© Adam Equipment Company 2007 CONTENTS 1.0 INTRODUCTION....................................................................................................... 3 1.1 FEATURES: .......................................................................................................... 3 1.2 SPECIFICATIO...
Page 3 - ZERO
© Adam Equipment Company 2007 2 6.2.6 F6 -INITIAL ZERO RANGE ............................................................................... 20 6.2.7 F7 -RE-ZERO RANGE ...................................................................................... 20 6.2.8 F8 -SUCCESSIVE TARE ...................
Page 4 - Weight; plus
© Adam Equipment Company 2007 3 1.0 INTRODUCTION The AZ plus series of digital price-computing scales provide an accurate, fast and versatile method of computing price by weight. These series of scales are EC approved for the use in UK and Europe. For all revisions from 1.27 and above, the Price per...
Page 6 - INSTALLATION; equipment or large motors.; PREPARATION FOR USE; Place the platform in the receptacles on the top cover.
© Adam Equipment Company 2007 5 3.0 INSTALLATION 3.1 GENERAL INSTALLATION The scales should not be placed in a location that will reduce the accuracy. Avoid extremes of temperature. Do not place in direct sunlight or near air conditioning vents. Avoid unsuitable tables. The table or floor must be ri...
Page 7 - WINDOWS
the socket from the bottom to avoid damaging of the cable. Level the scale by adjusting the four feet. The scale should be adjusted such that the bubble in the spirit level is in the centre of the level and the scale is supported by all four feet. Turn the power ON using the switch located on the ri...
Page 8 - Unit Price; for South Africa and Far East, unit weight per 100g or per kg is not; CHARGING
The window for the Unit Price has arrows to show when the Auto Clear function is active and whether it displays the price per 100g or per kilogram. NOTE: For AZ plus for South Africa and Far East, unit weight per 100g or per kg is not available. The window for the Total Price displays the price of t...
Page 9 - DESCRIPTIONS; and Zero, the text keys are replaced by the symbol keys.
3.5 KEY DESCRIPTIONS Not applicable for South Africa and Far East Note: The AZplus scales sold in Europe have a slightly different keypad. For Tare and Zero, the text keys are replaced by the symbol keys. [., 0-9] keys Numeric entry keys to set the unit price. Pressing [.] will display the price wit...
Page 10 - ZEROING THE DISPLAY
© Adam Equipment Company 2007 9 4.0 OPERATION 4.1 ZEROING THE DISPLAY You can press the [Zero] key when no tare is entered to set the zero point from which all other weighing is measured. This will usually be necessary when the platform is empty. When the zero point is obtained the Weight display wi...
Page 12 - USING A STORED PLU VALUE FOR UNIT PRICE; OR; LOAd
© Adam Equipment Company 2007 11 4.4 USING A STORED PLU VALUE FOR UNIT PRICE The user can store and recall up to 43 PLU values (Product Look Up). The values stored are used to calculate the price for goods. The value is stored as either cost per kilogram or cost per 100g. The keys labelled [PLU1] to...
Page 13 - ENTERING VALUES FOR THE PLU s; Entering values for PLU1 to PLU3 keys
© Adam Equipment Company 2007 12 4.5 ENTERING VALUES FOR THE PLU s To store values into the memory for the PLU s follow the procedure. Entering values for PLU1 to PLU3 keys Enter the unit price value using the keypad, selecting either price/kg or price/100g if needed. Press and hold down the key [PL...
Page 14 - for South Africa and Far East.; SLEEP; SLEEP nodE
4.7 Kg/100g KEY, PRICE PER KILOGRAM, PRICE PER 100g The [kg 100g] key will change the scale from using a price per kilogram to price per 100g. It will also change the arrows under the Unit Price display to show the selection. This information is also saved for the PLU values that are stored in the m...
Page 15 - BACKLIGHT OPERATION; To enable the backlight; AU; To disable the backlight
© Adam Equipment Company 2007 14 4.9 BACKLIGHT OPERATION The backlight may be enabled or disabled by the user. If the backlight is disabled battery life will be maximised. With the backlight in operation the battery life will be less, depending upon the extent at which the scale has been used. To en...
Page 16 - PROCEDURE; Contact Adam Equipment or your supplier for more details.; CALIBRATION OF THE SCALES MAY MAKE IT ILLEGAL TO; SEALS
5.0 CALIBRATION 5.1 CALIBRATION PROCEDURE The scales are sealed to prevent unauthorised calibration. Contact Adam Equipment or your supplier for more details. The calibration of the AZ plus scale is accomplished by removing the label at the base of the scale which covers a hole through which the PCB...
