Vermont Casting 3225 - Manual

Vermont Casting 3225

Vermont Casting 3225 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
Page: / 44

Table of Contents:

  • Page 2 – Radiance Direct Vent/Natural Vent Gas Heater; Table Of Contents
  • Page 3 – Radiance Direct Vent /Natural Vent Gas Heater; Completion of sale, nor for purpose of resale,; Installation & Operating Instructions
  • Page 4 – Radiance Direct Vent/Natural Vent Stove Dimensions; Attention
  • Page 5 – Installation Requirements; Locating The Stove; Possible stove locations.; Direct Vent System Only; Stardance; Clearance Requirements; Minimum Clearances to Combustible Materials
  • Page 6 – Parallel installation, minimum back and side clear-; Corner installation, minimum corner clearances and; Minimum wall centerline.; Sidewall Clearance; Direct Vent Only
  • Page 7 – Radiance Direct Vent/Natural Vent; Input; Gas Inlet and Manifold Pressures; ment, alteration, service or maintenance; Horizontal Termination -
  • Page 8 – Vent Termination Clearances; NOTE: The restrictor; Vertical vent termination window.; IMPORTANT
  • Page 10 – General Venting Information - Termination Location; Canadian Installations
  • Page 11 – Termination clearances.; Venting Runs; (Measured from top of the unit before any elbow); NOTE: When venting staight vertical, without any; Venting Requirements - Natural Vent Only; Vent termination window - Natural Vent ONLY.; Outside Corner; Termination Clearances; with no side wall; of Caps
  • Page 12 – Venting Requirements and Options -; Approved Vent System Components; Simpson DuraVent Components; Direct vent pipe may be used on the Natural
  • Page 13 – Slide stove back just far enough to access rear leg; Assembly Procedures; Failure to position the parts in accor-; WARNING; Tools Required; Radiance; Carefully tip stove onto back legs. Leave pallet under
  • Page 14 – JUV; Attach the fan rheostat.; Install the Optional Fan; Remove rear shroud.; Fan kit components.; Steps 3 and 4 do not apply when the RF valve; Attach blower assembly and snapstat.; Attach the control knob to the rheostat shaft.
  • Page 15 – Venting System Assembly - Direct Vent; For Canadian installations:; Install the Vent Adapter Pipe; Install the restrictor plate only if required for the vent-; Attach the Inner Vent Assembly to the stove.; attach inner pipe; Connect the inner starter with the next section of; attach inner assy
  • Page 16 – Side Wall Termination Assembly; Discard the inner starter pipe; install outer adpater; dura vent; Simpson DuraVent - install inner adpater pipe.; Vent Opening; Combustible Wall; Locate vent opening.; CFM System
  • Page 17 – For DuraVent pipe only:; Zero Clearance Sleeve; Assemble the wall sleeve and firestop.; measure vertical vent; Determine the vertical pipe length.; measure thru wall; Measure the horizontal length.; install pipe thru wall; Install the horizontal pipe and wall plate parts.
  • Page 18 – Vent Assembly; install snorkel; Snorkel kit installation.; Vent Termination Below Grade; If the; snorkel detail; Use extension brackets to mount snorkel against; install wall terminal; Install the vent terminal.
  • Page 19 – vent thru roof; Roof support and flashing.; Venting System Assembly - Natural Vent; Install firestops and attic insulation shield.
  • Page 20 – Install Log Set; Remove the stove front.; Release the latches to remvoe the glass frame.; Install the Vent Pipe; attach draft hood
  • Page 21 – Install the left and right rear logs and the right log.; Install the right log by engaging hole on the bottom; Connect the Gas Supply Line; Gas connection should be made in ac-; Radiance logs; Completed log installation.; Top View; Lava rock placement.; Radiance logs
  • Page 22 – Use only a thermostat rated for 500 - 750 millivolts.; Install ON/OFF Switch; PILOT; attach switch; Attach switch wires to valve.; Install the Mesh and Grille; THIS APPLIANCE SHOULD BE CON-; In order to connect Natural Gas,; CAUTION; attach switch assy; Attach switch assembly to rear shroud.; Thermostat
  • Page 23 – Operation; Your First Fire; handle holder; When not in use, store handle in the handle holder.; Pilot Assembly location.; To open the front doors, turn handle counterclockwise.; Flame & Temperature Adjustment; Flame adjustment knob for Honeywell valve.; Flame Characteristics; Correct pilot and burner flame patterns.; Pilot flame; SIT Pilot
  • Page 24 – FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; To Turn Off Gas To Heater; Lighting and Operating Instructions; Lighting Instructions; Lighting instructions
  • Page 25 – Troubleshooting / Honeywell #8420 Gas Control System; SYMPTOM
  • Page 26 – comfort valve; Transmitter diagram.; Honeywell; Comfort control valve.
  • Page 27 – If an Error Code 3 is observed while performing the; Blower; Comfort Valve wiring diagram.
  • Page 28 – Local Path
  • Page 29 – above; Auto Path; below
  • Page 30 – Adjust air shutter according to Table 2.; Conversion Precautions; Burner Orifice Conversion; Fuel Conversion Instructions; attach gas line; Attach the gas line to the left side of the valve.; Jefferson; Remove rear log bracket and left and right log bracket; Conversion Procedure
  • Page 31 – Remove mounting screws, pressure regulator tower; SIT; Pilot Orifice Conversion; gas conversion; Remove pilot hood.; Gas Conversion; Remove pilot orifice.
  • Page 32 – Remove pilot hood. (Your pilot may have a different; Depress and turn center plunger.; injector orifice; All Models
  • Page 33 – Model; RDVOD, RDVOD with; Table 2. Air Shutter Adjustment; Conversion to Natural Gas; Table 1. Injector Orifice Size Matrix
  • Page 34 – Maintenance; painted surfaces; Remove the Stove Front.
  • Page 35 – Gasket Replacement; Determine the correct length of gasket by laying it; Inspect the Vent System Annually; glass gasket detail; Wrap the gasket material around the outside edge of; Correct flame pattern.; Release the latches to remove the glass frame.
  • Page 36 – BLK; rdv connections diag.; Schematic Diagram; Wiring Diagrams; On/off switch and optional thermostat circuit.; Used on
  • Page 37 – RDVOD; Manifold Assembly
  • Page 39 – Fuel Conversion Kits
  • Page 40 – Optional Accessories; Fan Kits
  • Page 43 – BASIC WARRANTY; COMPONENT WARRANTY; IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty,; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
  • Page 44 – Efficiency Ratings; RDVODRN; CFM Corporation
Loading the manual

