Vermont Casting 2465 - Manual
Vermont Casting 2465 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Dutchwest Direct Vent / Natural Vent Gas Heater; Table of Contents
- Page 3 – General Information
- Page 4 – Dutchwest Direct Vent / Natural Vent Dimensions; CL; Dutchwest dimensions.; Attention
- Page 5 – Installation Requirements; Locating the Stove; We do not recommend the use of wallpaper; Dutchwest; Direct Vent System Only; A. Flat on corner wall; Possible stove locations.; Clearance Requirements; Always maintain required clear-
- Page 6 – Stove Clearance
- Page 7 – Input; Gas Specifications; Dutchwest Direct Vent/Natural Vent; High Elevations; Horizontal Termination -; Horizontal vent termination window.
- Page 8 – Vertical Termination - Direct Vent ONLY; NOTE: The restrictor plate supplied; A vertically terminated vent system must; Vertical vent termination window.; Vent Termination Clearances; IMPORTANT
- Page 9 – Venting Termination Clearances; • Venting terminals shall not be recessed into a wall or; Location of Vent Termination
- Page 10 – Canadian Installations; General Venting Information - Termination Location
- Page 11 – Termination clearances.; Venting Requirements - Natural Vent Only; Venting Runs; NOTE: When venting staight vertical, without any; Vent termination window - Natural Vent ONLY.; Outside Corner; Termination Clearances; with no side wall; of Caps
- Page 12 – Venting Requirements and Options -
- Page 13 – Install the Optional Fan; Fan kit components.; Remove the rear skirt insert panel at the bottom of; Remove rear skirt insert.; attach fan; Attach the fan assembly and the snapstat.
- Page 14 – Venting System Assembly - Direct Vent; For Canadian installations:; Install the Vent Adapter Pipe; Install the restrictor plate only if required for the vent-; Dry fit the Outer pipe assembly; attach inner pipe; Connect the inner starter with the next section of in-; attach inner assy; Attach inner assembly to flue collar.; attach inner assy
- Page 15 – Discard the inner starter pipe; dura vent; Simpson DuraVent - install inner adapter pipe.; DW dura vent; Simpson DuraVent - install outer adapter pipe.; Side Wall Termination Assembly; Vent Opening; CFM System; Locate vent opening.; Assemble the wall sleeve and firestop.
- Page 16 – For DuraVent pipe only:; DW; Determine the vertical pipe length.; measure thru wall; Measure the horizontal length.; install pipe thru wall; Install the horizontal pipe and wall plate parts.; install wall terminal; Install the vent terminal.
- Page 17 – Vent Termination Below Grade; If the; install snorkel; snorkel detail; Use extension brackets to mount snorkel against; Vent Assembly
- Page 18 – vent thru ceiling; Install firestops and attic insulation shield.; vent thru roof; Roof support and flashing.; Venting System Assembly - Natural Vent; Decorative 7” pipe may be fitted around the B-vent; Install the Vent Pipe
- Page 19 – Install draft hood adapter.; Install the Log Set; Stardance; Connect the Gas Supply Line; CAUTION
- Page 20 – Burner Information; Air Shutter Adjustment Instructions; In order to connect Natural Gas,; Air Shutter Adjustment; Model; Remove stove front.; Jefferson; Remove rear log bracket and left and right log
- Page 21 – Air shutter adjusted.; air shutter adjust; Be sure to maintain 90° angle at left burner leg.; Complete the Assembly; attach switch assy; Attach switch assembly to rear shroud.; attach switch; Attach switch wires to valve.
- Page 22 – Thermostat; Install the wall thermostat in the desired location and; Install the Stove Front; handle assy; Insert handle stub into hole in front. Secure with 3/8”; Install the front plate.
- Page 23 – Operation; Your First Fire; Pilot assembly location.; Flame & Temperature Adjustment; Flame adjustment knob for Honeywell valve.; Flame Characteristics; Pilot flame; Correct pilot and burner flame patterns.