Page 17 - CALIBRATION PROCEDURE; PARAMETERS; USING “0000” TO ENTER THE CALIBRATION PARAMETER
© Adam Equipment Company 2007 16 5.3 CALIBRATION PROCEDURE The scales are sealed to prevent unauthorised calibration. To calibrate the scales, access to the PCB inside is needed to place a jumper in K6 position. This is done by removing the tamper-proof label placed on a hole at the bottom of the sc...
Page 18 - USING “2003” TO ENTER THE SERVICE PARAMETERS; CAL
6.2 USING “2003” TO ENTER THE SERVICE PARAMETERS After the jumper has been placed in position K6, apply power to the scale. During the self-test press the [Tare] key. The display will ask for a code number, “ Pn - - - - “ on the Weight Display. Enter the number 2003 when “ Pn - - - - “ is displayed ...
Page 20 - WEIGHT DECIMAL POINT POSITION; -UNIT PRICE/TOTAL PRICE DECIMAL POINT LOCATION
NOTE: The scale must be originally built for the capacity selected. The 6 kg unit uses 10kg load cells, the 15 kilogram unit uses 20 kilogram load cells and the 30 kilogram unit uses 35 kilogram load cells. 6.2.4 F4 WEIGHT DECIMAL POINT POSITION To enter this parameter, press the [Tare] key when “ F...
Page 21 - -INITIAL ZERO RANGE; NOTE: Either option is allowed for the AZ
© Adam Equipment Company 2007 20 6.2.6 F6 -INITIAL ZERO RANGE To enter this parameter, press the [Tare] key when “ F6 ” is shown. The display will show the current initial zero range. Press the [PLU4] key to change the value and press [Tare] to accept the value. NOTE: Only 10% is allowed for the AZ ...
Page 22 - placed at position K6 and re-seal the scale.; –ROUNDING OFF THE TOTAL PRICE
© Adam Equipment Company 2007 21 6.2.9 F9 -A/D COUNT To enter this parameter, press the [Tare] key when “ F9 ” is shown. This parameter allows you to view the A/D counts from the internal A/D converter. This can be an aid to service. Press the [Tare] key to return to the PARAMETER menu. Press the [Z...
Page 23 - DIAGRAM
7.0 WIRING DIAGRAM © Adam Equipment Company 2007 22
Page 24 - ASSEMBLY
8.0 MECHANICAL ASSEMBLY © Adam Equipment Company 2007 23
Page 25 - LIST OF MECHANICAL ASSEMBLY
© Adam Equipment Company 2007 24 9.0 LIST OF MECHANICAL ASSEMBLY 26 front display overlay 1 25 front keyboard 1 24 screw 1 23 washer 4 22 tapping screw 4 21 washer 4 20 main PCBA 1 19 screw 5 18 screw 1 17 washer 4 16 battery cover 1 15 power switch 1 14 support feet 4 13 bottom cover 1 12 rechargea...
Page 26 - FRONT DISPLAY SCHEMATIC
10.0 FRONT DISPLAY SCHEMATIC © Adam Equipment Company 2007 25
Page 27 - MAIN PCB ASSEMBLY
11.0 MAIN PCB ASSEMBLY © Adam Equipment Company 2007 26
Page 28 - MAIN SCHEMATIC LAYOUT
12.0 MAIN SCHEMATIC LAYOUT © Adam Equipment Company 2007 27
Page 29 - PILLAR DISPLAY SCHEMATIC
13.0 PILLAR DISPLAY SCHEMATIC © Adam Equipment Company 2007 28
Page 30 - REAR DISPLAY SCHEMATIC
14.0 REAR DISPLAY SCHEMATIC © Adam Equipment Company 2007 29
Page 31 - Adam Equipment
Adam Equipment ADAM EQUIPMENT, BOND AVENUE, DENBIGH EAST INDUSTRIAL ESTATE, MILTON KEYNES, MK1 1SW, U.K. Tel: (01908) 274545 Fax: (01908) 641339 Intl Tel: -44 1908 -274545 Intl Fax: -44 1908 641339 E-Mail Address: [email protected] Test Certicifate Test certificaat Prüfzertifikat Certificato ...