Vermont Casting 3358 - Manual

Vermont Casting 3358

Vermont Casting 3358 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 2 – Radiance Vent-Free Gas Heater; Table Of Contents
  • Page 3 – Installation & Operating Instructions; Read this owner’s manual carefully and
  • Page 4 – RUVSOD specs; Radiance Vent Free dimensions.; Radiance Vent Free Gas Heater Dimensions
  • Page 5 – Clearance Requirements; Minimum Clearances to; Minimum mantel clearance.; Alcove Clearances; Minimum wall clearances.; WARNING
  • Page 6 – Firebox weight / shipping; Unvented Heaters; Input; RUVSODRN; Inlet Minimum; Gas Inlet and Manifold Pressures; Natural
  • Page 7 – This heater must have fresh air for proper opera-; The following informa-; Space; is defined as the room in which you will install
  • Page 8 – W A R N I N G; Confined; Vent options to provide additional air.
  • Page 9 – Tools Required; DO NOT INSTALL DAMAGED LOGS.; Assembly Procedures; Remove the front plate.; Radiance; Lift screen from firebox.; RUVSOD
  • Page 10 – Install Optional Fan; Slide stove back just far enough to access rear leg; Carefully tip stove onto back legs. Leave pallet under; Loosen four phillips screws holding rear shroud as-
  • Page 12 – Disconnect power; If you are installing the fan kit after the stove is; JUV; Attach rheostat to control panel. Valve may look dif-; Install ON/OFF Switch; Run wires down back of stove, under bottom of rear; attach switch; Attach switch wires to valve; attach switch assy; Attach switch assembly to rear shroud.; Thermostat Wire / Gauge
  • Page 13 – Glass & Catalyst Installation; Thermostat; Optional Thermostat Wiring; injector orifice; Be sure injector orifices remain at 90° to the base.; pull frame latches; Attach glass latches.; RNVOD; Remove air shutter and discard.; Install catalytic combustor.
  • Page 14 – Install Log Set; NEVER test with an open flame.
  • Page 15 – Top View; Lava rock placement.; Install the left and right rear logs and the right log.; Radiance logs; Completed log installation.; Complete the Installation; Replace the front panel.; Attach the handle to the control door.
  • Page 16 – Operation; Your First Fire; handle holder; LO; Flame Characteristics
  • Page 17 – FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; To Turn Off Gas To Heater; Lighting And Operating Instructions; Lighting Instructions; Euro SIT; Lighting instructions
  • Page 18 – Troubleshooting; Honeywell Valve; Honeywell valve assembly.
  • Page 19 – Troubleshooting cont’d.; CONDITION; Correct LP Pilot Flame.; Pilot flame is lifting.
  • Page 20 – Maintenance; Remove the screen or glass panel.
  • Page 21 – Catalytic Combustor; Remove the front plate and top grille/screen.; Remove the catalytic combustor module.
  • Page 22 – a. Right Rear Log RUVSOD
  • Page 23 – Classic
  • Page 24 – Optional Accessories; Fan Kits
  • Page 27 – IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
  • Page 28 – CFM Specialty Home Products
Loading the manual

Radiance

Vent Free Gas Heater

Model RUVSOD: 3357, 3358, 3370
thru 3379

20004555 9/05 Rev. 12

Homeowner’s Installation

and Operating Manual

INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER

DESIGN

C ERTIFIE D

This is an unvented gas-fired heater.
It uses air (Oxygen) from the room
in which it is installed. Provisions for
adequate combust0ion and
ventilation air must be provided.
Refer to Page 7.

INSTALLER / CONSUMER

SAFETY INFORMATION

WARNING: If the information in this
manual is not followed exactly, a
fire or explosion may result causing
property damage, personal injury or
loss of life.

Please read this manual before
installing and using appliance.

Do not store or use gasoline or

other flammable vapors and

liquids in the vicinity of this or

any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any

appliance.

Do not touch any electrical
switch; do not use any phone
in your building.

Immediately call your gas

suppler from a neighbor’s

phone. Follow the gas

suppler’s instructions.

If you cannot reach your gas
supplier, call the fire

department.

Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.

410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777

www.majesticproducts.com • www.vermontcastings.com

CFM Specialty Home Products

RADIA

NCE

4555

Radiance

UVSOD

cover

7/24/01 djt

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Radiance Vent-Free Gas Heater; Table Of Contents

2 Radiance Vent-Free Gas Heater 20004555 Installation and Operating Instructions ...................................................................................... 3 Stove Dimensions ............................................................................................................... 4...

Page 3 - Installation & Operating Instructions; Read this owner’s manual carefully and

3 Radiance Vent-Free Gas Heater 20004555 Installation & Operating Instructions In order to ensure safe and effective installation, this unit must be installed only by a qualified agency, individual, firm, corporation or company that is experienced in the instal-lation, repair and servicing of this...

Page 4 - RUVSOD specs; Radiance Vent Free dimensions.; Radiance Vent Free Gas Heater Dimensions

4 Radiance Vent-Free Gas Heater 20004555 31" (787mm) 29 ��� " (756mm) R A D I A N C E 18 ��� " (465mm) 11" (279mm) 28 ��� " (717mm) 6 ��� " (165mm) 4555 RUVSOD specs 7/01 Drawing Not to Scale 4555 Supply Inlet Fig. 1 Radiance Vent Free dimensions. Radiance Vent Free Gas Heate...