Page 3 - iii; Table of Contents; Unpacking; Parts List; Installing the Recessed Camera Mount; Installing the VDA-NWDSKT Bracket
Flush Mount Ceiling Kit Table of Contents | en iii Bosch Security Systems, Inc. Mounting Guide F.01U.126.944 | 1.0 | 2009.04 Table of Contents 1 Unpacking 1 1.1 Parts List 1 1.2 Safety Rules 3 2 Installing the Recessed Camera Mount 4 2.1 Installing the VDA-NWDSKT Bracket 5 2.2 Mounting the FlexiDome...
Page 4 - iv; en | Table of Contents
iv en | Table of Contents Flush Mount Ceiling Kit F.01U.126.944 | 1.0 | 2009.04 Mounting Guide Bosch Security Systems, Inc.
Page 5 - Flush Mount Ceiling Kit; Quantity
Flush Mount Ceiling Kit Unpacking | en 1 Bosch Security Systems, Inc. Mounting Guide F.01U.126.944 | 1.0 | 2009.04 1 Unpacking Unpack this equipment and handle with care. If an item appears to have been damaged in shipment, notify the shipper immediately. Verify that all the parts listed in the sect...
Page 6 - The illustration below shows a typical installation:; Typical VDA-NWDFMT installation; Recess bracket with backplate
2 en | Unpacking Flush Mount Ceiling Kit F.01U.126.944 | 1.0 | 2009.04 Mounting Guide Bosch Security Systems, Inc. The illustration below shows a typical installation: Figure 1.1 Typical VDA-NWDFMT installation 1 Drywall ceiling or ceiling tile, 6–23 mm (.24–.91 in.) thick 2 Recess bracket with back...
Page 7 - Safety Rules; Operating Instructions
Flush Mount Ceiling Kit Unpacking | en 3 Bosch Security Systems, Inc. Mounting Guide F.01U.126.944 | 1.0 | 2009.04 1.2 Safety Rules To ensure safety, the following warnings are specified: – The device must be installed and maintained by skilled technical personnel. – Connect the device to a power so...
Page 8 - Note; Combined weights for bracket and cameras; Item
4 en | Installing the Recessed Camera Mount Flush Mount Ceiling Kit F.01U.126.944 | 1.0 | 2009.04 Mounting Guide Bosch Security Systems, Inc. 2 Installing the Recessed Camera Mount Use this mount to install a FlexiDome IP (NWD-4xx) camera or an AutoDome Easy Analog or IP (VEZ series) camera. The VDA...
Page 9 - VDA-NWDSKT Support Kit
Flush Mount Ceiling Kit Installing the Recessed Camera Mount | en 5 Bosch Security Systems, Inc. Mounting Guide F.01U.126.944 | 1.0 | 2009.04 2.1 Installing the VDA-NWDSKT Bracket The VDA-NWDSKT is a support bracket for the VDA-NWDFMT Flush Mount Ceiling kit. Use this bracket to add support to a cei...
Page 10 - Mounting the FlexiDome IP Camera; FlexiDome IP components
6 en | Installing the Recessed Camera Mount Flush Mount Ceiling Kit F.01U.126.944 | 1.0 | 2009.04 Mounting Guide Bosch Security Systems, Inc. 2.2 Mounting the FlexiDome IP Camera Use the following image as a reference for the following procedure: Figure 2.2 FlexiDome IP components 1. Determine a sec...
Page 11 - At tach mounting plate to backplate
Flush Mount Ceiling Kit Installing the Recessed Camera Mount | en 7 Bosch Security Systems, Inc. Mounting Guide F.01U.126.944 | 1.0 | 2009.04 5. Loosen the three tamper-resistant screws in the FlexiDome IP Trim Ring (the screws remain in place) using a T20 pin- in Torx driver. Remove the Trim Ring w...
Page 12 - Slide the Mounting Plate/Bracket assembly into the cutout; Insert recess bracket into ceiling; bolts grasp the ceiling tile. Do not overtighten the support; Tighten toggle bolts
8 en | Installing the Recessed Camera Mount Flush Mount Ceiling Kit F.01U.126.944 | 1.0 | 2009.04 Mounting Guide Bosch Security Systems, Inc. 13. Slide the Mounting Plate/Bracket assembly into the cutout in the ceiling tile. You may have to push the support screws from below to engage the toggle bol...
Page 13 - At tach suspension wire; FlexiDome IP Operating
Flush Mount Ceiling Kit Installing the Recessed Camera Mount | en 9 Bosch Security Systems, Inc. Mounting Guide F.01U.126.944 | 1.0 | 2009.04 15. Attach a suspension wire to the top of the recess bracket at one of the points indicated below and then to a structural element in the ceiling. Figure 2.6...
Page 14 - At tach safety tether; Operation Manual
10 en | Installing the Recessed Camera Mount Flush Mount Ceiling Kit F.01U.126.944 | 1.0 | 2009.04 Mounting Guide Bosch Security Systems, Inc. 18. Attach one end of the safety tether to the hook on the Mounting Plate and the other end to the hook on the Camera Module/Base. Figure 2.7 At tach safety ...
Page 15 - At tach recess trim ring
Flush Mount Ceiling Kit Installing the Recessed Camera Mount | en 11 Bosch Security Systems, Inc. Mounting Guide F.01U.126.944 | 1.0 | 2009.04 23. Attach the Recess Trim Ring with the three #8-32 x 5/8 in. self-tapping screws. Figure 2.8 At tach recess trim ring
Page 16 - Remove brass rings from AutoDome Easy
12 en | Installing the Recessed Camera Mount Flush Mount Ceiling Kit F.01U.126.944 | 1.0 | 2009.04 Mounting Guide Bosch Security Systems, Inc. 2.3 Mounting the AutoDome Analog/IP Camera 1. Determine a secure location for the flush mount ceiling kit. Refer to Table 2.1, Page 4 , for weight informatio...
Page 17 - At tach AutoDome Easy to backplate; AutoDome Operating Instructions
Flush Mount Ceiling Kit Installing the Recessed Camera Mount | en 13 Bosch Security Systems, Inc. Mounting Guide F.01U.126.944 | 1.0 | 2009.04 6. Route the wires from the AutoDome Easy through the slot in the Recess bracket. 7. Align the three holes on the top of the AutoDome Easy with the three sma...
Page 18 - Slide the AutoDome Easy Bracket assembly into the cutout; Insert recess bracket/camera assembly into ceiling; bolts grasp the ceiling. Do not overtighten the support
14 en | Installing the Recessed Camera Mount Flush Mount Ceiling Kit F.01U.126.944 | 1.0 | 2009.04 Mounting Guide Bosch Security Systems, Inc. 12. Slide the AutoDome Easy Bracket assembly into the cutout in the ceiling tile. You may have to push the support screws from below to engage the toggle bol...
Page 19 - Attach suspension wire
Flush Mount Ceiling Kit Installing the Recessed Camera Mount | en 15 Bosch Security Systems, Inc. Mounting Guide F.01U.126.944 | 1.0 | 2009.04 14. Attach a suspension wire to the top of the recess bracket at one of the points indicated below and then to a structural element in the ceiling. Figure 2....