Vanguard 107156-01E.pdf - Manual

Vanguard 107156-01E.pdf

Vanguard 107156-01E.pdf – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
Page: / 38

Table of Contents:

  • Page 2 – SAFETY INFORMATION; DANGER: Carbon monoxide poisoning may lead; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; WARNING: Any change to this heater or its; TABLE OF CONTENTS
  • Page 3 – PRODUCT IDENTIFICATION; Figure 1 - Log Base Assembly, Split Oak Set; Continued
  • Page 4 – PRODUCT FEATURES; OPERATION; WARNING: This heater shall not be installed in a; LOCAL CODES; American National Standards Institute, Inc.; UNPACKING; The hood is located in the packing on the right; WARNING: Do not remove the data plates at-
  • Page 5 – Unusually Tight Construction; per kw) of the aggregate input rating; AIR FOR COMBUSTION AND VENTILATION
  • Page 6 – Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; Figure 4 - Ventilation Air from Outdoors; WARNING: If the area in which the heater may be
  • Page 7 – Your fireplace is designed to be used in zero clearance; CAUTION: This fireplace creates warm air cur-; Figure 5 - Installing Hood; INSTALLING HOOD; Vent-free heaters add moisture to the air. Although; CHECK GAS TYPE; INSTALLATION
  • Page 8 – Figure 7 - Attaching Brass Trim to Fireplace; If you are recessing the firebox in a wall, do not attach; CONVENTIONAL FIREPLACE INSTALLATION; WARNING: Maintain the minimum clearances. If; Figure 8 - Minimum Clearance for Combustible to Wall
  • Page 9 – Figure 9 - Placing Hearth Base Accessory Against Wall; Figure 10 - Installing Cabinet Mantel; Bushing may be; Figure 12 - Inserting Fireplace Into Cabinet Mantel
  • Page 10 – Mantel Clearances for Built-In Installation; Figure 14 - Rough Opening for Installing in Corner; Actual; Plug electrical cord into electrical outlet installed in step 2.
  • Page 11 – WARNING: A qualified service person must con-; Figure 17 - External Regulator with Vent Pointing Down; Installation Items Needed; Figure 18 - Gas Connection; WARNING: Use pipe joint sealant that is resistant; Install equipment shutoff valve in an accessible
  • Page 12 – Pressure Testing Gas Supply Piping System; Correct all leaks at once.; CHECKING GAS CONNECTIONS; WARNING: Test all gas piping and connections; • Phillips screwdriver; CONNECTING FIREPLACE TO GAS SUPPLY; CAUTION: Do not pick up log base assembly by; Figure 19 - Removing Log Base Assembly From Fireplace
  • Page 13 – Figure 21 - Equipment Shutoff Valve; Figure 22 - Checking Gas Joints; Pressure Testing Fireplace Gas Connections; Make sure control knob of fireplace is in the OFF position.; WARNING: Failure to position the parts in accor-; INSTALLING LOGS; CAUTION: Do not remove the data plates attached
  • Page 14 – WARNING: If you do not follow these instructions; FOR YOUR SAFETY; OPERATING FIREPLACE; WARNING: You must operate this fireplace with; Figure 27 - Installing Fireplace Screen; THERMOSTAT-CONTROLLED MODELS
  • Page 15 – CAUTION: Do not try to adjust heating levels by; Figure 28 - Control Knob and Ignitor Button Location; Shutting Off Fireplace; Shutting Off Burners Only (pilot stays lit); OPERATING FIREPLACE - Thermostat-Controlled Models
  • Page 16 – Figure 30 - Control Knob and Ignitor Button Location; OPERATING FIREPLACE - Manually-Controlled Models; Note; : If pilot does not stay lit, contact a qualified service; MANUALLY-CONTROLLED MODELS
  • Page 17 – Blower Kit Model GA3750 Series; WARNING: Do not operate heater between locked
  • Page 18 – INSPECTING BURNERS; PILOT FLAME PATTERN; Figure 32 - Correct Pilot Flame Pattern; FRONT BURNER FLAME PATTERN; WARNING: If front burner flame pattern shows; Figure 35 - Incorrect Front Burner Flame Pattern
  • Page 19 – WARNING: Turn off fireplace and let cool before; Blow air through the ports/slots and holes in the burner.; Figure 36 - Injector Holder On Outlet Burner Tube; Figure 37 - Pilot Inlet Air Hole; LOGS; • If you remove logs for cleaning, refer to Installing Logs, pages; CLEANING AND MAINTENANCE
  • Page 20 – POSSIBLE CAUSE; WARNING: Turn off fireplace; All troubleshooting items are listed in; TROUBLESHOOTING
  • Page 21 – OBSERVED PROBLEM; nance, page 19) or replace burner orifice
  • Page 22 – IMPORTANT
  • Page 23 – SPECIFICATIONS; PARTS UNDER WARRANTY; SERVICE HINTS; When Gas Pressure Is Too Low; CAUTION: Label all wires prior to disconnection; TECHNICAL SERVICE
  • Page 24 – ILLUSTRATED PARTS BREAKDOWN
  • Page 25 – PARTS LIST; LOG BASE ASSEMBLY; PART NUMBER
  • Page 32 – Shown with optional laminate mantel trim accessory.; CORNER HEARTH BASE; CABINET MANTEL; ACCESSORIES
  • Page 33 – LAMINATE TRIM FOR HEARTH OR MANTEL; G3002J Series - Jade Marble Laminate Mantel Trim; Ceramic fiber firebox liner adds the look of real brick.
  • Page 34 – NOTES
  • Page 35 – OWNER'S REGISTRATION FORM
  • Page 36 – Postage; T APE
  • Page 38 – Model; LIMITED WARRANTY VENT-FREE PROPANE/LP GAS FIREPLACE; KEEP THIS WARRANTY; WARRANTY INFORMATION; NOT A UPC
Loading the manual

