Vermont Casting SDV30 - Manual

Vermont Casting SDV30

Vermont Casting SDV30 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
Page: / 44

Table of Contents:

  • Page 2 – Stardance Direct Vent/Natural Vent Gas Heater; Table of Contents
  • Page 3 – General Information; Fuels used in gas, woodburning or
  • Page 4 – Stardance Direct Vent / Natural Vent Dimensions; Attention
  • Page 5 – Clearance Requirements; Installation Requirements; Locating the Stove; We do not recommend the use of wallpaper; Possible stove locations.; • Always maintain required clearances
  • Page 6 – Direct Vent Only; Stardance
  • Page 7 – Gas Specifications; Input Input; Gas Inlet and Manifold Pressures; Stardance Direct Vent / Natural Vent; High Elevations
  • Page 8 – Vertical Termination - Direct Vent ONLY; bow. No more than six elbows may be used.; Vertical vent termination window.; Unacceptable Venting; Vent Termination Clearances
  • Page 9 – Location of Vent Termination
  • Page 10 – General Venting Information - Termination Location; Canadian Installations
  • Page 11 – Termination clearances.; Venting Requirements - Natural Vent Only; = Acceptable venting configuration; Vent termination window - Natural Vent ONLY.; Outside Corner; Termination Clearances; with no side wall; of Caps
  • Page 12 – Venting Requirements and Options -; Approved Vent System Components; CFM Vent Components
  • Page 13 – Install the Optional Fan; WARNING; The rheostat control switch attaches to the left side; Fan kit components.; Remove the rear skirt insert panel at the bottom of; install fan kit; Remove rear skirt insert.; attach fan; Attach the fan assembly and the snapstat.; JUV; Attach the fan rheostat.
  • Page 14 – Venting System Assemlby - Direct Vent; For Canadian installations:; Install the Vent Adapter Pipe; install restrictor plate; Install the restrictor plate only if required for the vent-; Dry fit the Inner Pipe assembly to the stove for; Connect the inner starter with the next section of in-; Attach inner assembly to flue collar.; install outer adpater
  • Page 15 – Discard the inner starter pipe; dura vent; Side Wall Termination Assembly; Vent Opening; CFM System; Locate vent opening.; Zero Clearance Sleeve; Assemble the wall sleeve and firestop.
  • Page 16 – For DuraVent pipe only:; Determine the vertical pipe length.; measure thru wall; Measure the horizontal length.; install pipe thru wall; Install the horizontal pipe and wall plate parts.; install wall terminal; Install the vent terminal.
  • Page 17 – Vent Termination Below Grade; If the; install snorkel; Snorkel kit installation.; snorkel detail; Use extension brackets to mount snorkel against; Vent Assembly
  • Page 18 – vent thru ceiling; Install firestops and attic insulation shield.; vent thru roof; Roof support and flashing.; Venting System Assembly - Natural Vent; Decorative; Decorative 7” pipe may be fitted around the B-vent
  • Page 19 – Install the Vent Pipe; Completed log installation.; Connect the Gas Supply Line; CAUTION
  • Page 20 – Burner Information; In order to connect Natural Gas,; Air Shutter Adjustment; Model; Air Shutter Adjustment Instructions; Remove stove front.; Jefferson; Remove rear log bracket and left and right log
  • Page 21 – jefferson; Air shutter adjusted.; Be sure to maintain 90° angle at left burner leg.; Complete the Assembly; attach switch assy; Attach switch assembly to rear shroud.; Attach switch wires to valve.
  • Page 22 – Use only a thermostat rated for 500 millivolts.; Install the wall thermostat in the desired location and; Install the Front Plate; Install the front plate.; This completes assembly of the Stardance stove.
  • Page 23 – Operation; To open the front doors, turn handle clockwise.; handle holder; When not in use, store handle in the handle holder.; Your First Fire; Pilot assembly location.; Flame & Temperature Adjustment; LO; Flame adjustment knob for Honeywell valve.; Flame Characteristics; Pilot flame; Correct pilot and burner flame patterns.
  • Page 24 – FOR YOUR SAFETY READ BEFORE LIGHTING; Follow the gas supplier’s instructions.; To Turn Off Gas To Heater; Lighting and Operating Instructions; Lighting Instructions; Euro SIT; Lighting instructions
  • Page 25 – Troubleshooting / Honeywell #8420 Gas Control System; SYMPTOM
  • Page 26 – Comfort control valve.; Transmitter diagram.
  • Page 27 – LED Count; Pilot; Valve; Comfort valve wiring diagram.
  • Page 28 – Local Path
  • Page 29 – Auto Path; If the setting is; above; If the settings is; below
  • Page 30 – Fuel Conversion Instructions; attach gas line; Attach the gas line to the left side of the valve.; Conversion Precautions; Remove the rear log bracket and left and right log
  • Page 31 – Remove mounting screws, pressure regulator tower; SIT; Pilot Orifice Conversion; gas conversion; Pilot type 2; Gas Conversion; Gas Conversion; Remove pilot orifice.
  • Page 32 – Depress and turn center plunger.; injector orifice; Remove and replace injector orifices.; Table 2. Injector Orifice Size Matrix
  • Page 33 – Maintenance; Annual System Inspection; ERATE THE HEATER WITH DAMAGED LOGS.; Care of Cast Iron; Remove the stove front.
  • Page 34 – Release the latches to release the glass frame.; Gasket Replacement; Determine the correct length of gasket by laying it; glass gasket detail; Wrap the gasket material around the outside iedge of; Inspect the Vent System Annually; Correct flame pattern.; Stove Disassembly
  • Page 35 – Wiring Diagrams; Thermostat; On/Off switch and optional thermostat circuit.; Draft hood adapter wiring.; AN; BLK; FK26 wiring diagram; Schematic Diagram; Stardance fan circuit.
  • Page 39 – Optional Accessories; Fan Kits
  • Page 42 – BASIC WARRANTY; IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty,; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
  • Page 43 – GARANTIE DE BASE; SI UN SERVICE SOUS GARANTIE EST REQUIS...; GARANTIE À VIE LIMITÉE; PRODUIT COUVERT PAR LA PRÉSENTE GARANTIE
  • Page 44 – Efficiency Ratings; CFM Corporation
Loading the manual

