Page 2 - SHR Series Woodburning Fireplace; Safety Information; Description; before; beginning installation.; Any such action may possibly cause a fire hazard.; installing the fireplace.; Proposition 65 Warning:; Drafts; Standard for Factory Built Fireplaces; Table of Contents
2 SHR Series Woodburning Fireplace 20001384 Safety Information PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE.IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void th...
Page 3 - SHR Series Woodburning Fireplaces; SHR42A Series Woodburning Fireplace; SHR36 Series Woodburning Fireplace
3 SHR Series Woodburning Fireplaces 20001384 Rough Opening Height 42" (1067mm) 52 ��� " (1327mm) 48 ��� " (1222mm) ��� " ��� " 28 ��� " (724mm) ����� " (189mm) 13 ��� " Dia. (340mm) Rough Opening Width 53 ��� " Rough Opening Depth 65 ��� " (1654mm) 65 ��� "...
Page 4 - SHR48 Series Woodburning Fireplace; SHR52 Series Woodburning Fireplace
4 SHR Series Woodburning Fireplace 20001384 ����� " (724mm) 7 ��� " (197mm) 48" (1219mm) 58 ��� " (1480mm) 48 ��� " (1232mm) ��� " ��� " ����� " (189mm) 13 ��� " Dia. (340mm) Rough Opening Width 59 ��� " Rough Opening Height Rough Opening Depth 66 ��� " (1...
Page 5 - Chase Installation; hearth dimensions; Front Width
5 SHR Series Woodburning Fireplaces 20001384 FP554A SH Series 1/28/99 djt Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation. FP554A Fig. 5 Fireplace and chase parts identification. (SHR48 shown) Termination Cap Storm Collar Pan Flashing Ba...
Page 6 - Chimney Requirements - Offset Installations; Illustration Key; Offset
6 SHR Series Woodburning Fireplace 20001384 Chimney Requirements - Offset Installations 0 0 0 0 0 3" 11" 1 0 0 0 0 8 ¹⁄₄ " 20" 0 1 0 0 0 11 ¹⁄₄ " 25 ¹⁄₄ " 2 0 0 0 0 13 ¹⁄₂ " 29 ¹⁄₄ " 1 1 0 0 0 16 ¹⁄₂ " 34 ¹⁄₄ " 0 0 1 0 0 20 ¹⁄₄ " 40 ³⁄₄ " 2 1 0 0 0 21 ...
Page 7 - Planning Information; The Ten Foot Rule; must; Planning the Chimney Run; Never
7 SHR Series Woodburning Fireplaces 20001384 Planning Information The Ten Foot Rule Major U.S. building codes specify a minimum chimney height above the roof top. The “Ten Foot Rule” is a fire safety rule and not a draft rule. To ensure proper draft, it is recommended that you always meet or exceed t...
Page 8 - Installation; Chimney Supports; must not; highly recommended
8 SHR Series Woodburning Fireplace 20001384 Installation Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30 feet above the hearth. Chimney supports are required if the vertical height exceeds 30 feet with 11CF chimneys. Locate chimney supports ...
Page 9 - Framing; Framing should be positioned to accommodate; Firebrick Installation; The screens and screen rod smoke baffle as-; Firebrick; hearthbrick
9 SHR Series Woodburning Fireplaces 20001384 Framing Framing can be constructed before or after the fireplace is set in place, however, most installers build the frame before setting the fireplace.Frame fireplace with 2 x 4 lumber or heavier materials. Refer to framing dimensions in Figures 1 - 4 for b...
Page 10 - Angle of Chimney at Ceiling; CHIMNEY HOLE SIZE; REPORT TO YOUR DEALER ANY PARTS; only; to the 11CF system, chimney components may
10 SHR Series Woodburning Fireplace 20001384 FP556SHR Fig. 13 Locate centerline of chimney with plumb line. FP556SHR SHR LOCATE CENTER LINE 5/11/99 djt Chimney Centerline Actual Centerpoint Plumb Line Plumb Bob Imaginary Centerpoint 11 ¹⁄₈ " (283 mm) FP 548b SHR 5/11/99 djt Angle of Chimney at C...
Page 11 - inside dimension; Securing the Fireplace; Installing Outside Air Kit; MUST
11 SHR Series Woodburning Fireplaces 20001384 The inside dimension of the frame must be the same as the hole size selected from Figure 11 in order to provide the required 2 inches of air space between the outside diameter of the chimney and the edges of the framed ceiling hole. Positioning, Safety S...
