Page 2 - Contents
Page 2 of 20 804721- CS_ChillTap Sparkling 09.16 v1.00 Pre-Installation Notes . . . . . . . . . . . . . . . . . . . . . . . . . 3 Read These Warnings First . . . . . . . . . . . . . . . . . . . . 4 Product Specifications. . . . . . . . . . . . . . . . . . . . . . . . . 4 Section 1 - Tap Installation...
Page 3 - Pre-Installation Notes; Precautions
804721 - CS_ChillTap Sparkling 09.16 v1.00 Page 3 of 20 Pre-Installation Notes A. Read the instructions. B. Note: All fittings are supplied with the appliance kit except an isolation valve. C. Check the water quality to determine if extra filtration will be required. D. Check the appliance rating pl...
Page 5 - Installing the Tap; Special Tools
804721 - CS_ChillTap Sparkling 09.16 v1.00 Page 5 of 20 Section 1 Tap Installation Installing the Tap Position and install the carafe filler at the back of the sink or on the Font, where there is a minimum 52mm wide flat area within the draining area of the sink. Ensure the distance between the tap ...
Page 6 - Section 2; Bufer Pad
Page 6 of 20 804721- CS_ChillTap Sparkling 09.16 v1.00 2.1 - Ventilation Proper air circulation must be provided for all Chilled models. The system will operate correctly only if the recommended air gaps are achieved during Installation. The minimum requirement is for a 50mm air gap either side and ...
Page 8 - Ventilation; B D
Page 8 of 20 804721- CS_ChillTap Sparkling 09.16 v1.00 Typical Cut out procedure for B Ventilation Cutout details Air inlet vent 1. Mark out and cut the air inlet and door outlet holes as shown 2. Ensure the air inlet vent and air outlet vent are positioned at opposite ends of the same cupboard spac...
Page 9 - Secure the cylinder mounting:; Connect the gas hose:; OPEN
804721 - CS_ChillTap Sparkling 09.16 v1.00 Page 9 of 20 Section 3 CO2 Cylinder WARNING: This cylinder must be installed in an open plan area or in an enclosed room, with a volume no less than 20m3. If more than 1 gas cylinder containing CO2 is present within the same location, the recommended ventil...
Page 10 - CO2 Cylinder
Page 10 of 20 804721- CS_ChillTap Sparkling 09.16 v1.00 CO2 Cylinder 3.4 Test for gas leaks: Using soapy water perform a leak test. Turn the gas OFF. Apply the soapy water to the gas connections using a sponge or brush. Cover all of the gas joints with a liberal amount of suds. Turn ON the gas. Insp...
Page 12 - Undersink Unit Installation; - Chiller Installation; Mains Connection
Page 12 of 20 804721- CS_ChillTap Sparkling 09.16 v1.00 Undersink Unit Installation Note: To avoid water leaks, take care when bending rigid plastic tubing. The tube must not be kinked or crushed around a bend, as the tube may containing water under pressure. Therefore be careful not to nick, scratc...
Page 14 - Important
Page 14 of 20 804721- CS_ChillTap Sparkling 09.16 v1.00 Section 5 Commissioning Chilled filtered water (blue) Sparkling filtered water (white) ROTATE 5.1 - Test and Commission: Do NOT turn power or water on to the unit. The carbonator must be purged first with the CO2 gas. Failure to do so will resu...
Page 15 - Adjusting the fl ow rate; Commissioning
804721 - CS_ChillTap Sparkling 09.16 v1.00 Page 15 of 20 5.2 Adjusting the fl ow rate The carbonation valve has an adjustable fl ow rate. The optimum setting for the valve is 1.6 litres per minute. Using a 6mm Allen key or a large fl at blade screw driver, you can adjust the fl ow on the valve. 1. A...
Page 16 - Water Filter Replacement; Warning
Page 16 of 20 804721- CS_ChillTap Sparkling 09.16 v1.00 Section 6 Maintenance 6.1 Water Filter Replacement NOTE: For safe operation, the filter cartridge should be replaced every 6-12 months, or earlier if you notice a persistent reduction in water pressure from the appliance or an unpleasant taste ...
Page 17 - Gas Bottle Replacement:; Service; Maintenance
804721 - CS_ChillTap Sparkling 09.16 v1.00 Page 17 of 20 6.3 Gas Bottle Replacement: 1. Turn off the water and power supply to the chilled sparkling unit.2. Turn off the regulator on top of the bottle. The regulator has a left hand thread, to turn off, turn anticlockwise until shut. 3. Remove the CO...
Page 18 - Trouble Shooting
Page 18 of 20 804721- CS_ChillTap Sparkling 09.16 v1.00 Symptom Possible Cause Responsibility Solution No still water No sparkling water Poor levels of carbonation in drinks Mains water not connected or turned on Water pressure regulator failed Unit frozen up No CO2 pressure Internal fault Water tem...
Page 20 - Contact Details; Head Office
804721 ChillTap Sparkling 09.16 v1.0 WMKA21821 ATS 5200.105 Contact Details Head Office Zip Heaters (Aust) Pty. Ltd.ABN: 46 000 578 72767 Allingham StreetCondell Park NSW 2200 Postal: Locked Bag 80Bankstown 1885 Australia Website: www.zipwater.com Facsimile: (02) 9796 3858Telephone: (02) 9796 3100 S...