Vermont Casting H33BDVRRNP - Manual

Vermont Casting H33BDVRRNP

Vermont Casting H33BDVRRNP – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – Pyromaster; Venting Installation Instructions; Table of Contents
  • Page 3 – PLEASE REVIEW THE FOLLOWING CAREFULLY; Installation & Operating Instructions; Locating Your Fireplace
  • Page 4 – Fireplace Dimensions; Fig. 2 Fireplace specifications and framing dimensions.; Framing Dimensions
  • Page 5 – Rear Vent Applications:; Hearth; Fig. 3a Combustible mantel minimum installation.
  • Page 6 – Certified To; Vented Gas Fireplace Heaters
  • Page 7 – Installation; Thread the wiring through the holes on the end; Alternate Switch Location
  • Page 8 – General Venting Information - Termination Location; Canadian Installations
  • Page 9 – Outside Corner; Termination Clearances; Recessed Location; Crimped End Pipes; Canadian Installations:; General Information on Assembling DV Components; Fig. 9 Apply a bead of high temperature sealant.
  • Page 10 – Twist Lock Pipes; How to Use the Vent Graph; Rear Wall Vent Applications
  • Page 11 – Combustible Walls: Cut a 10; Rear Wall Installations
  • Page 12 – Fig. 16 Side view of final unit location.; Vertical Sidewall Applications; The maximum number of 90; Fig. 18 Maximum horizontal vent run before termination.
  • Page 13 – Vertical Sidewall Installations; elbow is; Vent Opening for Combustible Wall; Total angular variation = 270
  • Page 14 – Fig. 22 Zero clearance sleeve and firestop.
  • Page 15 – Below Grade Installations
  • Page 17 – Typical Roof; Install appropriate pipe sections until the venting is; Fig. 34 Minimum termination to roof clearance.
  • Page 18 – Twist Lock Venting Components
  • Page 19 – Crimped End Venting Components
  • Page 20 – If the unit has been operating allow time for the; Operating Instructions
  • Page 21 – Flame Characteristics; Location; Front Right; Refer to Figure 37; Scatter the ember material over the front area of the; Scatter the lava rock material around the firebox base.; LO
  • Page 22 – FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; To Turn Off Gas To Heater; Lighting And Operating Instructions; Lighting Instructions; Euro SIT
  • Page 23 – Troubleshooting – Honeywell VS8421; Remove Glass Doors Before Service Work
  • Page 24 – LP Conversion Kit Components
  • Page 25 – Maintenance; Burner and Burner Compartment
  • Page 26 – Description; Burner Housing Assembly
  • Page 28 – FK24 Fan Assembly; Optional Accessories Available; Fan Kits
  • Page 29 – Wiring Instructions; Ceramic Refractory Kits; Inside
  • Page 30 – Decorative Bay Windows; Fig. 45 Ceramic refractory installation.
  • Page 31 – Model; Remote Controls; Let the fireplace cool down if it has been operating.; Trim Kit
  • Page 32 – LIMITED WARRANTY & EXTENDED LIFE TIME PROTECTION; For Pyromaster; CFM Harris Systems
Loading the manual

10004798 11/02 Rev. 0

INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER

Builder Rear Vent
Direct Vent

DO NOT STORE
OR USE GASOLINE OR
OTHER FLAMMABLE
VAPORS AND LIQUIDS IN
THE VICINITY OF THIS OR
ANY OTHER APPLIANCE.

WHAT TO DO IF YOU SMELL
GAS:

Do not try to light any appliance.

Do not touch any electric switch;
do not use any phone in your
building.

Extinguish all flames.

I m m e d i a t e l y c a l l y o u r g a s
supplier from your neighbor's
phone. Follow the gas suppliers
instructions.

If you cannot reach your gas
supplier call the fire department.

Open windows/extinguish all
flames.

WARNING!

IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING
PROPERTY DAMAGE, PER-
SONAL INJURY OR LOSS OF
LIFE.

FOR YOUR SAFETY
Installation and service must
be performed by a qualified
installer, service agency or the
gas supplier.

PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE

INSTALLER/CONSUMER

SAFETY INFORMATION

Model: H33BDVRRN/P

Homeowner's Installation and

Operating Manual

DESIGN

C E R

T I F I E D

C E R T I F I E D

3501 West Howard • Skokie, IL 60076 • 847-676-3556

www.cfmharris.com

CFM Harris Systems

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Pyromaster; Venting Installation Instructions; Table of Contents

2 Pyromaster © H33BDVRRN/P 10004798 Installation & Operating Instructions ........................................................................................... 3 Locating Your Fireplace .................................................................................................... 3Fi...

Page 3 - PLEASE REVIEW THE FOLLOWING CAREFULLY; Installation & Operating Instructions; Locating Your Fireplace

3 Pyromaster © H33BDVRRN/P 10004798 A) Flat on wall B) Cross corner C) **Island D) *Room divider E) *Flat on wall corner F) Chase installation Y) 6" minimum Note (Fig. 1):** Island (C) and Room Divider (D) installation is possible as longas the horizontal portion of the vent system (X) does not ...

Page 4 - Fireplace Dimensions; Fig. 2 Fireplace specifications and framing dimensions.; Framing Dimensions

4 Pyromaster © H33BDVRRN/P 10004798 Fireplace Dimensions Fig. 2 Fireplace specifications and framing dimensions. F Q - Rough Opening Width RoughOpeningHeight RoughOpeningDepth M M O N P E I H J C A D R B K L G 4758 Ref. H33BDVRRN/P A 33” (838mm) B 28 ⁷⁄₈ ” (733mm) C 16 ³⁄₈ ” (416mm) D 31” (787mm) E ...

Other Vermont Casting Models

All Vermont Casting Other