Controllers
INSTALLATION INSTRUCTIONS
590-00
PROGRAMMABLE CONTROLLER
FRONT PANEL
The front panel of the 590 is made of acrylic plastic. It should be cleaned with a soft cloth as it scratches
easily. Behind the panel are five red LEDs and an infrared sensor.
RED LEDs
ERROR - Lights when an error occurs in the learning process or when trying to send an
unprogrammed command.
PROGRAM - Lights when the PGM (program) button on the rear panel is pressed.
CONFIRM - Lights after a command has been memorized during programming.
DELETE - Blinks on and off when the DELETE button on the rear panel is pressed.
OUTPUT - Lights to indicate when infrared commands are being sent in response to a contact
closure. Contact closure is the most common form of input to the 590. If other types of inputs are
used, they will perform the same function as contact closures.
INFRARED SENSOR
Receives IR commands for programming the 590. It is located about one-half inch above the OUTPUT lamp.
1
12VDC
12VDC
1 2 3 4
BANK
RES DEL SEQ PGM
+
–
2
3
4
5
6
7
8
9 10 11
14 15 16 O G
–
+
12 13
ON
1 2 3 4
REAR PANEL
The following connectors, push-buttons and controls are located on the rear panel:
12VDC
jack – the power supply plugs in here (center conductor is positive).
BUTTONS
(Recessed - press with a pencil point or narrow blade screw driver).
RES - Reset - erases all stored commands.
DEL - Delete - allows erasure of selected commands.
SEQ - Sequence - begins and ends sequence mode programming.
PGM - Program - begins and ends learning mode.
BANK
- Bank DIP Switch – Selects one of four memory banks on microprocessor.
CONFIRM
DELETE
PROGRAMMABLE CONTROLLER
PROG
RAM
ERROR
O
UTPUT
590
Infrared Sensor
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 590-00 SCREW TERMINALS Opto-Isolator Inputs - 16 pairs of positive and negative terminals, isolated from ground. O - Infrared Output - Positive terminal for the IR output signal. G - Ground - Negative terminal for the IR output signal. The " O " and " G " terminals drive IR emitt...
3 Controllers 590-00 3. Press and hold down the key for the 590 input into which you wish to store the command. Remember, the " key " may be a contact closure push-button device, such as the Xantech 598 keypad (Fig. 1), or a simple jumper wire, one end connected to the" + " 12VDC t...
4 short tap for its command to be properly executed, then only a short burst of it should be stored in the 590.Step 4 would, therefore, be modified as follows: 4. Press the key on the remote controller that you wish to store. Hold the key for a very short period oftime or only as long as you usual...