BEA DR - Manual
BEA DR – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – During a detection the red LED lights on.
- Page 4 – DESCRIPTION OF THE INFRARED REMOTE CONTROL; Open the battery compartment at the back of the remote control ; CONFIGURATION OF THE SENSOR; UNLOCK with access code; LOCK; LOCK with access code change
- Page 5 – The red LED is then slowly flashing.
75.5268.01 20070111
Page 1 of 7
FALCON DR / FALCON XL-DR
USER’S GUIDE
MOTION SENSORS FOR INDUSTRIAL DOORS
FALCON DR:
double relay / high mount
•
FALCON XL-DR:
double relay / low mount
Technology
: Microwave and
microprocessor
Transmitter frequency
: 24.125 GHz
Transmitter radiated power : <20 dBm EIRP
Transmitter power density
: < 5 mW/cm²
Mounting height
•
FALCON DR
: from 11.5’ (3.5m) to 23’ (7m)
•
FALCON XL-DR
: from 6.5’ (2m) to 11.5’ (3.5m)
Tilt angles
: 0° to 180° in elevation
Detection zone
•
FALCON DR
(mounting height of 5m)
:
13’ (W) x 16’ (D)
4m (W) x 5m (D)
•
FALCON XL-DR
(mounting height of 2.5m)
:
13’ (W) x 6.5’ (D)
4m (W) x 2m (D)
Detection mode
: Motion
Minimum speed
: 2 in (5cm)/s (measured in the
sensor axis)
Supply voltage
: 12V to 24V AC ±10%
12V to 24V DC +30% / -10%
Mains frequency
: 50 to 60 Hz
Power consumption
: < 2W (VA)
Two Output relay (free of potential change-over contact)
•
Max. contact voltage
: 42V AC
•
Max. contact current
: 1A (resistive)
•
Max. switching power
: 30W (DC) / 60VA (AC)
Hold time
: 0.5s to 9s (adjustable)
Temperature range
: -22°F to +122°F (-30°C to +60°C)
Degree of protection
: IP65
Norm conformity
: R&TTE 1999/5/EC
EMC 89/336/EEC
Dimensions :
4” (W) x 5” (D) x 3 ¾” (H)
102 mm (W) x 127 mm (D) x 96 mm (H)
Weight :
0.88 lbs (0.4 kg)
Material of housing
: ABS and polycarbonate
Material of bracket
: Anodized aluminium
Length of cable
: 33’ (10m)
Manual adjustment
•
Orientation of sensing field (mechanically)
•
Multiple functions (by push buttons)
Remote control adjustments
•
Sensitivity
•
Hold time
•
Detection mode
•
Pedestrian and parallel traffic rejection mode
•
Output configuration
•
Security
The sensor must be firmly
fastened to prevent from
vibrating.
The sensor must not be placed
directly behind a panel or any kind
of material.
The sensor must not have
any object likely to move or
vibrate in its sensing field.
The sensor must not have any
fluorescent lighting in its
sensing field.
DESCRIPTION OF
THE SENSOR
INSTALLATION
TIPS
TECHNICAL
SPECIFICATION
Tranceiver module
(planar antenna)
Green LED
Infrared Receiver
Red LED
2 Push Buttons
Microprocessor
Terminal block
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
75.5268.01 20070111 Page 3 of 7 FALCON (Mounting height: 16.5’ (5m) FALCON (Mounting height: 11.5’ (3.5 m) FALCON XL (Mounting height: 8’ (2.5 m) • When the power is turned ON the red and green LED flash for a few seconds. • During a detection the red LED lights on. • During configuration the red LE...
75.5268.01 20070111 Page 4 of 7 1. DESCRIPTION OF THE INFRARED REMOTE CONTROL • Open the battery compartment at the back of the remote control ; • Insert two AAA batteries supplied with the remote control as shown beside ; • Close the battery compartment. 0-9 Number keys (1) Output redirection (2) P...
75.5268.01 20070111 Page 5 of 7 Note: All parameters or functions listed in the following tables are only accessible if the sensor is in adjustment session. The red LED is then slowly flashing. During an adjustment session each parameter may be checked or changed at any time in the following way: PA...