York FC35B - Installation Manual
York FC35B Heat Pump – Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – SECTION II: GENERAL INFORMATION; INSPECTION
- Page 3 – Dimensions - FC Coils; BOTTOM OPENING; Dimensions - PC Coils
- Page 4 – LIMITATIONS; SECTION III: COIL METERING DEVICES; DUCT FLANGES; Coil Air Flow Limits; NOTICE
- Page 5 – FURNACE ASSEMBLY - PC; COIL SIZE
- Page 6 – CRITICAL COIL PROJECTION; SECTION V: DUCT CONNECTIONS; DO NOT; use Teflon; sealant may cause damage and premature failure of the drain pan.; SUCTION FEEDER TUBE CONDENSATE; Equipment should never be operated without filters.; Condensate Deflector on Vertical Drain Pan
- Page 7 – Connect lines as follows:; Purge refrigerant lines with dry nitrogen.; SECTION VIII: COIL CLEANING; Condensate; Air Flow Data - Static Pressure Drop; Coil Size
- Page 8 – Copyright; York International Corp.; SECTION X: INSTALLATION; Pressure Check; Was the coil still under pressure when received?; TXV Check List; Is coil metering device installed correctly?; Was the correct TXV installed per the outdoor unit instructions?; Location of Trapped and Plugged Drain Connections; Trapped; Horizontal Drain Conditions; Were all drains trapped or plugged?; Trap Appropriate Side
900588-UIM-C-0214
FULL-CASED MULTI-POSITION FOR
COOLING/HEAT PUMPS
MODELS: MC
FULL-CASED UPFLOW/COUNTERFLOW FOR
COOLING/HEAT PUMPS
MODELS: FC
PARTIAL-CASED UPFLOW FOR COOLING/HEAT PUMP
MODELS: PC
ISO 9001
Certified Quality
Management System
INSTALLATION MANUAL
LIST OF SECTIONS
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
COIL METERING DEVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
COIL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
DUCT CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CONDENSATE DRAIN CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . .6
REFRIGERANT LINE CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . .7
COIL CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
AIR SYSTEM ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
INSTALLATION VERIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
LIST OF FIGURES
Component Location - Coil MC & FC . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Component Location - Coil PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
TXV Bulb Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Proper Bulb Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Duct Flanges - Coil FC/MC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Vertical Applications with Furnaces . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Horizontal Right Application with Furnaces . . . . . . . . . . . . . . . . . . . . . 5
Horizontal Left Application with Furnaces . . . . . . . . . . . . . . . . . . . . . . 5
Upflow - PC Coil Installation with Furnace . . . . . . . . . . . . . . . . . . . . . .5
Condensate Deflector on Vertical Drain Pan . . . . . . . . . . . . . . . . . . . .6
Condensate Deflector on Horizontal Drain Pan Edge . . . . . . . . . . . . .6
S-Clip Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Pressure Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
TXV Check List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Drain Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Location of Trapped and Plugged Drain Connections . . . . . . . . . . . . .8
LIST OF TABLES
Dimensions - MC Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Dimensions - FC Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Dimensions - PC Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Coil Air Flow Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Coil Projection Dimensions - PC Coils . . . . . . . . . . . . . . . . . . . . . . . . .5
Air Flow Data - Static Pressure Drop . . . . . . . . . . . . . . . . . . . . . . . . . .7
SECTION I: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words
DANGER
,
WARNING
, or
CAUTION
.
DANGER
indicates an
imminently
hazardous situation, which, if not
avoided,
will result in death or serious injury
.
WARNING
indicates a
potentially
hazardous situation, which, if not
avoided,
could result in death or serious injury
.
CAUTION
indicated a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury. It is also used to alert
against unsafe practices and hazards involving only property damage.
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage. Refer to this manual for assis-
tance or additional information, consult a qualified installer or service
agency.
This product must be installed in strict compliance with the enclosed
installation instructions and any applicable local, state, and national
codes including, but not limited to building, electrical, and mechanical
codes.
The furnace area must not be used as a broom closet or for any other
storage purposes, as a fire hazard may be created. Never store items
such as the following on, near or in contact with the furnace.
1. Spray or aerosol cans, rags, brooms, dust mops, vacuum
cleaners or other cleaning tools.
2. Soap powders, bleaches, waxes or other Cleaning com-
pounds; plastic items or containers; gasoline, kerosene, ciga-
rette lighter fluid, dry cleaning fluids or other volatile fluid.
3. Paint thinners and other painting compounds.
4. Paper bags, boxes or other paper products
Never operate the furnace with the blower door removed. To do so
could result in serious personal injury and/or equipment damage.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- York
- Model
- FC35B
- Document type
- Installation Manual
- Category
- Heat Pump
- Language(s)
- English
- Pages
- 8
- Format
Summary
900588-UIM-C-0214 2 SECTION II: GENERAL INFORMATION This instruction covers the installation of the following coils with 80+ or90+ AFUE furnaces or MA/MX/MV air moving systems. The coils have sweat connect fittings. All coils are shipped with a lowpsi nitrogen holding charge. INSPECTION As soon as a...
900588-UIM-C-0214 3 TABLE 2: Dimensions - FC Coils Models Dimensions 1 Refrigerant Connections 2 Height Width Opening Widths Line Size A B C D Liquid Vapor FC18A 18 14-1/2 13-3/8 13-1/2 3/8 3/4 FC18B 18 17-1/2 16-3/8 16-1/2 FC24A 22 14-1/2 13-3/8 13-1/2 FC24B 22 17-1/2 16-3/8 16-1/2 FC30A 22 14-1/2 ...
900588-UIM-C-0214 4 LIMITATIONS These coils should be installed in accordance with all national and localsafety codes. SECTION III: COIL METERING DEVICES An orifice or a TXV to be installed in the field. Refer to installation man-ual with TXV kit. It is recommended to install the orifice or TXV kit ...