Page 12 - Installing the Chimney System; Make sure the; ELBOW STRAP; Installing the Firestop Spacer; A firestop spacer is; Proper Firestop Spacer Installation; is not; an attic, position the; an attic, position the
12 SHR Series Woodburning Fireplace 20001384 Installing the Chimney System Start by attaching the first chimney section to the collar on top of the fireplace. Install the pipe as pictured in Figure 19. When you get a good lock, you will hear the pipe clearly snap together. Once sections are snap-locke...
Page 13 - Attic Installation; Chimney supports are generally used in long; use an approved; horizontal; Ten Foot Rule
13 SHR Series Woodburning Fireplaces 20001384 Attic Installation Ceiling Installation Fig. 21 Installing firestop spacer. FP285 IWF285 mbuf 5/25/96 Nails (4) Firestop Spacer Joist Joist Firestop Spacer Nails (4) Flange Down Into Hole Flange Up Into Hole Continue Installing Pipe to Complete Run Contin...
Page 14 - Installing Chimney in a Chase; Finishing; Do not; SHR air spaces; Air Space Clearances; Front View
14 SHR Series Woodburning Fireplace 20001384 Installing Chimney in a Chase Refer to Page 5, Figure 4 for an illustration of a typical chase installation. CAUTION: Treatment of firestop spacers and construc- tion of chase may vary with type of building. These instructions are not a substitute for loca...
Page 15 - drywall finish
15 SHR Series Woodburning Fireplaces 20001384 FP1166surround flushwith finished wall12/20/01 djt Stud 2 x 4 Header Ledge Bracket Surround Must be Sealed with Noncombustible Material Noncombus- tible Decorative Facing Finished Wall FP1166 Fig. 25 Fireplace surround flush with finished wall. FP1277 SHR5...
Page 17 - Side Wall Protection; Examples of wall shield insulation:; or; Example of Determining; To determine the thickness required for any; new; Hearth Installation; Example for Common Brick
17 SHR Series Woodburning Fireplaces 20001384 Side Wall Protection Adjacent combustible side walls that are within dimen-sions shown in Figure 29 of fireplace opening must be protected with Wall Shield Model SP40 or a specifically built wall shield described in Figure 28.The special wall shield design...
Page 18 - Minimum Wall Clearances
18 SHR Series Woodburning Fireplace 20001384 FP532SHR Fig. 31 Combustible side wall protection and hearth extension dimensions. Minimum Wall Clearances WITH Noncombustible Surround Facing WITHOUT Noncombustible Surround Facing Minimum Hearth Extension Dimensions (for On-Site Construction) G H G J Se...
Page 19 - CSA draft requirements; Installing Line for Gas Logs; If installing an unvented gas log set, refer to statement below:
19 SHR Series Woodburning Fireplaces 20001384 removed from gas line tube to repack space around the pipe. Material should be inserted from outside of the fireplace and packed tightly to totally seal between the pipe and tube. Note: Gas pipe should not come in contact with any wood structures until it...
Page 20 - Damper Weld Assembly
20 SHR Series Woodburning Fireplace 20001384 1384 pts replacement parts 5/27/99 djt 7/14/99 removed clips,added push nut 1 2 3 4 5 6 7 8 a b c 9 10 11 d 12 13 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any tim...
Page 21 - Accessories; Accessory
21 SHR Series Woodburning Fireplaces 20001384 Description Designed to enclose the fireplace opening with glass doors allowing the fire to remain visible. Available in Polished, Brushed Brass, Black and Pewter Provides outside air for fuel conbustion in the firebox. This accessory must be installed befo...
Page 22 - Contemporary Flashing
22 SHR Series Woodburning Fireplace 20001384 Accessory Description Model No. Contemporary Flashing Contemporary Chase Top Termina-tion Contemporary Round Top Termina-tion Extended Round Top Chimney Sections Chimney Elbows Top Housing withUpper Baffle Attic Insulation Shield Required for contemporary ...
Page 23 - LIMITED WARRANTY & 30 YEAR PROTECTION PLAN; For MAJESTIC FIREPLACES
23 SHR Series Woodburning Fireplaces 20001384 � LIMITED WARRANTY & 30 YEAR PROTECTION PLAN For MAJESTIC FIREPLACES ® PRE-ENGINEERED Fireplace Systems CFM Corporation warrants its MAJESTIC FIREPLACES® Pre-En-gineered Fireplace (“Fireplace”) and the CFM Corporation supplied firegrate, glass doors, ...