Vermont Casting 2490 - Manual

Vermont Casting 2490

Vermont Casting 2490 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – Resolute Acclaim Woodburning Stove; Introduction; Save These Instructions.; Proposition 65 Warning:; Table of Contents
  • Page 3 – Specifications; Resolute Acclaim Model 2490; Resolute Acclaim dimensions.
  • Page 4 – Installation; What Kind of Chimney to Use; Standard chimney types.
  • Page 5 – Prefabricated Chimneys
  • Page 6 – The crimped end of; The thimble, made of either cermaic or metal, must be; Chimney connection is a freestanding installation.
  • Page 7 – Above A Fireplace; Double-check connector clearance from the ceiling.; Through A Fireplace; fireplace; Chimney connector enters chimney through the fire-; Check these
  • Page 8 – In the United States, the National Fire Protec-; Using a section of double-wall chimney with a 9”; An approved wall pass-through for Canada.
  • Page 9 – Floor Protection; the floor protector is required under; Floor Protection for Fireplace Installation; Rear exit floor dgrm; Supporting timbers under fireplace hearth are consid-; Canada; Required floor protector dimensions.
  • Page 10 – Keep the Stove a Safe Distance From; When the stove has no listed heat shield mounted; Wall Shields; wall shield construction; Approved wall shield construction.; Reversing the Flue Collar; Position the extension plate and flue collar in the
  • Page 11 – Secure the extension plate and flue collar with the; Fireplace Installations; mantel and; Fireplace Mantel and Trim Clearances; Measured from the stove top and sides; Protected; Maintain clearances to combustible components of
  • Page 12 – Protected Surface; Resolute Acclaim Clearance Chart
  • Page 13 – Unprotected Surfaces; RESOLUTE
  • Page 14 – Minimum Wall Shield Requirements for Common Installations
  • Page 15 – **To locate center of flue collar for corner installation, add 10
  • Page 16 – Alcove Installations; Cutaway perspective of alcove installation.; Alcove Ceiling plan; Reflected ceiling plan.; Floor plan. Sheetrock on front face butts to Durock©; Alcove front view; Front section: 65” minimum clearance to combus-; Alcove side section.
  • Page 17 – Stove Controls; Two Controls Operate the Stove; primary air control lever; Operation; damper handle; Unpack the Stove; Hardware Bag contents:; Install Stove Legs; Seville; Attach stove legs and leg levellers.; Two Ways to Add Logs; The Resolute Acclaim controls are conveniently
  • Page 18 – The; andirons; slip into pockets cast into the front of; glass; clear for fireviewing, but they assure proper; A look inside the firebox of the Resolute Acclaim.
  • Page 19 – Primary Air Settings; Air Setting; Resolute Accaim; Low; Variable settings for the primary air control between; How to Build and Sustain a Wood Fire
  • Page 20 – Reloading and Reviving a Wood Fire; Thermostat
  • Page 21 – Rules for Open Fire Viewing; Do not put any tool up; Remove and Store Ash Safely; Screen; Angle the screen to seat the top first, then push the
  • Page 23 – Creosote
  • Page 24 – Maintenance; Keep Your Stove Looking New and; Care of the Cast Iron Surface; Let the stove and glass cool completely.; Clean the Exhaust Channels; Remove the ashpan, the griddle and the andirons.; Remove left and right sealing plates.; Replace the grate sections.
  • Page 25 – Remove another washer if necessary.; Adjust door latch; The front door seal can be adjusted simply by adding; Damper adjustment; When the damper’s gasket becomes compressed
  • Page 26 – Replace Broken Glass Immediately; Resolute Acclaim Gaskets on Moving Parts; Remove gasket, then clean channel with wire brush.; Lay a bead of gasket cement then press gasket in
  • Page 27 – Two different gasekt sizes are used to seal the front; griddle gasket; A 5/16” wire mesh gasket seals the griddle to the
  • Page 28 – Inspect the Chimney Connector and; Check gasketing for wear, and replace if necessary.; Yearly Spring Cleaning:; Thoroughly clean the chimney.
  • Page 29 – Item Description; Left Griddle Quad
  • Page 31 – Warranty; Limited 3 Year Warranty; Limited 1 Year Warranty
  • Page 32 – CFM Corporation
Loading the manual

0893

Resolute Acclaim

Cover

Homeowner’s
Installation and
Operating Manual

For use in the
United States and Canada

Do Not Discard This Manual: Retain for Future Use

2000893 4/06 Rev. 16

Resolute Acclaim

Woodburning Stove

Model 2490

0893

SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, OPERATED AND MAIN-
TAINED, A HOUSE FIRE MAY RESULT.
TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. FAILURE TO
FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN
DEATH. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION
INSPECTION REQUIREMENTS IN YOUR AREA.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Resolute Acclaim Woodburning Stove; Introduction; Save These Instructions.; Proposition 65 Warning:; Table of Contents

2 Resolute Acclaim Woodburning Stove 2000893 Introduction Thank you for choosing a Vermont Castings Resolute Acclaim. Your stove is one of the finest available. It features high efficiency, non-catalytic performance, using space-age refractory material and the precisely calibrated delivery of air to a...

Page 3 - Specifications; Resolute Acclaim Model 2490; Resolute Acclaim dimensions.

3 Resolute Acclaim Woodburning Stove 2000893 R E S O L U T E A c c l a i m 25 ��� " (648 mm) 27 ��� " (699 mm) 26" (660 mm) 6" (152 mm) 23" (584 mm) 19 ��� " (495 mm) 12 ��� " (324 mm) 25" (635 mm) 21 ��� " (546 mm) 25" (635 mm) 19" (483 mm) 0893 Resolute ...

Page 4 - Installation; What Kind of Chimney to Use; Standard chimney types.

4 Resolute Acclaim Woodburning Stove 2000893 Installation SAFETY NOTICE: IF YOUR RESOLUTE ACCLAIM IS NOT PROPERLY INSTALLED, OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT. FOR SAFETY, FOLLOW ALL INSTALLATION, OPERA-TION AND MAINTENANCE DIRECTIONS. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRIC-TI...

Other Vermont Casting Models

All Vermont Casting Other