.2g Linearity ± 0.2g Units of Measure Grams and Kilograms per hectolitre Stabilisation Time 2-3 seconds Operating Temperature 0ºC to 40ºC 32ºF to 104ºF Power Supply 1...
Page 21 - WARRANTY STATEMENT
©Adam Equipment Company 2009 21 9.0 WARRANTY STATEMENT Adam Equipment offers Limited Warranty (Parts and Labour) for the components failed due to defects in materials or workmanship. Warranty starts from the date of delivery. During the warranty period, should any repairs be necessary, the customer ...
Page 23 - Manufacturer’s Declaration of Conformity
© Adam Equipment Company 2009 Manufacturer’s Declaration of Conformity This product has been manufactured in accordance with the harmonized European standards, following the provisions of the below stated directives: Electro Magnetic Compatibility Directive 2004/108/EC Low Voltage Directive 2006/95/...
Page 24 - ADAM EQUIPMENT
© Adam Equipment Company 2009 ADAM EQUIPMENT is an ISO 9001:2000 certified global company with more than 35 years experience in the production and sale of electronic weighing equipment. For a complete listing of all Adam balances and balances visit our website at: www.adamequipment.com © Copyright b...