INSTALLER / CONSUMER

SAFETY INFORMATION

20004188 1/07 Rev. 18

PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.

WARNING!

IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY

Installation and service must be
performed by a qualified installer,
service agency or the gas suppler.

WHAT TO DO IF

YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch; do
not use any phone in your building.

Immediately call your gas supplier
from your neighbor’s phone. Follow
the gas supplier’s instructions.

If you cannot reach your gas supplier,
call the fire department.

DO NOT STORE OR USE
GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS
OR ANY OTHER APPLIANCE.

This appliance may be installed in an
after market permanently located
manufactured (mobile) home where not
prohibited by local codes.

This appliance is only for use with the
type of gas indicated on the rating plate.

This appliance is not convertible for use
with other gases unless a certified kit is
used.

Radiance
Direct Vent/Natural Vent
Gas Heater

Model RDVOD: 3225 thru 3232,
3350 thru 3354, 3360 thru 3369,
3390 thru 3399

Homeowner’s Installation

and Operating Manual

C E R T I F I E D

DESIGN

C ERTIFIE D

4188

Radiance

cover

4/01

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Radiance Direct Vent/Natural Vent Gas Heater; Table Of Contents

2 2 Radiance Direct Vent/Natural Vent Gas Heater 20004188 PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Vermont Castings stove. IMPORTANT: Read all instructions and warnings carefully before starting installation...

Page 3 - Radiance Direct Vent /Natural Vent Gas Heater; Completion of sale, nor for purpose of resale,; Installation & Operating Instructions

3 Radiance Direct Vent /Natural Vent Gas Heater 20004188 The Radiance Direct Vent/Natural Vent Room Heater, Model Nos. 3350 thru 3354, 3360 thru 3369 and 3390 thru 3399, is a vented gas appliance listed to the ANSI standard Z21.88b-2002 and CSA-2.33b-2002 for Vented Room Heaters, and CSA 2.17-M91, G...

Page 4 - Radiance Direct Vent/Natural Vent Stove Dimensions; Attention

4 4 Radiance Direct Vent/Natural Vent Gas Heater 20004188 29 ��� " (7.6cm) 31" (7.9cm) 7" Outer Dia. (1.8cm) � ����������� � 4 ��� " (1.2cm) 14 ��� " (3.7cm) ST126 RDV40 dimensions 10/99 � � � � � � � � 28" (711mm) 5" (127mm) 9 ��� " (241mm) 18 ��� " (464mm) Suppl...

Other Vermont Casting Models

All Vermont Casting Other