INSTALLER / CONSUMER

SAFETY INFORMATION

PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.

WARNING!

IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY

Installation and service must be
performed by a qualified installer, service
agency or the gas suppler.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier from

your neighbor’s phone. Follow the gas
supplier’s instructions.

• If you cannot reach your gas supplier,

call the fire department.

DO NOT STORE OR USE GASO-
LINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER
APPLIANCE.

This appliance may be installed in an after
market permanently located manufactured
(mobile) home where not prohibited by
local codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases unless a certified kit is
used.

Stardance
Direct Vent/Natural Vent
Gas Heater

Model SDV30: 3900-3916, 3940-
3956

7065

SDV

fully assembled cover

1/6/04

Homeowner’s Installation

and Operating Manual

C E R T I F I E D

DESIGN

C ERTIFIE D

20007065 1/07 Rev. 13

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Stardance Direct Vent/Natural Vent Gas Heater; Table of Contents

2 Stardance Direct Vent/Natural Vent Gas Heater 20007065 PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Vermont Castings stove. IMPORTANT: Read all instructions and warnings carefully before starting installation....

Page 3 - General Information; Fuels used in gas, woodburning or

3 Stardance Direct Vent/Natural Vent Gas Heater 20007065 General Information The Stardance Direct Vent/Natural Vent Room Heater, Model Nos. 3900-3916, 3940-3956 is a vented gas appliance listed to the ANSI standard Z21.88b-2002 and CSA-2.33b-2002 for Vented Room Heaters, and CSA 2.17-M91, Gas-Fired ...

Page 4 - Stardance Direct Vent / Natural Vent Dimensions; Attention

4 Stardance Direct Vent/Natural Vent Gas Heater 20007065 Stardance Direct Vent / Natural Vent Dimensions 9" (229 mm) CL Valve Inlet 26 ��� " (680 mm) 25" (635 mm) 14 ��� " (355 mm) 3" (76 mm) CL 7065Stardance fully assembleddimensions1/6/04 djt Valve Inlet Attention The Stardance...

Other Vermont Casting Models

All Vermont Casting Other