Table of Contents:

  • Page 2 – Vermont Castings DVR28 Direct Vent Gas Fireplace; PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS; Table of Contents; Installation & Operating Instructions
  • Page 3 – PLEASE REVIEW THE FOLLOWING CAREFULLY; Certified To; Vented Gas Fireplace Heaters; Proposition 65 Warning:; Fuels used in gas, woodburning or
  • Page 4 – DVR28 Fireplace Dimensions; Fireplace specifications and framing dimensions.; Minimum Side Wall Clearance; Minimum clearances.
  • Page 5 – Locating Your Fireplace; Locate gas fireplace.; Appliance; Clearance to Combustibles; CAUTION: DO NOT place fireplace on floor; Secure wall mounting bracket in desired location.
  • Page 6 – Secure fireplace to wall mounting bracket.; High Elevations; Inlet Minimum; Gas Inlet and Manifold Pressures; Natural; Recommended gas line installation.; Air; open; Gas Specifications
  • Page 7 – Restrictor Plate Installation; Some installations may require some adjust-; Installation; Remove front glass assembly. Refer to Window; Examples for Extended Run/Restrictor Plate Settings; Install restrictor plate for optimum flame appearance.; DVR28 wiring diagram.; Wireless Remote
  • Page 8 – If vent termination is installed in an accessible loca-; General Venting; There must not be any obstruction
  • Page 9 – General Venting Information - Termination Location; Canadian Installations
  • Page 10 – Termination clearances.; General Information Assembling Vent Pipes; Canadian Installations:; Termination Clearances; of Caps; Twist Lock Pipes
  • Page 11 – How to Use the Vent Graph; Horizontal dimension from the outside face of the; ertical dimension from the fl; rear vent no elbows; Rear Vent Top View
  • Page 12 – Combustible Walls; Hole opening must; Adjustable zero clearance sleeve.; Vent Opening for Combustible Wall; Locate vent opening on wall.; Rear Wall Installation
  • Page 13 – Vertical Sidewall Applications; Maximum vent run with elbows.; According to the vent graph (Page 11) the; Total angular variation = 270°; Maximum elbow usage.
  • Page 14 – Below Grade Installations; Below grade installation.
  • Page 16 – Minimum termination to roof clearance.
  • Page 17 – Elbow; Vent components; Vent Components; Vent components; Venting Components; Venting Components; vent components
  • Page 18 – Glass Information; Care must be taken to avoid breakage of the glass.; Operating Instructions; Window Frame Assembly Removal; Remove front trim face by tilting bottom out and lift-; Window frame assembly removal.; Glass Cleaning; Hang Curve Face in place.
  • Page 19 – Flame & Temperature Adjustment; Flame adjustment for American Flame valve.; Correct DVR28 flame. Center flame should be ap-
  • Page 20 – Lighting & Operating Instructions; For Your Safety, Read the Following Warnings; result, causing property damage, personal injury and loss of life.; Lighting Instructions; DO NOT; Valve in the; “ON”; position
  • Page 21 – Troubleshooting
  • Page 22 – Troubleshooting AF4000 Valve; Pilot will not light/stay lit; A proper ground is essential to spark; Figure 39: Wall Transmitter Face
  • Page 23 – Verify the gas supply is turned on.; Main flame will not light; Figure 40: Battery Pack - Battery Compartment
  • Page 24 – Burner and Burner Compartment; Cleaning the Standing; If repair is necessary, it should be per-; Maintenance
  • Page 26 – Optional Accessories; Curve Face Kit; Color; Rustic Bronze
  • Page 27 – IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty,; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
  • Page 28 – CFM Corporation; Efficiency Ratings; Model
Loading the manual

DO NOT STORE OR USE GASOLINE OR
OTHER FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS OR ANY
OTHER APPLIANCE.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch; do not use

any phone in your building.

Immediately call your gas supplier from your

neighbor’s phone. Follow the gas suppliers

instructions.

If you cannot reach your gas supplier call the

fire department.

WARNING!

IF THE INFORMATION IN THIS MANUAL IS NOT
FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.

PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

INSTALLER/CONSUMER SAFETY INFORMATION

FOR YOUR SAFETY
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.

Direct Vent Model:
DVR28IN

Installation Instructions and Homeowner’s Manual

20012301 5/07 Rev. 1

� � � � � � � � �

�������

����������

INSTALLER: Leave this manual with the appliance CONSUMER: Retain this manual for future reference.

�����
�����������
����

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Vermont Castings DVR28 Direct Vent Gas Fireplace; PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS; Table of Contents; Installation & Operating Instructions

2 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace.IMPORTANT: Read all instructions and warnings carefully before starting installat...

Page 3 - PLEASE REVIEW THE FOLLOWING CAREFULLY; Certified To; Vented Gas Fireplace Heaters; Proposition 65 Warning:; Fuels used in gas, woodburning or

20012301 3 Vermont Castings DVR28 Direct Vent Gas Fireplace This gas appliance must be installed by a qualified installer, preferably NFI or WETT (Canada) certified, in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA...

Page 4 - DVR28 Fireplace Dimensions; Fireplace specifications and framing dimensions.; Minimum Side Wall Clearance; Minimum clearances.

4 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace DVR28 Fireplace Dimensions Fig. 1 Fireplace specifications and framing dimensions. Finished Wall Finished Wall 1“ (25 mm) Min. 12” (305 mm) Min. 12301DVR28 specs3/07 28” (711 mm) 19 ��� ” (492 mm) 6 ��� ” (162 mm) 15 ���� " (395 mm) 14 �...

Other Vermont Casting Models