Xantech RC68+ - Manual
Xantech RC68+ – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – COMMAND DEFINITIONS; that come with each specific Xantech model.; F r o n t; RC68+ Itemized Functions and Features
- Page 4 – CODE GROUP SETTING PROCEDURES; Use these procedures to:; Setting the RC68+ Code Group Number; specific Xantech model.; in the number and the Right switch is the second digit.; Do not connect other Xantech models at this time.; Setting the code switches (68 shown for the ZPR68)
- Page 5 – Amplifiers & Preamplifiers; rear; Switches set to; FF; for Code Group changes.
1
Amplifiers & Preamplifiers
RC68+
INSTALLATION INSTRUCTIONS
RC68+
PROGRAMMER / REMOTE CONTROL
The RC68+ programmer is a 55 key hand-held device that generates all the IR
codes necessary for the set up and operation of Xantech IR remote controlled
products. Such products include models ZPR68, RAT1, MIRV1, GATEKEEP-IR,
etc. The RC68+ is an upgrade of the previous 32 key RC68. While providing
additional key-code command capabilities, it retains all previous RC68 program-
ming in a similar 32 key layout section on the keypad.
GENERAL
• The RC68+ is used initially for the setup of system control parameters and IR
Code Groups for Xantech products.
• It is then used to "teach" a basic set of operational IR commands into universal
learning devices such as the Xantech URC series learning remotes, the
Xantech Smart Pads, the 590 Programmable Controller, the 710 Fone Link,
etc., for the end user.
• Included with the RC68+ is a set of keypad overlays. These overlays are marked
with command names that apply to specific Xantech models. They are provided
to make it easier for the installer when setting up the system. See
Fig. 2
and
the model listings below.
• While the RC68+ will operate as a separate remote control, it is highly
recommended it not be given to the final user for the following reasons:
• Since it includes special setup codes, the user may inadvertently alter the
installer configurations.
• Also, since the user will require IR commands from other brands of equipment to control the total system,
in addition to those of the RC68+, all commands should be consolidated into one learning device, for ease
of use.
THE RC68+ OVERLAY SYSTEM
• The RC68+ base unit comes with a permanently attached keypad overlay (A) with lettering that identifies
the commands for operation of the model ZPR68 and other models with similar commands.
• Additional temporary overlays are included for use with
Xantech models that differ greatly from the ZPR68.
• The overlays are simply placed over the RC68+ keys, as
needed. Use the overlay that corresponds to the Xantech
model or models you are working with, as listed below.
Xantech Model
RC68+ Overlay Id Letter
RAT1, MIRV1, ............................................ A
(permanently attached
RGC11, RP41AV, to the RC68+)
RS41AV, ZPR68,
ZPR68-10
AC2, CC12, SR21 ...................................... B
RT8, RT16-10 ............................................ C
680-10, 686-10, CC62 ............................... D
Gatekeep-IR Modules ................................ E
IR-DC4 (RC68+ IR-to-RS232, Arrakis) ...... F
SmartPad
3
.................................................. I
A
6 0
8 8
A 8
9 8
A
B
C
ADJ-OFF
1
2
3
4
5
6
7
8
GLOBAL
Z-ADJ
TREBLE
VOL
MUTE
ON
OFF
E-FLAT
LAST
MAX-V
TRIM
OFF
C-BAL
BASS
INPUT
8 0
4 8
1 0
9 0
0 1
0 0
C 0
5 0
D 0
4 1
4 0
A 0
2 1
2 0
E 0
7 0
F 0
6 1
1 8
0 9
B 8
2 9
2 8
E 8
7 8
F 8
6 9
6 8
C 8
5 8
D 8
4 9
E 1
8 9
C 9
A 9
E 9
7 1
1 9
5 9
3 9
7 9
F 1
9 9
D 9
B 9
F 9
0 8
3 8
3 0
B 0
RC68+ PROGRAMMER
Permanently
attached
"A" Overlay.
A
B
C
ADJ-OFF
1
2
3
4
5
6
7
8
GLOBAL
Z-ADJ
TREBLE
VOL
MUTE
ON
OFF
E-FLAT
LAST
MAX-V
TRIM
OFF
C-BAL
BASS
INPUT
RC68+ PROGRAMMER
OFF
ON
TGL
MMT
OFF
ON
TGL
MMT
OFF
ON
TGL
MMT
OFF
ON
TGL
MMT
OFF
ON
TGL
MMT
OFF
ON
TGL
MMT
OFF
ON
TGL
MMT
OFF
ON
TGL
MMT
B
0
2
3
4
5
6
1
7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
GP-ON
GP-OFF
C
OFF
ON
TGL
MMT
OFF
ON
TGL
MMT
OFF
ON
TGL
MMT
OFF
ON
TGL
MMT
OFF
ON
TGL
MMT
OFF
ON
TGL
MMT
GP-ON
GP-OFF
D
1
3
4
5
6
2
ON
OFF
OPEN
CLOSE
ON
OFF
OPEN
CLOSE
ON
OFF
OPEN
CLOSE
ON
OFF
OPEN
CLOSE
ON
OFF
OPEN
CLOSE
ON
OFF
OPEN
CLOSE
ON
OFF
OPEN
CLOSE
ON
OFF
OPEN
CLOSE
E
1
3
4
5
6
7
8
2
1
2
3
PLAY
4
5
6
STOP
7
8
9
PAUSE
CD#
0
TR#
RESUME
DISC --
DISC +
TR --
TR +
1 CD
ALL CD
SEQL RANDOM
ARTIST
TITLE
NUMBER ZONE
LEFT
RIGHT
ENTER SELECT
F
1
3
4
5
6
7
8
2
ON/TOG
OFF
0
ON/TOG
OFF
1
ON/TOG
OFF
2
ON/TOG
OFF
3
ON/TOG
OFF
4
ON/TOG
OFF
5
ON/TOG
OFF
6
ON/TOG
OFF
7
ON/TOG
OFF
8
ON/TOG
OFF
9
ON/TOG
OFF
A
ON/TOG
OFF
B
ON/TOG
OFF
C
ON/TOG
OFF
D
ON/TOG
OFF
E
ON/TOG
OFF
F
I
Overlay
Identification
Letter
A
FIG. 2
Overlays for the RC68+ Programmer
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 RC68+ COMMAND DEFINITIONS • For detailed information that defines the button commands relating to each overlay, refer to the Installation Instructions that come with each specific Xantech model. • The only exception to this is for the model ZPR68; complete command definitions for it are included...
4 RC68+ CODE GROUP SETTING PROCEDURES Use these procedures to: a) Select the Code Group Number on the RC68+ to match the Code Group Number internally preset at the factory for the specific Xantech model you wish to control. b) Change the Internal Code Group Number of a Xantech model. You would do ...
5 Amplifiers & Preamplifiers RC68+ 2. Using a small blade screwdriver, rotate each of the two Code Group Setting Switches on the rear of the RC68+ to the F position ( FF ). See Fig. 5 . 3. Turn the remote over and locate a Code Group number that is different than any other Xantech model used i...