- Page 2 – - A pliable sealant for use around
- Page 3 – OWNER’S MANUAL; INTRODUCTION; WARNING: Installation and; BEFORE YOU BEGIN; YOU MAY CAUSE A SAFETY
- Page 4 – FRAMING; Minimum clearances to combustibles are:; MANTEL CLEARANCES; inches; Spacer; TOP VIEW; Drywall
- Page 5 – GENERAL VENTING; Figure 12 - Vent Opening Height; Continued
- Page 6 – Figure 13 - Minimum Clearances for Vent Terminations
- Page 7 – WARNING: This gas fireplace; INSTALLATION PLANNING; For Horizontal Termination:; Installing Vent System in a Chase; WARNING: Never run the vent
- Page 8 – The location; Figure 15 - Snorkel Termination with Drainage Pipe; WARNING: Do not recess vent; Snorkel
- Page 9 – Vent Opening; Figure 17 - Vent Opening Requirements; Figure 19 - Installing Vinyl Siding Standoff; Note
- Page 10 – Elbow; Horizontal Venting; FGFVK Vent Kit Shown
- Page 11 – Venting with Two 90; Elbows with Termination at 90
- Page 12 – If an offset is needed to avoid; Cathedral Ceiling Installation; Figure 24 - Offset with Wall Strap and 45; Figure 25 - Installing Firestop
- Page 13 – Vertical Termination Configurations; Figure 28 - Vertical Rigid Venting Configuration Using Two 90; Venting with One 90; Figure 29 - Vertical Rigid Venting Configuration Using One 90
- Page 14 – Vertical Venting; Figure 30 - Vertical Rigid Venting Configuration Using Two 90; RVF Kit Shown
- Page 15 – Number Description; Number Description; Vanguard Rigid Venting
- Page 16 – Figure 33 - Wall Switch Wiring Diagram; If using an optional wireless hand-; Figure 36 - Installing Battery in Receiver; INSTALLATION; Figure 32 - Removing Louver; Glass; Installing Receiver; Battery Clip
- Page 17 – Attach terminal wires to the battery; The appliance and its indi-; Key; Figure 39 - Sediment Trap; Minimum Input Rating:
- Page 18 – Figure 41 - Removing Glass Door; GAS SUPPLY TESTING; CAUTION: Do not connect; Figure 40 - Millivolt Control Valve; Pilot Gas Line - Do Not Kink
- Page 19 – Carefully remove the log set.; CAUTION: Make certain the; DECORATIVE FACING; Left; Figure 47 - Correct Pilot Flame Pattern
- Page 21 – Lighting; Thermostat Control Operation
- Page 22 – Do not leave the se-; Shows Temperature Setting
- Page 23 – SERVICE HINTS; When Gas Pressure Is Too Low; WIRING DIAGRAM; PARTS UNDER WARRANTY
- Page 24 – TROUBLESHOOTING; OBSERVED PROBLEM; WARNING: Turn off heater
- Page 25 – POSSIBLE CAUSE
- Page 28 – ACCESSORIES; PILOT ASSEMBLY
- Page 29 – GAS CONTROL VALVE
- Page 30 – For information about this warranty write:; INTERNATIONAL; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC
Save this manual for future reference.
OWNER’S OPERATION AND INSTALLATION MANUAL
DIRECT-VENT GAS FIREPLACE HEATER
®
®
VDVF36PN/PP (PENINSULA) AND VDVF36STN/STP (SEE THRU)
This appliance may be installed in an aftermarket* permanently located, manufactured (mobile) home, where not
prohibited by state or local codes.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases, unless a certified kit is used.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS :
• Do not try to light any appliance.
• Do not touch any electrical switch;
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
SAVE THIS BOOK
This book is valuable. In addition to instructing
you on how to install and maintain your appli-
ance, it also contains information that will
enable you to obtain replacement parts or
optional accessory items when needed. Keep
it with your other important papers.
WARNING: Improper installation,
adjustment, alteration, service, or
maintenance to this appliance can
cause injury or property damage.
Refer to this manual. For assistance
or additional information consult a
qualified installer, service agency,
or the gas supplier.
CHECK LOCAL CODES PRIOR TO INSTALLATION
WARNING: If the information in these instruc-
tions is not followed exactly, a fire or explosion
may result causing property damage, personal
injury, or loss of life.
WARNING: This Direct-Vent Gas
Fireplace Heater series is intended
for use with Natural or Propane/LP
gas only. Do not attempt to burn any
solid fuels in these appliances.
(Peninsula
Shown)
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 105706 DIRECT-VENT GAS FIREPLACE HEATER VDVF36P and VDVF36ST Series ® FRONT VIEW 30 (76cm) (Opening) 23 5 / 8 (60cm) 25 (64cm) RIGHT SIDE 22 5 / 8 (57cm) 43 1 / 8 (110cm) 32 (81cm) (Opening) 1 7 / 8 (5cm) 1 1 / 4 (3cm) BACK VIEW 39 3 / 4 (101cm) 26 3 / 8 (67cm) 3 (8cm) 1 (3cm) 2 (5cm) 3 (8cm) 22 5...
3 105706 OWNER’S MANUAL Models VDVF36PN/PP series are three-sided direct-vent gas fireplace heaters witha sealed combustion chamber. ModelsVDVF36STN/STP series are two-sided di-rect-vent gas fireplace heaters with a sealedcombustion chamber. All models use a mil-livolt gas control and a millivolt ig...
4 105706 DIRECT-VENT GAS FIREPLACE HEATER VDVF36P and VDVF36ST Series ® FRAMING Once the final location has been determined,observing height clearances for vent termi-nation, you may construct framing usingdimensions shown in Figures 7 through 9,page 5, depending on your installation. If the applian...