BEA FALCON XL - Manual
BEA FALCON XL – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Opening the sensor; US Wire Color:
- Page 3 – During a detection the red LED lights on.; SETTING
- Page 7 – SYMPTOM; SHOOTING
75.5351.02 EN 20080317 (75.5350)
Page 1 of 7
FALCON & FALCON XL
USER'S GUIDE
MOTION SENSORS FOR INDUSTRIAL DOORS
•
FALCON
: for high mounting
•
FALCON XL
: for low mounting
Technology:
Microwave and microprocessor
Transmitter frequency:
24.125 GHz
Transmitter radiated power:
<20 dBm EIRP
Transmitter power density:
< 5 mW/cm²
Mounting height
FALCON: from 11.5 to 23’
FALCON XL: from 6.5 to 11.5’
Tilt angle:
0° to 180° in elevation
Detection zone (typical)
Wide pattern (FALCON XL): 13’ (W) x 6.5’ (D)
for a mounting height of 8.2’
Narrow pattern (FALCON): 13’ (W) x 16’ (D)
for a mounting height of 16’
Detection mode:
movement
Minimum detection speed
:
2.2 in/s (measured in the
sensor axis)
Supply voltage:
12V to 24V AC +/- 10%
12V to 24V DC +30% / -10%
Mains frequency:
50 to 60 Hz
Power consumption
: <
2W
Output relay:
free of potential changeover contact
Max contact voltage : 42V AC/ DC
Max contact current: 1A (resistive)
Max switching power: 30W (DC) / 60 VA (AC)
Hold time:
0.5s to 9s (adjustable)
Manual adjustment:
•
orientation of sensing field (mechanically)
•
multiple functions (by push buttons).
Remote control adjustments:
•
Sensitivity.
•
Hold time.
•
Detection mode.
•
Pedestrian and parallel traffic rejection mode.
•
Relay configuration.
Temperature range :
-22°F to 122°F (-30°C to +60°C)
Degree of protection:
IP65
Product conformity:
R&TTE 1999/5/EC
EMC
89/336/EEC
Dimensions :
5 in (D) x 4 in (W) x 3 ¾ (H)
(127mm (D) x 102 mm (W) x 96mm (H))
Weight:
0.88 lbs (400 g)
Housing Material:
ABS and Polycarbonate
Bracket Material:
black anodized aluminum
Cable length:
33 ft (10 m)
Cable diameter:
1/8” (3 mm) (minimum)
1/4” (6.5 mm) (maximum)
The sensor must be firmly
fastened in order not to
vibrate.
The sensor must not be
placed directly behind a
panel or any kind of
material.
The sensor must not
have any object likely to
move or vibrate in its
sensing field.
The sensor must not
have any fluorescent
lighting in its sensing
field.
DESCRIPTION OF
THE SENSOR
INSTALLATION
TIPS
TECHNICAL
SPECIFICATIONS
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
75.5351.02 EN 20080317 (75.5350) Page 2 of 7 To remove or to insert the cable: • Unscrew the retaining nut; • Pass the cable through the grommet and the retaining nut. • Tighten the retaining nut. Opening the sensor Closing the sensor • Loosen the retaining nut until the cable slides easily into the...
75.5351.02 EN 20080317 (75.5350) Page 3 of 7 FALCON (Mounting height: 16.5 feet) The sensing fields here on the right correspond to the following adjustments: • tilt angle: 15°, 30°, 45° • sensitivity: 9. The sensing fields here on the right correspond to the following adjustments: • tilt angle: 30°...
75.5351.02 EN 20080317 (75.5350) Page 7 of 7 During the manual adjustment session: • Each press on the right button increases the number of the displayed parameter by one unit; • Each press on the left button increases the value of the displayed parameter by one unit. NOTE: When the maximum value or...