UNVENTED (VENT-FREE)
PROPANE/LP GAS FIREPLACE

OWNER’S OPERATION AND
INSTALLATION MANUAL

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

;;;;;;

;;;;;;

;;;;;;

;;;;;;

;;;;;;

;;;;;;

;;;;;;

;;;;;;

;;;;;;

QQQQQQ

QQQQQQ

QQQQQQ

QQQQQQ

QQQQQQ

QQQQQQ

QQQQQQ

QQQQQQ

QQQQQQ

¢¢¢¢¢¢

¢¢¢¢¢¢

¢¢¢¢¢¢

¢¢¢¢¢¢

¢¢¢¢¢¢

¢¢¢¢¢¢

¢¢¢¢¢¢

¢¢¢¢¢¢

¢¢¢¢¢¢

;;;

;;;

;;;

QQQ

QQQ

QQQ

¢¢¢

¢¢¢

¢¢¢

;;;;;;;;;;

;;;;;;;;;;

;;;;;;;;;;

QQQQQQQQQQ

QQQQQQQQQQ

QQQQQQQQQQ

¢¢¢¢¢¢¢¢¢¢

¢¢¢¢¢¢¢¢¢¢

¢¢¢¢¢¢¢¢¢¢

Shown with

optional cabinet

mantel, hearth

base, and trim

accessories.

WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other
appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any

phone in your building.

• I m m e d i a t e l y c a l l y o u r g a s s u p p l i e r f r o m a

neighbor’s phone. Follow the gas supplier’s in-
structions.

• If you cannot reach your gas supplier, call the fire

department.

— Installation and service must be performed by a quali-

fied installer, service agency, or the gas supplier.

WARNING: Improper installation, ad-
justment, alteration, service, or main-
tenance can cause injury or prop-
erty damage. Refer to this manual
for correct installation and opera-
tional procedures. For assistance or
additional information consult a
qualified installer, service agency,
or the gas supplier.

WARNING: This is an unvented gas-
fired heater. It uses air (oxygen) from
the room in which it is installed.
Provisions for adequate combustion
and ventilation air must be provided.
Refer to

Air for Combustion and Ven-

tilation section on page 4 of this
manual.

Variable Manually-

Controlled Model

VSGF28PVA

Thermostatically-

Controlled Model

VSGF28PTC

with Split Oak Logs

This appliance may be installed in an aftermarket,* permanently located, manufactured
(mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appli-
ance is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

®

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SAFETY INFORMATION; DANGER: Carbon monoxide poisoning may lead; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; WARNING: Any change to this heater or its; TABLE OF CONTENTS

107156-01E F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 2 Due to high temperatures, the appliance should belocated out of traffic and away from furniture anddraperies. Do not place clot...

Page 3 - PRODUCT IDENTIFICATION; Figure 1 - Log Base Assembly, Split Oak Set; Continued

107156-01E F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 3 3 PRODUCT IDENTIFICATION Figure 1 - Log Base Assembly, Split Oak Set Rear Log RearBurner Crossover Log Middle Log Front Log Fro...

Page 4 - PRODUCT FEATURES; OPERATION; WARNING: This heater shall not be installed in a; LOCAL CODES; American National Standards Institute, Inc.; UNPACKING; The hood is located in the packing on the right; WARNING: Do not remove the data plates at-

107156-01E F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 4 AIR FOR COMBUSTION ANDVENTILATION Today’s homes are built more energy efficient than ever. New mate-rials, increased insulation...

Other Vanguard Models

All Vanguard Other