York BHP024 - Manual

York BHP024

York BHP024 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 2 – Unitary Products Group
  • Page 3 – 36-21528-007-A-1205; FIELD-INSTALLED ACCESSORIES
  • Page 5 – FIGURE 1 - UNIT CUT AWAY; TABLE 2: PHYSICAL DATA; MODELS
  • Page 15 – TABLE 16: ADDITIONAL STATIC RESISTANCE
  • Page 16 – FIGURE 2 - FIELD WIRING DIAGRAM
  • Page 19 – TABLE 19: APPLICATION DATA; FIGURE 4 - UNIT CLEARANCES; CLEARANCES; UNIT CLEARANCES
  • Page 20 – FIGURE 5 - UNIT DIMENSIONS
  • Page 21 – FIGURE 6 - TYPICAL APPLICATIONS
  • Page 22 – FIGURE 7 - ROOF CURB DIMENSIONS
  • Page 26 – MECHANICAL SPECIFICATIONS; GENERAL DESCRIPTION
  • Page 27 – Solid-core filter dryer to eliminate any foreign matter.; ELECTRIC HEATING SECTION
Loading the manual

036-21528-007-A-1205

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

®

AFFINITY™ SERIES

SINGLE PACKAGE
HEAT PUMPS

BHP024 THRU 060
2 THRU 5 NOMINAL TONS
13 SEER

FACTORY MOUNTED TXV

DESCRIPTION

York

®

Affinity™ Series packaged heat pumps are designed

for outdoor installation. Only utility and duct connections
are required at the point of installation.

Field-installed electric heater accessories are available to
provide electric heat, if required.

STANDARD FEATURES / BENEFITS

OPERATING EFFICIENCY

All units provide high operating efficiencies of 13 SEER, 3.3
COP or greater, and 7.7 HSPF. All efficiencies exceed leg-
islated minimum levels.

ON SITE FLEXIBILITY

All model sizes share a common, compact design cabinet
with a single footprint. The installer has the flexibility of set-
ting one curb or pad and placing the proper tonnage unit
after the internal load has been determined. Field convert-
ible duct connections, from side shot to down shot, allows
the installer greater flexibility and the need to carry less
inventory.

LOWER INSTALLATION COST

Installation time and costs are reduced by easy power and
control wiring connections. The small base dimension
means less space is required on the ground or roof. Plus,
the installer can fit this unit between the wheel wells of full
size pick-up truck. All models are under 500 pounds.

All units are completely wired, charged with R-22 and
tested prior to shipment. Unique test stations, are used to
insure product quality. Refrigerant charge, and component
part numbers are verified via computers at manufacturing
point. Vital run test statistics, such as, system pressure,
motor currents, air velocity and temperature unit vibration
are monitored and recorded by the system to insure unit
performance.

Equal size, side supply and return duct connections allow
easy hook-up of ducts to match low crawl spaces without
transition pieces.

UTILITY CONNECTIONS MADE EASY

Electrical utility knockouts are provided through the bottom,
as well as the side of the unit. Utility connections can be
made quickly and with a minimum amount of field labor. A
field supplied and field installed electrical disconnect
switch must be installed.

CONVERTIBLE AIRFLOW DESIGN

The bottom duct openings are covered when they leave the
factory. They are ready for a side supply / side return appli-
cation. If a bottom supply / bottom return application is
desired, you simply remove the two panels from the bottom
of the unit and place them in the side supply / side return
duct openings. No panel cutting is required and no acces-
sory panel is necessary. Convertible airflow design allows
maximum field flexibility and minimum inventory.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Unitary Products Group

036-21528-007-A-1205 2 Unitary Products Group CONDENSATE PAN A non-corrosive, long-lasting, water-tight pan is posi-tioned below the evaporator coil to collect and drain all condensate; less collection of stagnate condensate will build-up. The condensate pan conforms to ASHRAE 62-89 standards (Venti...

Page 3 - 36-21528-007-A-1205; FIELD-INSTALLED ACCESSORIES

036-21528-007-A-1205 Unitary Products Group 3 PROTECTED COMPRESSOR The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compres-sor, if undesirable op...

Page 5 - FIGURE 1 - UNIT CUT AWAY; TABLE 2: PHYSICAL DATA; MODELS

036-21528-007-A-1205 Unitary Products Group 5 SEER =Seasonal Energy Efficiency Ratio - the total cooling output in BTU's during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. COP = Coefficient of Performance - the total heatin...

Other York Models

All York Other