MODELS

ILB9

!!!!!

ILB11

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer.

If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service

panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service discon-
necting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a quali-

fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting

of gases through the flue (chimney) of fuel burning equipment
t o p r e v e n t b a c k d r a f t i n g . F o l l o w t h e h e a t i n g e q u i p m e n t
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage elec-

trical wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be

marked as appropriate for the application and be connected to
a GFCI (Ground Fault Interrupter) - protected branch circuit.

9. Never place a switch where it can be reached from a tub or

shower.

10. This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

1. Never leave surface units unattended at high settings. Boilovers

cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.

2. Always turn hood ON when cooking at high heat or when

flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Pepper-
corn Beef Flambe’).

3. Clean ventilating fans frequently. Grease should not be allowed

to accumulate on fan or filter.

4. Use proper pan size. Always use cookware appropriate for the

size of the surface element.

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOW-
ING:*

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal

tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.

2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - vio-

lent steam explosion will result.

IN-LINE BLOWERS

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 4.

!

FOR DOMESTIC COOKING ONLY

!

WARNING

4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already

know how to operate it.

B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.

CAUTION

!

1. For general ventilating use only. Do not use to exhaust hazard-

ous or explosive materials and vapors.

2. To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc. off power
unit.

3.

If ventilator is installed in an unconditioned space (such as
an attic):

Surround the ventilator with thermal insulation - to

minimize possible condensation.

4. Please read specification label on product for further informa-

tion and requirements.

TABLE OF CONTENTS

This manual is divided into sections as follows:

!

“TYPICAL INSTALLATION”

This section shows a common installation.
- Mounting (New Frame Construction)
- Mounting (Existing Frame Construction)
- Mounting Using Hanger Kit (included)
- Ducting (Horizontal blower discharge)
- Wiring

!

“MOUNTING OPTIONS”

!

“WIRING PLATE POSITION”

!

“DUCTING OPTIONS”

- Blower Discharge Positions
- Ducting (Vertical blower discharge)

!

“USE AND CARE”

!

“SERVICE PARTS”

!

“WARRANTY”

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - MODELS; Blower factory-shipped in straight-through; DUCTING; Two ways to connect ductwork to a factory-shipped unit.; TYPICAL INSTALLATION; MOUNTING; MOUNTING; Factory-shipped unit installed in existing construction.; Remove shipping tape from damper

Page 2 MODELS ILB9 !!!!! ILB11 MOUNTING USING HANGER KIT (included) Blower factory-shipped in straight-through discharge position. TYPICAL INSTALLATION DUCTING (Horizontal blower discharge) Two ways to connect ductwork to a factory-shipped unit. ROOF CAP 10” ROUND ELBOW 10” ROUND DUCT WALL CAP 8” X ...

Page 3 - WIRING PLATE POSITION; BLOWER DISCHARGE POSITIONS; MOUNTING OPTIONS; WIRING

Page 3 MODELS ILB9 !!!!! ILB11 WIRING PLATE POSITION DUCTING OPTIONS BLOWER DISCHARGE POSITIONS Wiring plate mounts to side or top of housing. HORIZONTAL POWER CABLE CONNECTION VERTICAL POWER CABLE CONNECTION Ventilator shown in straight-through discharge position. (Factory shipped) DUCT CONNECTOR (...

Page 4 - SERVICE PARTS; WARRANTY; USE AND CARE

Page 4 MODELS ILB9 !!!!! ILB11 SERVICE PARTS KEY NO. PART NO. DESCRIPTION 1 97014853 Damper Flap 2 99150415 Screw, #8B x ¼* (16 req.) 3 98009520 Duct Connector (2 req.) 4 97014784 Housing Assembly 5 97014728 Mounting Bracket (2 req.) 6 99150591 Mounting Screw (4 req.) 7 97006142 Wiring Harness 8 991...