Page 3 - Table of Contents; Safety
DINION capture 5000/7000 Table of Contents | en 3 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 Table of Contents 1 Safety 5 1.1 Safety precautions 5 1.2 Important safety instructions 6 1.3 Important notices 9 1.4 FCC & ICES compliance 13 1.5 Bosch notices 15 2 Description 16 ...
Page 4 - Dimensional Drawings
4 en | Table of Contents DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc. 4.5.6 Color submenu (Overview Camera - DINION capture 7000 only) 43 4.5.7 VMD submenu 44 4.6 Install menu structure 45 4.6.1 Language submenu 46 4.6.2 Lens Wizard submenu 46 4.6.3 Alarm...
Page 5 - Safety precautions
DINION capture 5000/7000 Safety | en 5 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 1 Safety 1.1 Safety precautions DANGER! High risk: This symbol indicates an imminently hazardous situation such as "Dangerous Voltage" inside the product. If not avoided, this will result ...
Page 6 - Important safety instructions; Object and liquid entry -
6 en | Safety DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc. 1.2 Important safety instructions Read, follow, and retain for future reference all of the following safety instructions. Heed all warnings on the unit and in the operating instructions before ope...
Page 7 - Damage requiring service -
DINION capture 5000/7000 Safety | en 7 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 8. Power disconnect - Units have power supplied to the unit whenever the power cord is inserted into the power source. The power cord plug is the main power disconnect device for switching off the...
Page 9 - Important notices; RISK GROUP 1
DINION capture 5000/7000 Safety | en 9 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 1.3 Important notices All-pole power switch - Incorporate an all-pole power switch, with a contact separation of at least 3 mm in each pole, into the electrical installation of the building. If it...
Page 10 - National Electrical Code,; Electronic Surveillance -; EC
10 en | Safety DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc. The Exposure Hazard Value for the product (ratio of the Exposure level to the Exposure limit) is up to 1.8 at a test distance of 200 mm or 8 inches. The Hazard Distance (distance beyond which the...
Page 11 - Environmental statement -; Article
DINION capture 5000/7000 Safety | en 11 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 Environmental statement - Bosch has a strong commitment towards the environment. This unit has been designed to respect the environment as much as possible. Electrostatic-sensitive device - Use p...
Page 13 - FCC & ICES compliance; FCC & ICES Information; Class A; FCC Rules; commercial; How to Identify; Informations FCC et ICES
DINION capture 5000/7000 Safety | en 13 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 1.4 FCC & ICES compliance FCC & ICES Information (U.S.A. and Canadian Models Only) This device complies with part 15 of the FCC Rules . Operation is subject to the following conditions: –...
Page 14 - Classe A; section 15 du règlement; installation commerciale; How to Identify and Resolve Radio-TV Interference Problem
14 en | Safety DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc. – cet appareil ne peut pas provoquer d'interférence nuisible et – cet appareil doit pouvoir tolérer toutes les interférences auxquelles il est soumit, y compris les interférences qui pourraient i...
Page 15 - Bosch notices; Video loss
DINION capture 5000/7000 Safety | en 15 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 1.5 Bosch notices Video loss Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information....
Page 16 - Description; Parts List; Quantity
16 en | Description DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc. 2 Description The DINION capture is a specialty camera designed to capture consistent, high-quality images of vehicle license plates. Available in IP and analog versions, it is ideal for mon...
Page 17 - Installing the DINION capture; Determining the Range; Ranges based on capturing:
DINION capture 5000/7000 Installing the DINION capture | en 17 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 3 Installing the DINION capture This section provides instructions for mounting and wiring the DINION capture. 3.1 Determining the Range The DINION capture has a recommende...
Page 18 - Determining the Angle
18 en | Installing the DINION capture DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc. Table 3.1 Ranges for DINION capture 5000 and 7000 Analog Imagers 3.2 Determining the Angle The maximum mounting angle of the license plate camera to the car is 40° for spee...
Page 20 - Mounting the DINION capture; MBE Mounts and Adapters Installation Guide
20 en | Installing the DINION capture DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc. 3.3 Mounting the DINION capture For a secure mounting installation, bolts should extend through the mounting surface and be secured with nuts, washers, and lock washers on ...
Page 21 - Section 3.1 Determining the
DINION capture 5000/7000 Installing the DINION capture | en 21 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4. Secure the mounting bracket to the mounting surface. Use four (4) corrosion-resistant, stainless steel studs or bolts, nuts, washers, and lock washers (not supplied). 5....
Page 23 - Preparing the Wiring; Power Input Connections
DINION capture 5000/7000 Installing the DINION capture | en 23 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 3.4 Preparing the Wiring The DINION capture 5000 comes pre-wired with a single two- wire power input lead and a single 75 ohm coaxial video cable output lead terminated wit...
Page 24 - Making the Connections
24 en | Installing the DINION capture DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc. 3.5 Making the Connections The easiest way to connect the cables is as follows: 1. Bring the building connections through the surface cable hole so that they hang clear. 2....
