Page 2 - Vermont Castings DVR28 Direct Vent Gas Fireplace; PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS; Table of Contents; Installation & Operating Instructions
2 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace.IMPORTANT: Read all instructions and warnings carefully before starting installat...
Page 3 - PLEASE REVIEW THE FOLLOWING CAREFULLY; Certified To; Vented Gas Fireplace Heaters; Proposition 65 Warning:; Fuels used in gas, woodburning or
20012301 3 Vermont Castings DVR28 Direct Vent Gas Fireplace This gas appliance must be installed by a qualified installer, preferably NFI or WETT (Canada) certified, in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA...
Page 4 - DVR28 Fireplace Dimensions; Fireplace specifications and framing dimensions.; Minimum Side Wall Clearance; Minimum clearances.
4 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace DVR28 Fireplace Dimensions Fig. 1 Fireplace specifications and framing dimensions. Finished Wall Finished Wall 1“ (25 mm) Min. 12” (305 mm) Min. 12301DVR28 specs3/07 28” (711 mm) 19 ��� ” (492 mm) 6 ��� ” (162 mm) 15 ���� " (395 mm) 14 �...
Page 5 - Locating Your Fireplace; Locate gas fireplace.; Appliance; Clearance to Combustibles; CAUTION: DO NOT place fireplace on floor; Secure wall mounting bracket in desired location.
20012301 5 Vermont Castings DVR28 Direct Vent Gas Fireplace A) Flat on wall B) Cross corner C) **Island D) *Room divider E) *Flat on wall corner F) Chase installation Y) 6” minimum NOTE: (Fig. 4) ** Island (C) and Room Divider (D) installation is possible as long as the horizontal portion of the ven...
Page 6 - Secure fireplace to wall mounting bracket.; High Elevations; Inlet Minimum; Gas Inlet and Manifold Pressures; Natural; Recommended gas line installation.; Air; open; Gas Specifications
6 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace �������������������������� Sheet Metal Screws (8) Sheet Metal Screws (4) FP1785 Wall Mounting Bracket Secured to Walll DVR28 Fig. 6 Secure fireplace to wall mounting bracket. High Elevations Input ratings are shown in BTU per hour and are ce...
Page 7 - Restrictor Plate Installation; Some installations may require some adjust-; Installation; Remove front glass assembly. Refer to Window; Examples for Extended Run/Restrictor Plate Settings; Install restrictor plate for optimum flame appearance.; DVR28 wiring diagram.; Wireless Remote
20012301 7 Vermont Castings DVR28 Direct Vent Gas Fireplace Restrictor Plate Installation The DVR28IN is shipped with a restrictor plate for ex-tended pipe runs other than straight out installations. A guide for usage is shown in Figure 10. NOTE: Some installations may require some adjust- ment by t...
Page 8 - If vent termination is installed in an accessible loca-; General Venting; There must not be any obstruction
8 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace Your fireplace is approved to be vented either through the side wall, or vertically through the roof. • Only CFM Corporation venting components specifi-cally approved and labelled for this fireplace may be used. • If vent termination is instal...
Page 9 - General Venting Information - Termination Location; Canadian Installations
20012301 9 Vermont Castings DVR28 Direct Vent Gas Fireplace V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINATION AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED H I ����� ������ Operable Operable Fixed Closed V B CFM145aDV Termin Location5/01/01 Rev. 12/05/01 sta INSIDE CORNER DETA...
Page 10 - Termination clearances.; General Information Assembling Vent Pipes; Canadian Installations:; Termination Clearances; of Caps; Twist Lock Pipes
10 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace Fig. 12 Termination clearances. General Information Assembling Vent Pipes Canadian Installations: Venting system must be installed in accordance with the current CSA-B149.1 installation code. USA Installations: The venting system must conf...
Page 11 - How to Use the Vent Graph; Horizontal dimension from the outside face of the; ertical dimension from the fl; rear vent no elbows; Rear Vent Top View
20012301 11 Vermont Castings DVR28 Direct Vent Gas Fireplace The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system.1. Determine the height of the center of the horizont...
Page 12 - Combustible Walls; Hole opening must; Adjustable zero clearance sleeve.; Vent Opening for Combustible Wall; Locate vent opening on wall.; Rear Wall Installation
12 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace STEP 1 Locate vent opening on the wall. To locate hole center consult with appropriate fireplace dimensions, Page 4. Frame as shown below. Combustible Walls (Fig. 17) : Cut a 10 ³⁄₈ ”H x 9 ³⁄₈ ” W (264 x 240 mm) hole through the exterior wa...
Page 13 - Vertical Sidewall Applications; Maximum vent run with elbows.; According to the vent graph (Page 11) the; Total angular variation = 270°; Maximum elbow usage.