- Page 24 – FOR YOUR SAFETY READ BEFORE LIGHTING; Follow the gas supplier’s instructions.; To Turn Off Gas To Heater; Lighting and Operating Instructions; Lighting Instructions; Euro SIT; Lighting instructions
- Page 25 – Troubleshooting / Honeywell #8420 Gas Control System; SYMPTOM
- Page 26 – Fuel Conversion Instructions; Attach the gas line to the left side of the valve.; Conversion Precautions; Honeywell Valve
- Page 27 – Pilot Orifice Conversion; Remove mounting screws, pressure regulator tower; SIT; gas conversion; Remove pilot orifice.; Remove pilot hood. (Your pilot may have a different; Gas Conversion; Remove pilot orifice.
- Page 28 – Replace burner. Slide the burner in at an angle; Table 2. Injector Orifice Size Matrix
- Page 29 – Maintenance; ERATE THE HEATER WITH DAMAGED LOGS.; Remove the stove front.; glass swivel latch; Release the latches to release the glass frame.
- Page 30 – Gasket Replacement; Determine the correct length of gasket by laying it; Check the Gas Flame Regularly; glass gasket detail; Wrap the gasket material around the outside edge of; Inspect the Vent System Annually; Correct flame pattern.; Stove Disassembly
- Page 31 – Wiring Diagrams; On/Off switch and optional thermostat circuit.; IF ANY OF THE ORIGINAL WIRE, AS; Draft hood adapter wiring.; AN; BLK; FK26 wiring diagram; Schematic Diagram
- Page 32 – Small Lava Rock Package
- Page 33 – Pilot Top Convertible; Fuel Conversion Kits
- Page 34 – Optional Accessories; Fan Kits; Refer to Page 13 for installation instructions.; Remote Controls; ON/OFF and Temperature; Decorative Rings
- Page 35 – LIMITED LIFETIME WARRANTY; BASIC WARRANTY; IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty, your
- Page 36 – Efficiency Ratings; CFM Corporation
DO NOT STORE OR USE
GASOLINE OR OTHER FLAM-
MABLE VAPORS AND LIQUIDS
IN THE VICINITY OF THIS OR
ANY OTHER APPLIANCE.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch;
do not use any phone in your
building.
• Immediately call your gas
supplier from your neighbor’s
phone. Follow the gas suppliers
instructions.
• If you cannot reach your gas
supplier call the fire department.
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING
PROPERTY DAMAGE, PER-
SONAL INJURY OR LOSS OF
LIFE.
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE
INSTALLER/CONSUMER
SAFETY INFORMATION
FOR YOUR SAFETY
Installation and service must
be performed by a qualified
installer, service agency or
the gas supplier.
This appliance may be installed in
an after market permanently located
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases unless a certified kit is
used.
Direct Vent / Natural
Vent Gas Heater
Models: 2465, 2466
1935
Dutchwest
gas stove
cover
5/03
Homeowner’s Installation
and Operating Manual
C E R T I F I E D
DESIGN
C ERTIFIE D
30001935 1/07 Rev. 11
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Dutchwest stove. IMPORTANT: Read all instructions and warnings carefully before starting ...
3 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 General Information The Dutchwest Direct Vent/Natural Vent Room Heater, Model Nos. 3070, 3071, 3072 and 3073, is a vented gas appliance listed to the ANSI standard Z21.88b-2001 and CSA-2.33b-2001 for Vented Room Heaters, and CSA 2.17-M91, Ga...
4 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935 Dutchwest Direct Vent / Natural Vent Dimensions CL Valve Inlet 23" (584mm) 6 ��� " (172mm) 24 ��� " (622mm) CL Valve Inlet 1935Dutchwest DV/NVdimensions5/15/03 28 ��� " (721mm) 12 ��� " (318mm) 17" (419mm) 4 ��� "...