Page 2 - Tap options
Page 2 of 20 804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 Tap options Arc / Cube Tap Celsius Tap Classic Tap Elite Tap The HydroTap appliance series offers a range of interchangeable taps to suit the customer’s needs (See options below). For ease of installation, it is reco...
Page 3 - Index
804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 Page 3 of 20 HydroTap Specifications Installation check list .................................................................................................................... 4General product features ............................
Page 4 - Before Commissioning:; Installation checklist
Page 4 of 20 804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 Before Installation: A. Read the instructions and check if there is adequate space to mount all of the components. B. Note: Not all fittings are supplied with the appliance kit. Isolation valves and special tools are...
Page 5 - What is the Zip HydroTap ?; General Product Features
804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 Page 5 of 20 What is the Zip HydroTap ? The Zip HydroTaps are electronically controlled, filtered, Boiling, Chilled and Sparkling water, drinking systems for kitchens and tea rooms. The HydroTap units are under bench drinking wat...
Page 6 - Important Safety Instructions
Page 6 of 20 804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 Important Safety Instructions This manual contains important safety, Installation instructions for the Zip HydroTap G4. Safety This appliance is not intended for use by persons (including children) with reduced physi...
Page 7 - WARNINGS
804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 Page 7 of 20 Important Safety Instructions WARNINGS 1. The Zip HydroTap unit must be earthed. The resistance of the earth connection from each exposed metal part must be less than 1 ohm. 2. All Installation and service work must ...
Page 8 - Major components and accessories; Parts supplied; Technical Specifications
Page 8 of 20 804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 Major components and accessories Parts supplied Description 1 off 4 HydroTaps with hoses (Classic tap shown) 1 off HydroTap Undersink Unit with air and water filters 1 off Mains water connection hose Vent Kit 1 x Inl...
Page 9 - Before Installation; Note; Special Tools Required:; For the standard and Mixer taps:; Section1
804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 Page 9 of 20 Before Installation Before installing ensure that the following have been provided at the Installation site: • Review all the technical specifications. • Ensure the underbench can support the product weight when full...
Page 10 - Section 2
Page 10 of 20 804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 2.1 Ventilation for All Models Proper air circulation must be provided for all Boiling and Chilled models. The system will operate correctly only if the recommended air gaps are achieved during Installation. The min...
Page 11 - Ventilation; Airflow through the cupboard; Door outlet vent
804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 Page 11 of 20 Ventilation Air inlet vent position Airflow through the cupboard B D rd Cool air IN Warm air OUT Door outlet vent 1. Drill four pilot holes 12mm dia. 2. Finish the cutout using a jig saw and keyhole or Wall Board sa...
Page 12 - Typical Cut out procedure for; Cutout deatils; B D
Page 12 of 20 804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 Typical Cut out procedure for B Ventilation Cutout deatils Air inlet vent 1. Mark out and cut the air inlet and door outlet holes as shown 2. Ensure the air inlet vent and air outlet vent are positioned at opposite ...
Page 13 - Secure the cylinder mounting:
804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 Page 13 of 20 Section 3 CO 2 Cylinder WARNING: This cylinder mus be installed in an open plan area or in an enclosed room, with a volume no less than 20m 3 . If more than 1 gas cylinder containing CO 2 is present within the same ...
Page 14 - John Guest; Hose and tube fitting.; Connect the gas hose:; Installation
Page 14 of 20 804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 Section 4 Undersink Unit Installation John Guest fittings (Insertion and removal) Be careful when cutting the poly tube so that there are no rough edges and that the tube is not distorted. 1. Use a sharp knife to en...
Page 15 - After replacing a bottle or after mak-; Faulty seal joint; CO; Installation and connection
804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 Page 15 of 20 CO 2 pressure set zone: 2.7-3.0 bar IMPORTANT: 4.3 After replacing a bottle or after mak- ing a gas connection, check for gas leaks: Stage1: 1. Turn the gas OFF 2. Using soapy water applied with a sponge, or with a ...
Page 16 - Installation Instructions
Page 16 of 20 804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 Installation Instructions Note: - Mains hose length is 750mm- Plug and Cord length is 1800mm Position the under sink unit close to the outlet tap, within reach of the hose and cord lengths supplied Note: Note: All A...
Page 18 - Commissioning; Filter Flush
Page 18 of 20 804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 OPEN Position CLOSED Position ON OFF Stop cockoperation Commissioning NOTE: For any subsequent fi lter changes or any operational procedures, please refer to the HydroTap user guide, located inside the fi lter housi...
Page 19 - Trouble Shooting; System Fault; End of Life Disposal
804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 Page 19 of 20 Trouble Shooting System Fault Message Possible Cause Solutions Power board fault Electrical disruption Check power supply and all fuses Interface fault Internal fault Call Zip Service Level board fault Internal faul...
Page 20 - Contact Details; Head Office
Page 20 of 20 804052 - CS Residential- Installation Instructions - Sept 2016 - v3.01 Contact Details The standard cup referred to in this publication is 167 ml (6 fl oz). The standard glass is 200 ml (7 fl oz). The terms “Zip” and “HydroTap” are registered trade marks of Zip Heaters (Aust) Pty Ltd. ...