Page 2 - Radiance Vent-Free Gas Heater; Table Of Contents
2 Radiance Vent-Free Gas Heater 20004555 Installation and Operating Instructions ...................................................................................... 3 Stove Dimensions ............................................................................................................... 4...
Page 3 - Installation & Operating Instructions; Read this owner’s manual carefully and
3 Radiance Vent-Free Gas Heater 20004555 Installation & Operating Instructions In order to ensure safe and effective installation, this unit must be installed only by a qualified agency, individual, firm, corporation or company that is experienced in the instal-lation, repair and servicing of this...
Page 4 - RUVSOD specs; Radiance Vent Free dimensions.; Radiance Vent Free Gas Heater Dimensions
4 Radiance Vent-Free Gas Heater 20004555 31" (787mm) 29 ��� " (756mm) R A D I A N C E 18 ��� " (465mm) 11" (279mm) 28 ��� " (717mm) 6 ��� " (165mm) 4555 RUVSOD specs 7/01 Drawing Not to Scale 4555 Supply Inlet Fig. 1 Radiance Vent Free dimensions. Radiance Vent Free Gas Heate...
Page 5 - Clearance Requirements; Minimum Clearances to; Minimum mantel clearance.; Alcove Clearances; Minimum wall clearances.; WARNING
5 Radiance Vent-Free Gas Heater 20004555 Clearance Requirements Minimum Clearances to Combustible Materials Maintain clearance, (empty space), between combus-tible materials and the heater as specified below. Hearth Requirements The Radiance Unvented heater must be installed on rigid flooring. If the ...
Page 6 - Firebox weight / shipping; Unvented Heaters; Input; RUVSODRN; Inlet Minimum; Gas Inlet and Manifold Pressures; Natural
6 Radiance Vent-Free Gas Heater 20004555 Firebox weight / shipping 175 lbs. The installation of your Radiance stove must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition. (EXCEPTION: Do not derate this appliance for alti...
Page 7 - This heater must have fresh air for proper opera-; The following informa-; Space; is defined as the room in which you will install
7 Radiance Vent-Free Gas Heater 20004555 Vent Free Features The Radiance RUVSOD, Model Nos. 3357, 3358, 3370 thru 3379, is an unvented gas heating appliance tested and listed to the ANSI standard Z21.11.2-2000. This appliance is specifically configured to burn either Natural Gas or Propane fuel, as in...
Page 8 - W A R N I N G; Confined; Vent options to provide additional air.
8 Radiance Vent-Free Gas Heater 20004555 W A R N I N G This heater shall not be installed in a confined space unless provisions are made for adequate combustion and ventilation air. W A R N I N G If the area in which the heater may be operated is smaller than that defined as an unconfined space, provid...
Page 9 - Tools Required; DO NOT INSTALL DAMAGED LOGS.; Assembly Procedures; Remove the front plate.; Radiance; Lift screen from firebox.; RUVSOD
9 Radiance Vent-Free Gas Heater 20004555 Read these instructions thoroughly before starting the assembly. Follow procedures in the order given. Inspect the stove for damage before starting the assembly. Do not install this stove if any damage is evident. Contact your dealer immediately. The Radiance...
Page 10 - Install Optional Fan; Slide stove back just far enough to access rear leg; Carefully tip stove onto back legs. Leave pallet under; Loosen four phillips screws holding rear shroud as-
10 Radiance Vent-Free Gas Heater 20004555 Install Optional Fan It is easiest to install the optional fan kit #2767/FK26, before the stove is moved to its final location or con-nected to the gas line. The fan consists of a blower assembly and a rheo-stat switch that are connected by a wire harness. Th...
Page 12 - Disconnect power; If you are installing the fan kit after the stove is; JUV; Attach rheostat to control panel. Valve may look dif-; Install ON/OFF Switch; Run wires down back of stove, under bottom of rear; attach switch; Attach switch wires to valve; attach switch assy; Attach switch assembly to rear shroud.; Thermostat Wire / Gauge
12 Radiance Vent-Free Gas Heater 20004555 MOTOR SNAPSTAT ON/OFF RHEOSTAT WHT WH T BLK BLK BLK GR N BLK POWER ST196 FK26 fan diangram 11/99 Fig. 15 #2767 / FK26 Fan Wiring Diagram Disconnect power before servicing. ST196 The optional fan kit is equipped with a three-prong (grounding) plug for your pr...
Page 13 - Glass & Catalyst Installation; Thermostat; Optional Thermostat Wiring; injector orifice; Be sure injector orifices remain at 90° to the base.; pull frame latches; Attach glass latches.; RNVOD; Remove air shutter and discard.; Install catalytic combustor.
