Vanguard VN2550ITB - Manual
Vanguard VN2550ITB – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – VENT-FREE NATURAL GAS HEATER; Carbon Monoxide Poisoning:; Early signs; WARNINGS; DANGER: Carbon monoxide
- Page 3 – OWNER’S MANUAL; LOCAL CODES; American National Standards Institute, Inc.; SAFETY DEVICE; UNPACKING; Remove heater from carton.
- Page 4 – Unusually Tight Construction; per
- Page 5 – Determining if You Have a Confined or Unconfined Space
- Page 6 – Figure 3 - Ventilation Air from Outdoors; Ventilation Air From Outdoors; Do not provide openings; Figure 2 - Ventilation Air from Inside Building
- Page 7 – INSTALLATION; CHECK GAS TYPE; WARNING: Never install the
- Page 8 – Marking Screw Locations; Figure 8 - Mounting Bracket Clearances; Only mark last hole on each end; WARNING: Maintain minimum; Attaching to wall stud; Attaching To Wall Stud:; Mounting Bracket; Figure 7 - Removing Front Panel Of Heater; Removing Front Panel Of Heater; Figure 6 - Mounting Bracket; Attach thermostat sensing bulb; Attaching To Wall Anchor:; This method
- Page 9 – Attaching To Wall Stud Method; For attaching mounting bracket to wall studs; Attaching To Wall Anchor Method; Fold wall anchor as shown in Figure 9.; Figure 9 - Folding Anchor; Mark screw locations on wall.
- Page 10 – Figure 13 - Gas Connection; WARNING: A qualified service; Typical Inlet Pipe Diameters; Hold pressure regulator; WARNING : Never connect; Install an equipment shutoff
- Page 11 – WARNING: Never use an open; Figure 14 - Equipment Shutoff Valve; Figure 15 - Checking Gas Joints; Correct all leaks at once.
- Page 12 – LIGHTING; Figure 16 - Thermostat Control Knob In The OFF Position; FOR YOUR SAFETY
- Page 13 – WARNING: When running; Control; Shutting Off Heater
- Page 14 – CAUTION: You must keep; BURNER FLAME PATTERN; Figure 21 - Correct Burner Flame Pattern; PILOT FLAME PATTERN; Figure 19 - Correct Pilot Flame Pattern; Figure 20 - Incorrect Pilot Flame Pattern; CABINET; Air Passageways; Figure 23 - Pilot Inlet Air Hole
- Page 15 – TROUBLESHOOTING; OBSERVED PROBLEM; All troubleshooting items are listed in
- Page 17 – POSSIBLE CAUSE; IMPORTANT; Heater produces unwanted odors; REMEDY
- Page 19 – PARTS LIST; KEY
- Page 22 – SPECIFICATIONS; When Gas Pressure Is Too Low; PARTS UNDER WARRANTY
- Page 23 – ACCESSORIES; FLOOR MOUNTING STAND
- Page 24 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; LIMITED WARRANTY; INTERNATIONAL; NOT A UPC
®
VN1800ITB
and
VN2550ITB
Save this manual for future reference.
INFRARED VENT-FREE NATURAL GAS HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal in-
jury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed by
a qualified installer, service agency, or the
gas supplier.
WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it
is installed. Provisions for ad-
equate combustion and venti-
lation air must be provided.
Refer to
Air For Combustion
and Ventilation on page 4 of
this manual.
WARNING: Improper installa-
tion, adjustment, alteration,
service, or maintenance can
cause injury or property dam-
age. Refer to this manual for
correct installation and opera-
tional procedures. For assis-
tance or additional informa-
tion consult a qualified in-
staller, service agency, or the
gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufac-
tured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 104246 VENT-FREE NATURAL GAS HEATER ® 1. This appliance is only for use with thetype of gas indicated on the rating plate.This appliance is not convertible for usewith other gases. 2. If you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not touch any electrical switch; do...
3 104246 OWNER’S MANUAL PRODUCTIDENTIFICATION LOCAL CODES Install and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of National Fuel Gas CodeANS Z223.1, also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broad...
4 104246 VENT-FREE NATURAL GAS HEATER ® AIR FORCOMBUSTION ANDVENTILATION Today’s homes are built more energy effi-cient than ever. New materials, increasedinsulation, and new construction methodshelp reduce heat loss in homes. Home ownersweather strip and caulk around windows anddoors to keep the co...