BEA Infrared Zone Locator - Manual
BEA Infrared Zone Locator – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
LED COLOR: POSITION
‘ORANGE’ LED FOR POSITION
‘RED’ LED FOR POSITION
‘GREEN’ LED FOR POSITION
SPOTFINDER
USER’S GUIDE
INFRARED ZONE LOCATOR
1 Description & Specifi cations
75.0176.04
20080331
Page
1
of
2
BEA’s Infrared (IR) Spotfi nder is a
hand-held tool used to locate an
active infrared source.
This easily locates an IR area
which can be used to assist in the
palcement of the sensing zone as
well as approximate the distance
from a sensor.
The Spotfi nder has two settings,
(1) LED only (light, no sound) or
(2) LED and Buzzer.
This accessory will shut-off after
45 seconds of no IR activity. To
reactivate, switch OFF then back
ON by selecting either LED or
BUZZER.
POSITION
LED COLOR
BUZZER LEVEL
IR LIGHT LEVEL
1
GREEN
NONE
NONE
2
ORANGE
SOFT - WEAK
LOW
3
RED
LOUD - STRONG
HIGH
N/A
FLASHING ORANGE
LOW BATTERIES
2 Settings & Placement
DESCRIPTION
SPECIFICATION
POWER SUPPLY
AAA Alkaline Batteries (2) Included
DIMENSIONS
3” X 2 1/4” X 1” (76mm x 57mm x 25mm)
MATERIAL
ABS Plastic
For sliding door overhead presence detection, place the Spotfi nder fl at on the fl oor so that the IR-SPOT is at the appropriate
distance from the door face. Adjust the IR Curtain on the sensor until the LED turns Orange and/or the Buzzer begins to beep
(as in Position 2 below).
NOTE: The Spotfi nder only serves to identify an area of infrared light and not necessarily imply the area of the sensors detection.
BEA, Inc. always recommends a walk test to ensure compliance to all applicable standards for sensing patterns.
See ANSI
A156.10 for
Required
Distance