13 Radiance Vent-Free Gas Heater 20004555 Glass & Catalyst Installation CAUTION: Air shutter must be removed when installing glass and catalyst for proper operation. 1. Remove left and right log bracket assembly by unfastening the two screws which hold the burner in place. Loosen the screw on th...
Page 14 - Install Log Set; NEVER test with an open flame.
14 Radiance Vent-Free Gas Heater 20004555 Install Log Set 1. Remove the logs from their packaging, and inspect each piece for damage. DO NOT INSTALL DAM- AGED LOGS. 2. Install the rear left log by placing it on the sheet metal shelf at the back of the firebox. (Fig. 23) The log should touch the back ...
Page 15 - Top View; Lava rock placement.; Install the left and right rear logs and the right log.; Radiance logs; Completed log installation.; Complete the Installation; Replace the front panel.; Attach the handle to the control door.
15 Radiance Vent-Free Gas Heater 20004555 5. Loosely sprinkle the lava rocks directly on top of the burner just behind decorative grate. (Fig. 25) Use the lava rock to cover brackets on the burner. Do not place lava rocks toward back of burner. The lava rock is shipped inside the bag assembly. LG160...
Page 16 - Operation; Your First Fire; handle holder; LO; Flame Characteristics
16 Radiance Vent-Free Gas Heater 20004555 Operation The Radiance is shipped with the operable door front plate. The stove may be operated with the doors either open or closed. To open the front doors, insert the handle provided into the door latch stub and turn it to the right and up. (Fig. 28) When...
Page 17 - FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; To Turn Off Gas To Heater; Lighting And Operating Instructions; Lighting Instructions; Euro SIT; Lighting instructions
17 Radiance Vent-Free Gas Heater 20004555 3. Open control access panel.4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace.3. For MN/MP/TN/TP appl...
Page 18 - Troubleshooting; Honeywell Valve; Honeywell valve assembly.
18 Radiance Vent-Free Gas Heater 20004555 Troubleshooting Follow these procedures in the order presented. W A R N I N G TURN OFF HEATER AND ALLOW TO COOL COMPLETELY BEFORE SERVICING. CONDITION POSSIBLE CAUSE SOLUTION No spark at pilot when Ignitor is operated. 1. Ignition Electrode is disconnected f...
Page 19 - Troubleshooting cont’d.; CONDITION; Correct LP Pilot Flame.; Pilot flame is lifting.
19 Radiance Vent-Free Gas Heater 20004555 Troubleshooting cont’d. CONDITION POSSIBLE CAUSE SOLUTION Pilot lights but flame goes out when Control Knob is released. 1. Control Knob not fully depressed or held in long enough. 2. Gas supply line shut-off valve is not fully open. 3. Thermocouple connectio...
Page 20 - Maintenance; Remove the screen or glass panel.
20 Radiance Vent-Free Gas Heater 20004555 The following procedures will help ensure that your heater continues to perform safely and efficiently. Firebox Cleaning and Inspection Cleanliness is critical to correct operation of the heater. The log set, burner, valve controls and air circulation areas m...
Page 21 - Catalytic Combustor; Remove the front plate and top grille/screen.; Remove the catalytic combustor module.
21 Radiance Vent-Free Gas Heater 20004555 Catalytic Combustor The combustor should be cleaned annually to ensure optimal performance. Follow the procedure below. Remove the Combustor Module 1. Be sure the heater is COLD. 2. Remove the front plate, top grille and screen. (Fig. 36) 3. Use the phillips...
Page 22 - a. Right Rear Log RUVSOD
22 Radiance Vent-Free Gas Heater 20004555 PILOT ON OFF PILOT ADJ LO HI 1a 1b 1c 2 4 6 7 13 3 4555 RUVSOD PARTS 7/24/01 djt 23 8 16 17 18 5 10a,b 21 19 9 20 24a,b, c,d 11a 11b 15 25 27 28 29 22 14 12a,b 30 4555 CFM Specialty Home Products reserves the right to make changes in design, materials, speci...
Page 23 - Classic
23 Radiance Vent-Free Gas Heater 20004555 Radiance Vent Free Gas Heater (RUVSOD) Models 3357, 3358, 3370 thru 3379 (continued) Ref. Description RUVSOD 8. Handle Package, Ceramic w/Screw 0004342 9. Damper Steel Handle/Screw 5004265 10a. Valve NG Honeywell - VS84212003 10000235 10b. Valve LP Honeywell...
Page 24 - Optional Accessories; Fan Kits
24 Radiance Vent-Free Gas Heater 20004555 Optional Accessories Fan Kits FK26 Fan The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox tem-perature rises above and falls below a preset tempera-...
Page 27 - IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
27 Radiance Vent-Free Gas Heater 20004555 BASIC WARRANTY CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of...
Page 28 - CFM Specialty Home Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www.majesticproducts.com • www.vermontcastings.com CFM Specialty Home Products