20012301 13 Vermont Castings DVR28 Direct Vent Gas Fireplace Vertical Sidewall Applications Since it is very important for the venting system to maintain balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered...
Page 14 - Below Grade Installations; Below grade installation.
14 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace Below Grade Installations When it is not possible to meet the required vent ter-minal clearances of 12” (305 mm) above grade level a snorkel kit is recommended. This allows installation depth of down to 7” (178 mm) below grade level. The 7...
Page 16 - Minimum termination to roof clearance.
16 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace TWL101aTwist Lock Pipe2/8/99 djt 3 #5 Sheet Metal Screws per Joint Sealant TWL101a Fig. 30 Roof flashing. Storm Collar Min.2' (610 mm) FP1185 Fig. 29 Minimum termination to roof clearance.
Page 17 - Elbow; Vent components; Vent Components; Vent components; Venting Components; Venting Components; vent components
20012301 17 Vermont Castings DVR28 Direct Vent Gas Fireplace 7TDVRVT - Through the wall Rear Vent Termination Starter Kit - Model 7TDVSK - Sidewall Venting (Twist Lock Pipe) Model 7FDVSK - Sidewall Venting (Flex Vent Pipe) Models 7TDVTK/TV - Hot Touch Termination Kits Model 7TDVTVTK/TV - Cool Touch ...
Page 18 - Glass Information; Care must be taken to avoid breakage of the glass.; Operating Instructions; Window Frame Assembly Removal; Remove front trim face by tilting bottom out and lift-; Window frame assembly removal.; Glass Cleaning; Hang Curve Face in place.
18 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace Glass Information Only glass approved by CFM Corporation should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass. • Do not opera...
Page 19 - Flame & Temperature Adjustment; Flame adjustment for American Flame valve.; Correct DVR28 flame. Center flame should be ap-
20012301 19 Vermont Castings DVR28 Direct Vent Gas Fireplace Flame & Temperature Adjustment To adjust Hi/Lo setting, push either the high or low con-trol button on remote control transmitter. Flame Characteristics It is important to periodically perform a visual check of the pilot and the burner...
Page 20 - Lighting & Operating Instructions; For Your Safety, Read the Following Warnings; result, causing property damage, personal injury and loss of life.; Lighting Instructions; DO NOT; Valve in the; “ON”; position
20 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace Lighting & Operating Instructions For Fireplaces equipped with AF4000 Gas Valve A. This fireplace is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand. B. BEFORE OPERATING , sme...
Page 21 - Troubleshooting
20012301 21 Vermont Castings DVR28 Direct Vent Gas Fireplace Troubleshooting AF4000 Valve If erratic system behavior is observed that cannot be resolved by the methods outlined below, ensure that there is not a transmitter with batteries installed that may be interfering. If a transmitter is packed ...
Page 22 - Troubleshooting AF4000 Valve; Pilot will not light/stay lit; A proper ground is essential to spark; Figure 39: Wall Transmitter Face
22 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace Troubleshooting AF4000 Valve (continued) Pilot will not light/stay lit • Verify the gas supply is turned on. • Verify the receiver is receiving the signal from the transmitter by listening for a beep from the receiver when ON is pressed on...
Page 23 - Verify the gas supply is turned on.; Main flame will not light; Figure 40: Battery Pack - Battery Compartment
20012301 23 Vermont Castings DVR28 Direct Vent Gas Fireplace • Ensure the CONTINUOUS PILOT switch on the control module (Fig. 36) is set to OFF. • Verify the gas supply is turned on. • Ensure the pilot flame will ignite. If not, see pilot flame troubleshooting above. • Make sure the green and white le...
Page 24 - Burner and Burner Compartment; Cleaning the Standing; If repair is necessary, it should be per-; Maintenance
24 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the burner compartment should be vacuumed and wiped out. Cleaning the Standing Pilot Control System The burner and co...
Page 26 - Optional Accessories; Curve Face Kit; Color; Rustic Bronze
26 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace Optional Accessories Curve Face Kit Model # Color ICVCTK04 Rustic Bronze ICVCTK05 Charcoal Screen Door Kit Model # ICVCSTK
Page 27 - IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty,; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
20012301 27 Vermont Castings DVR28 Direct Vent Gas Fireplace BASIC WARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the...
Page 28 - CFM Corporation; Efficiency Ratings; Model
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www.cfmcorp.com CFM Corporation Efficiency Ratings Model EnerGuide Ratings Steady State (%) D.O.E. Fireplace Efficiency (%) Fan-OFF Fan-ON (AFUE%) DVR28IN 67.6 85 n/a 64.3