Page 3 - WARNINGS AND PRECAUTIONS; The appliance must be placed in an upright position.; Before installation
03 806143 - CW ChillTap UCCT 10.18 v1.03 WARNINGS AND PRECAUTIONS A. Read the instructions.B. Note: All fittings are supplied with the appliance kit except an isolation valve.C. Check the water quality to determine if extra filtration will be required.D. Check the appliance rating plate and ensure c...
Page 5 - Tap Installation; In addition to common tools, the following will be required:; Position the Tap; the length of the supplied tubing.; Installation instructions
05 806143 - CW ChillTap UCCT 10.18 v1.03 Tap Installation In addition to common tools, the following will be required: • 25mm (ChillTap Standard/Heavy Duty) OR 35mm (ChillTap Extra) diameter sheet metal hole punch for sink tops (not supplied) • 25mm (ChillTap Standard/Heavy Duty) OR 35mm (ChillTap E...
Page 6 - Clearance; Ventilation; Jigsaw and 12 mm drill.; Ventilation Requirements
06 806143 - CW ChillTap UCCT 10.18 v1.03 Installation instructions Clearance Envelope Ventilation When installing air flow ducts, the following tools will be required: • Jigsaw and 12 mm drill. • Keyhole or Wall Board saw. Ventilation Requirements IMPORTANT! Allow clearance of 50 mm around and 200 m...
Page 7 - Additional ventilation; Ensure that A and B are positioned at opposite; Vent tray
07 806143 - CW ChillTap UCCT 10.18 v1.03 Installation instructions = = max 43 314.00 12.00 12.00 285.00 12.00 5 326.00 A A - KICKBOARD CUT-OUT 1.Drill 4 pilot holes Ø12 in corners2.Finish cut-out using Jigsaw and Keyhole or Wall Board saw B - CABINET FLOOR CUT-OUT 1.Drill two pilot holes Ø122.Finish...
Page 8 - Chiller Installation; The tubing length is limited to 1000 mm.; Mains Water Connection; If caps are removed to allow lifting handles; Water Connection
08 806143 - CW ChillTap UCCT 10.18 v1.03 Installation instructions Chiller Installation Place the chiller unit into the cupboard with the proposed outlet tap position as close as possible, to minimise the length of tubing exposed between the chiller unit and the outlet tap. Arrange tubes in the most...
Page 9 - ChillTap Extra; Commissioning
09 806143 - CW ChillTap UCCT 10.18 v1.03 Installation instructions Hose Connections Note: To avoid water leaks, be careful not to damage the tubes. The tube must not be kinked around a bend, as the tube may contain water under pressure. If shortening the hoses, ensure ends are cut clean and square. ...
Page 10 - Operation & Maintenance; Operation; ROTATE; Water Filter; Air Inlet Screen; Slide to remove
10 806143 - CW ChillTap UCCT 10.18 v1.03 Operation & Maintenance Operation To dispense chilled, filtered water, rotate the lever on the right hand side of the carafe tap to a horizontal position. The lever will spring back when released. ChillTap Extra: Chilled still filtered water is dispensed ...
Page 12 - Head Office; Postal: Locked Bag 80
12 806143 - CW ChillTap UCCT 10.18 v1.03 AU02691 Head Office Zip Water (Aust) Pty. Ltd. ABN 46 000 578 727 67-77 Allingham Street Condell Park NSW 2200 Postal: Locked Bag 80 Bankstown 1885 Australia www.zipwater.com Telephone (02) 9796 3100 Sales Free Call: 1800 638 633 Service Free Call: 1800 460 2...