York YMB-HW - Manual

York YMB-HW

York YMB-HW – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – INSTALLATION; FIG. 1 – UNIT NOMENCLATURE; • Engineering Guide, Direct Drive YMB Models; MODEL; HW
  • Page 4 – FIG. 4 – STANDARD LOW VOLTAGE WIRING
  • Page 6 – PIPING; (see table 3 for connection; PIPING PRECAUTIONS
  • Page 7 – FAN COILS START-UP CHECKLIST; INSTALL CHECKLIST
  • Page 8 – MAINTENANCE; MOTOR; CLEAN UNIT INTERIOR
Loading the manual

L23954Y 1-05

INSTALLATION, OPERATION, & MAINTENANCE

FAN COIL

AIR CONDITIONERS

NEW RELEASE

Form 115.20-NOM4 (105)

***** WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER *****

Altering the product or replacing parts with non-authorized factory parts voids all warranty or

implied warranty and may result in adverse operational performance and/or a possible hazardous

safety condition to service personnel and occupants. Company employees and/or contractors are

not authorized to waive this warning.

Notes:

1. For proper operation, control valve must be normally closed.
2. Aquastats provided where required.
3. Electric Heat is only available in the YMBE series. These units require a remote thermostat (low voltage 4 wire thermostat).

MODELS:

YMB, YMB-HW, YMBE

YMB

Series

(2-pipe, cooling and heating)

(Replaces the MH Series)

YMB-HW

Series

(4-pipe, cooling and heating)

(Replaces the MH-HW Series)

YMBE

Series

(2-pipe, cooling with electric heat)

(Replaces the MHE Series)

LD07966

00781VIP

(See page 3 for details)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; FIG. 1 – UNIT NOMENCLATURE; • Engineering Guide, Direct Drive YMB Models; MODEL; HW

YORK INTERNATIONAL 2 FORM 115.20-NOM4 (105) 3 YORK INTERNATIONAL INSTALLATION FORM 115.20-NOM4 (105) TABLE OF CONTENTS FIG. 1 – UNIT NOMENCLATURE �� � �� ��� ���� ��� ������� � � ��� ��� �� � ���� ����� � ���� ����� � ���� ����� � ���� ��� ���� ����� ���� ����� ���� �������� � � � ���������� �������...

Page 4 - FIG. 4 – STANDARD LOW VOLTAGE WIRING

YORK INTERNATIONAL 4 FORM 115.20-NOM4 (105) INSTALLATION 5 YORK INTERNATIONAL INSTALLATION FORM 115.20-NOM4 (105) FIG. 2 – YMBE WIRING CONNECTIONS, 15 & 20 KW FIG. 4 – STANDARD LOW VOLTAGE WIRING FIG. 5 – T200 THERMOSTAT W/CONTROLLER OPTION ��� ������� � �� � �� ��� ������� � �� � �� ��� �������...

Page 6 - PIPING; (see table 3 for connection; PIPING PRECAUTIONS

YORK INTERNATIONAL 6 FORM 115.20-NOM4 (105) INSTALLATION 7 YORK INTERNATIONAL FORM 115.20-NOM4 (105) PIPING The supply and return piping must be adequately sized to meet the design water flow requirements as specified for the specific installation (see table 3 for connection sizes). All chilled wate...