Page 2 - Table of Contents
2 NVC Series B-Vent 20000194 Table of Contents Thank you and Congratulations on your purchase of a CFM Corporation fireplace. PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORTANT: Read all instructions and warnings carefully before starting installation. Fail...
Page 3 - Installation & Operating Instructions; Natural Gas and Propane In-; Proposition 65 Warning:
3 NVC Series B-Vent 20000194 Installation & Operating Instructions This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Natural Gas and Propane In- stallation Code. If the unit is being installed in a mobile home, the ...
Page 4 - INSET A; Fireplace Dimensions; Fireplace specifications and framing dimensions.; Framing Dimensions; Appliance Dimensions
4 NVC Series B-Vent 20000194 A D N M N A B S G H J Gas Line Access - 2" Dia. Gas Line Access 2" Dia. Finished Wall Thickness 6" Flue Rough Opening Height Rough Opening Width Rough Opening Depth C Electrical Cable Knock-out - 1" Dia. E L F K P Q R Electrical Box Knock-out - 2" Dia...
Page 5 - Clearance to Combustibles; Appliances; Mantels; Mantel; Combustible mantel leg minimum installation.; Hearth; Cold climate installation recommendation: When
5 NVC Series B-Vent 20000194 Clearance to Combustibles Appliances Top .......................................................... 0” (0 mm) Bottom ..................................................... 0” (0 mm) Side ......................................................... 0” (0 mm) Back ...............
Page 6 - Vented Gas Fireplace Heaters; High Elevations; Natural; Gas Inlet & Manifold Pressures; Model
6 NVC Series B-Vent 20000194 Gas Specifications 1. Choose the unit location. 2. Place the unit into position and secure it to the floor with 1 ¹⁄₂ ” (38mm) screws, or nails. The holes to secure the unit to floor are located just behind the access door grille on the left and right side of the unit. 3. F...
Page 7 - Gas Line Installation; Always provide a union; so that gas line can; Remote Switch Installation; Thread wire through the electrical knockout located; Alternate Switch Location; Supply Line; Typical gas supply installation.; Installing remote switch bracket.
7 NVC Series B-Vent 20000194 Gas Line Installation When purging gas line the fornt glass must be removed. Purging gas lines must com-ply with ANSI Z223.1/NFPA 54 in USA and CSA B149.1 in Canada. The gas pipeline can be brought in through the right or left side of the appliance, as well as the bottom...
Page 8 - Outside; Electrical Box; Inside; Retaining Screw; Install the Venting System,
8 NVC Series B-Vent 20000194 The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the ab-sence of local codes, with the current CSA C22.1 Canadian Electrical Code For USA installations follow the local codes and the national electrical code ...
Page 9 - Ceiling Installation; FIRESTOP; Attic Installation; Table 1; Venting configurations.; Venting Runs; Ve; (Measured from floor of unit tocenter of hor
9 NVC Series B-Vent 20000194 Fig. 9 Firestop/draftstop positions. Ceiling Installation FP384 FIRESTOP 11/21/96 adapted from IGF53 Attic Installation Firestop position when area above ceiling is an attic. Firestop position when area above ceiling is NOT an attic. (Firestop/draftstop appearances may v...
Page 10 - Operating Instructions; Glass Information; Window frame assembly removal.; Glass Cleaning; Louvre install and removal.; Window Frame Assembly Removal
10 NVC Series B-Vent 20000194 Operating Instructions Only glass approved by CFM Corporation should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass. • Do not operate appliance with glass fr...
Page 11 - Lava Rock; Flame adjustment knob for Honeywell valve.; Flame adjustment knob for SIT valve.; Flame Characteristics; NVB; ELECTRONIC; Proper pilot flame height.; Electronic
11 NVC Series B-Vent 20000194 6. Place the top logs onto the locator notches. Ensure that the logs a re secure. (Fig. 12) 7. Place ember material. See "Ember Material Place- ment" section. NVC36 NVC39 NVC43 Front Left Log BB6 BC5 BD6 Front Right Log BB7 BC6 BD7 Rear Log BE5 BC7 BD8 Top Left ...
Page 12 - Test Chimney Draw; exhaust fans in the kitchen and bathroom.; Approximate flame heights for each model.; Inspecting the Venting System; draft test location; Test for Draft at This Location; Draft test location.; First Firing
12 NVC Series B-Vent 20000194 Test Chimney Draw A "Chimney Draw" test must be made before the instal-lation is complete.1. Close all doors and windows in the home and start exhaust fans in the kitchen and bathroom. 2. Light unit and operate for 5 minutes.3. Hold an ignited match, cigarette, ...
