Page 2 - Owner's Manual Supplement; System Requirements; UL Listed Local Bell
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 2 Bosch Security Systems, Inc. | 9/11 | F01U245224-02 System Requirements Minimum system requirements for Classification in accordance with ANSI/SIA CP-01-2007: • UL Listed and Classified control unit Model D9412GV4, D7412GV4, or D7212GV4 • UL L...
Page 3 - Introduction 4
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U245224-02 3 1.0 Introduction 4 2.0 General Commands 4 2.1 Two-Man Rule 4 2.2 Early Ambush 5 2.3 Easy Exit Control 5 2.4 Passcode Follows Scope 6 2.5 Passcode Controlled Menu 7 2.6 Walk Tests 8 2.7 Door A...
Page 4 - General Commands; Rule; I have this feature.
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 4 Bosch Security Systems, Inc. | 9/11 | F01U245224-02 1.0 Introduction This document supplements the Security System Owner’s Manual (P/N: 71-06633-000) with the features for the GV4 Series. The instructions for the commands listed in this docume...
Page 5 - Ambush; Disarm Now; Easy Exit Control
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U245224-02 5 2.2 Early Ambush 2.2.1 Description Early Ambush adds an extra step to the disarming process by requiring the entry of an additional passcode to confirm that the area is secure. The second pas...
Page 6 - Passcode Follows Scope; YES
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 6 Bosch Security Systems, Inc. | 9/11 | F01U245224-02 2.3.2 Using Easy Exit Control Switching armed states from Master to Perimeter: 1. Ensure that the keypad shows idle master armed text. 2. Press the [COMMAND] key. The keypad shows SYSTEM COMM...
Page 7 - Passcode Controlled Menu
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U245224-02 7 2.4.2 Using Passcode Follows Scope Arming from a keypad with Panel Wide scope and Passcode Follows Scope enabled: 1. Ensure that the keypad shows idle disarmed text. 2. Ensure that you have a...
Page 8 - Tests
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 8 Bosch Security Systems, Inc. | 9/11 | F01U245224-02 2.5.2 Using Passcode Controlled Menus On a D1255 Keypad 1. Press the [ESC] key. The keypad shows ENTER PASSCODE . 2. Enter your passcode by pressing the passcode digits followed by the [ENT] ...
Page 9 - Table 1: Walk Test Menu Access
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U245224-02 9 Table 1: Walk Test Menu Access Test Type Command Sequence Menu Function Name Point Types Tested Walk [COMMAND][4][4] WALK TEST ? Visible Perimeter and Interior Fire [COMMAND][5][8] FIRE TEST ...
Page 10 - Table 2: Hardware States of Points; remain to
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 10 Bosch Security Systems, Inc. | 9/11 | F01U245224-02 Table 2: Hardware States of Points Display Text Hardware State 1PT### NORMAL HW Normal 1PT### OPEN HW Opened 1PT### SHORT HW Shorted 1PT### MISSNG HW Missing 9. Activate the point’s sensor a...
Page 11 - Door Activated Custom Function
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U245224-02 11 The point state can be NORMAL , OPEN , SHORT , or MISSING . 7. Activate the point’s sensor and observe the state change. 8. Repeat Steps 5 through 7 until all points are tested. 2.7 Door Act...
Page 12 - Authentication; When a keypad and door
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 12 Bosch Security Systems, Inc. | 9/11 | F01U245224-02 I have One of the following Passcode Functions configured: Arm / Disarm (default) - All areas within the scope of the user and keypad have their arm state changed. If the current area is arm...
Page 13 - Access Level Control; ACCESS LEVEL CTL
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U245224-02 13 The Dual Authentication process is also valid if the access credential is presented first. Access credentials are usually a token or a card and are provided by your dealer. The control panel...
Page 14 - Control; SYSTEM
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 14 Bosch Security Systems, Inc. | 9/11 | F01U245224-02 On a D1260 Keypad 1. Activate the door’s custom functions. Refer to Section 2.7.2 Using Door Activated Custom Functions. 2. Ensure that the display shows idle disarmed text. 3. Press the Men...
Page 16 - Table 3: Key to Symbols; ENT
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 16 Bosch Security Systems, Inc. | 9/11 | F01U245224-02 Table 3: Key to Symbols Symbol Description --- Door is not active, not in scope, or user does not have access level authority C Door is timed door sequence U Strike and shunt are latched act...
Page 27 - Requirements; The minimum system requirements for SIA CP-01 compliance are:; Table 4: System Requirements; False Alarm Reduction Features
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U245224-02 27 3.0 SIA CP-01 Compliance Information Warning: The default programming for the control panel includes a 30-second communication delay for alarms on non-fire zone types. It can be removed (or ...
Page 28 - User-Caused False Alarms, Arming the System; Time; DISARM NOW
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 28 Bosch Security Systems, Inc. | 9/11 | F01U245224-02 3.3 User-Caused False Alarms, Arming the System 3.3.1 Exit Time Defaults The SIA standard calls for Exit Time to range from 45 sec to at least two min (not to exceed 255 sec). The default is...
Page 29 - Arm; Closing; Recent Closing events are not created for Fire Alarm events.; ENTER
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U245224-02 29 3. The user does not return to stop Entry Delay. The Entry Delay time expires. 4. The control panel starts the alarm transmission sequence, accompanied by an Exit Error report. 3.3.5 Master ...
Page 30 - Arming and Disarming with Keyswitches; Arming Beeps and Flashes; Alarm Transmission Sequence – Alarm Abort; Window; The Abort Window is programmable.
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 30 Bosch Security Systems, Inc. | 9/11 | F01U245224-02 3.5 Arming and Disarming with Keyswitches Arming Beeps and Flashes The SIA standard requires that the control panel provide a means to annunciate a change in arming state made from a Keyswit...
Page 31 - Alarms Acknowledged within the Abort Window; If the end user acknowledges an alarm within the Abort Window:; At the End of the Alarm Abort Window; Report; This feature allows for a
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U245224-02 31 3.6.3 Alarms Acknowledged within the Abort Window If the end user acknowledges an alarm within the Abort Window: • The alarm output is silenced. • No alarm, restoral, or cancel reports are s...