Page 25 - Mode Details
DINION capture 5000/7000 Installing the DINION capture | en 25 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 operates as desired during darker conditions but overexposes the image during sunny conditions. IMPORTANT: Only setup Automatic Mode Switching if the target license plate i...
Page 26 - To setup Automatic Mode Switching:
26 en | Installing the DINION capture DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc. To setup Automatic Mode Switching: 1. Ensure to setup during the brightest conditions of the day, the plate image should appear very bright before setup. 2. Remove the back...
Page 27 - To disable Automatic Mode Switching:
DINION capture 5000/7000 Installing the DINION capture | en 27 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 To disable Automatic Mode Switching: 1. Navigate to the Install menu for the license plate camera. Refer to Section 4.1 Menus, page 28 . 2. Navigate to the Alarm I/O menu. ...
Page 28 - Configuration; Menus; Top level menus
28 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc. 4 Configuration The DINION capture normally provides an optimal picture for capturing license plates without the need for further adjustments. Advanced setup options are available for gett...
Page 29 - To access the keypad for the license plate camera:
DINION capture 5000/7000 Configuration | en 29 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 To access the keypad for the license plate camera: 1. Remove the four (4) hex socket screws from the back panel using the supplied 3 mm hex key. 2. Locate the keypad inside the imager. 1 U...
Page 30 - To access the keypad for the overview camera:
30 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc. To access the keypad for the overview camera: 1. Remove the hex socket screw from the back panel using the supplied 3 mm hex key. 2. Locate the keypad inside the imager. 1 Up key 2 Right k...
Page 31 - Menu Navigation Keys; Exit
DINION capture 5000/7000 Configuration | en 31 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4.1.3 Menu Navigation Keys Five keys are used for navigating through menu system. – Use the up or down keys to scroll through a menu. – Use the left or right keys to move through options o...
Page 32 - Auto
32 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc. 4. Mode 4 Default settings. 5. Mode 5 Default settings. 6. Mode 6 Default settings. 4.3 Day/Night switching (DINION capture 7000) The overview camera is equipped with a motorized IR filter...
Page 33 - Disabled camera buttons
DINION capture 5000/7000 Configuration | en 33 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4.4 Camera control communication (Bilinx) The DINION capture is equipped with a coaxial communications transceiver (also referred to as Bilinx). In combination with VP- CFGSFT, the camera ...
Page 34 - Main menu structure; Item
34 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc. 4.5 Main menu structure Refer to Section 4.1 Menus, page 28 , to access the Main menu. Item Selection Description Mode Submenu Sets up operating modes 1 to 6 ALC Submenu Video level contro...
Page 35 - Mode submenu
DINION capture 5000/7000 Configuration | en 35 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4.5.1 Mode submenu 4.5.2 ALC submenu Item Selection Description Mode 1 to 6 Selects operating mode. Mode ID Alphanumeric Mode name (10 characters maximum) Copy active mode Available mode n...
Page 41 - Enhance / Dynamic Engine submenu
DINION capture 5000/7000 Configuration | en 41 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4.5.5 Enhance / Dynamic Engine submenu NOTICE! The Enhance settings are factory set to work optimally for capturing license plates, only an experienced user should change these settings. U...
Page 44 - VMD submenu
44 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc. 4.5.7 VMD submenu Selecting an area for VMD masking To set-up an area for VMD masking, access the area menu by selecting the VMD Area option from the VMD menu. Upon entering the Area menu,...
Page 45 - not; Install menu structure
DINION capture 5000/7000 Configuration | en 45 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 Note: When VMD is enabled, normal light fluctuations or environmental factors can contribute to false-positive alarms. Because of this, it is recommended that you do not connect the VMD-tr...
Page 46 - Language submenu
46 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc. 4.6.1 Language submenu 4.6.2 Lens Wizard submenu Item Selection Description Language English Spanish French German Portuguese Polish Italian Dutch Russian Displays the menus on the OSD in ...
Page 48 - Connections submenu
48 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc. 4.6.4 Connections submenu Alarm output VMD, External device, Night mode active, Filter toggle VMD: - output relay closes on VMD alarms. External device: - make the output relay available t...
Page 49 - Test signal submenu
DINION capture 5000/7000 Configuration | en 49 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4.6.5 Test signal submenu Compensation level 0,1,2 . . .+15 Sets the level of cable compensation Bilinx Comms. On, Off If Off, Bilinx communications is disabled. EXIT Returns to Install me...
Page 50 - Camera ID submenu
50 en | Configuration DINION capture 5000/7000 | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc. 4.6.6 Camera ID submenu Item Selection Description Camera ID Enter a 17-character camera name. Use Left/Right to change position in the string; use up/down to select character. Use Select ...
Page 51 - Privacy masking submenu
DINION capture 5000/7000 Configuration | en 51 Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01 4.6.7 Privacy masking submenu Selecting an area for privacy masking To set-up an area for privacy masking, access the area menu by selecting the Area option from the privacy masking menu. ...