Page 13 - FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; To Turn Off Gas To Heater; Lighting and Operating Instructions; Lighting Instructions; Euro SIT
13 NVC Series B-Vent 20000194 3. Open control access panel.4. Push in gas control knob slightly and turn clock- wise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace.3. For MN/MP/TN/TP applianc...
Page 14 - Remove the front louvre assembly.; CAUTION: The components may still be hot.; Light the fireplace and check for downdrafts.; DO NOT ATTEMPT TO RESET THE; Turn off the fireplace and contact; Electrical Connection; Vent safety switch; Vent Safety Switch.; Vent Safety Switch
14 NVC Series B-Vent 20000194 Vent Safety Switch This fireplace incorporates the use of a Vent Safety Shut-off Switch. The sensor and wiring are factory installed and should not be removed or altered during installation. In the event of total flue blockage the system will detect the increased heat bui...
Page 15 - Troubleshooting; START; CHECK; Honeywell Electronic Ignition
15 NVC Series B-Vent 20000194 Troubleshooting FP649 Turn gas supply off Turn ON/OFF Switch to call for heat. NO NO NO NO NO NO NO Spark across Ignitor Sensor gap Power to module (24V nominal) YES YES YES YES YES YES YES Turn gas on Pilot burner lights? Spark stops when pilot is lit? Main Burner ligh...
Page 16 - Remove glass door before service work
16 NVC Series B-Vent 20000194 Remove glass door before service work Honeywell VS8421 START CHECK Gas Supply On Pilot Lights With Piezo Ignitor • Lockout Has Engaged. Wait 60 Seconds And Try Again. • For Spark At Electrode While Depressing Piezo 1/8" Gap To Pilot Hood Needed. • All Wiring Connect...
Page 17 - Nova SIT 820 Standing Pilot
17 NVC Series B-Vent 20000194 Troubleshooting FP396 Gas Supply On Supply Line Hooked Up Shutoff Valve Open NO NO NO NO Lockout Has Engaged. Wait 60 Seconds and Try Again. Piezo Nut Tight for Good Ground. For Spark at Electrode While Depressing Piezo (Red Button) - 1/8" Gap to Pilot Hood Needed. ...
Page 18 - If repair is necessary, it should be per-; Nova SIT Pilot; Correct pilot flame appearance.; Maintenance; Burner and Burner Compartment
18 NVC Series B-Vent 20000194 Cleaning the Standing Pilot Control System The burner and control system consists of • burner tube • gas orifice • pilot assembly • thermopile • millivolt gas valve Most of these components may require only an oc-casional checkup and cleaning and some may require adjustm...
Page 19 - Ref. Description; Log Set Complete
19 NVC Series B-Vent 20000194 FP772A Replacement Parts nvc 8/25/98 31 28 29 26 6a/b 4a/b 5 36 35 34 1a 1b 1c 1d 1e NVC43 Logs 1 27 37 2 3 1a 1b NVC36 1d 1e 1c 1e 1c 1a 1b 1d NVC39 1 18 25 17a/b 22 19 �� � � � � � �� ��� ��� ���� �� ����� �� �� �� �� �� � ��� ���� ��� ��� �� � � � ���� ���������� � �...
Page 21 - Optional Accessories; Fan Kits; FK12 Fan Assembly; WIRING DIAGRAM
21 NVC Series B-Vent 20000194 Optional Accessories Fan Kits FK12 Fan Assembly 1. Open louvre assembly bottom.2. Install FK12 fan in back of unit between hearth sup- ports. 3. Secure fan on velcro strips.4. Power to the fan can be supplied by plugging the supply lead into a conveniently located wall ...
Page 22 - Remote Controls; Ceramic Refractory Panels; Unit; Install ceramic refractory panels.; Arched Door Front; Arched door front
22 NVC Series B-Vent 20000194 Remote Controls Optional remote control units are available to control different functions of the appliance. Model Function(s) Controlled MRC1 ON/OFF MRC2 ON/OFF and Temperature MRC3 ON/OFF and Temperature control with a digital and a programmable 24 hour clock IMT Wall...
Page 23 - Arched door front in place.; Decorative Frame Trims
23 NVC Series B-Vent 20000194 FP1195 Arched door front 2/27/02 djt FP1196 Fig. 28 Arched door front in place. EB-1 Electrical Box Standard on electronically controlled models, the EB-1 is also available for other fireplaces. Installation should be completed by a qualified service person. Decorative Fr...
Page 27 - IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty,; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
27 NVC Series B-Vent 20000194 BASIC WARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to th...
Page 28 - CFM Corporation; Efficiency Ratings
2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.com CFM Corporation Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) NVC36RN 29.4 NVC36RP 29.4 NVC36RFN 29.4 NVC36RFP 29.4 NVC36EN 28.5 NVC36EP 28.5 NVC39RN 26.4 NVC39RP 26.4 NVC39RFN 26.4 NVC39R...