US Stove Company ASA7 - Manual
US Stove Company ASA7 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – SAFETY PRECAUTIONS; OR
- Page 3 – Shaker Handle Assembly:; Attach to the unit with the bolts removed in step 1.; Flue Collar Assembly:
- Page 4 – MASONRY CHIMNEY REQUIREMENTS
- Page 5 – Ceiling
- Page 6 – COMBUSTIBLE WALL
- Page 8 – DOES NOT PASS THROUGH A COMBUSTIBLE WALL
- Page 9 – METAL PREFABRICATED CHIMNEY REQUIREMENTS; A straight up chimney is best because it will draw better.; METAL PREFABRICATED CHIMNEY INSTALLATION
- Page 12 – HEATER INSTALLATION; MINIMUM CLEARANCES TO COMBUSTIBLE WALL AND CEILINGS
- Page 13 – CAUTION: READ ALL INSTRUCTIONS BEFORE INSTALLING THE HEATER.; TO INSTALL THE HEATER:; Place the heater on the floor protector as shown in Figure 9.; WHEN CHIMNEY CONNECTOR EXITS
- Page 15 – OPERATING INSTRUCTIONS
- Page 16 – Ashes; Do not shake or stir with a low fire.; Loading
- Page 17 – Serious damage to the stove can occur from overheating.; Safety; LARGER) BITUMINOUS OR ANTHRICITE COAL
- Page 18 – Repair Parts
- Page 19 – PARTS LIST; Complete Shaker Grate Assembly; Feed Door Glass Replacement
- Page 20 – THE PART DESCRIPTION; HOW TO ORDER REPAIR PARTS; UNITED STATES STOVE COMPANY; U S
USSC
1
CAUTION:
READ ALL INSTRUCTIONS CARE-
FULLY BEFORE STARTING THE
INSTALLATION OR OPERATING
THE HEATER
IMPROPER INSTALLATION MAY VOID
YOUR WARRANTY
DO NOT USE THIS HEATER
IN A MOBILE HOME OR TRAILER
851523
C
R
U S
UNITED STATES STOVE COMPANY
227 Industrial Park Road
P.O.Box 151
South Pittsburg, TN 37380
(423) 837-2100
Owner’s
Manual
4027 & ASA7
Free-Standing Coal Heater
This is a
COAL ONLY
Room Heater
Tested to: UL 1482 and CAN/ULC S627-M93
COMPANY
UN
ITE
D STATES STOV
E
C
S
S
U
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 USSC SAFETY PRECAUTIONS PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW HEATING APPLIANCE. FAIL-URE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. THIS HEATING APPLIANCE SHOULD BE INSTALLED ONLY BY AN EXPERIENCED COAL HEATER INSTALLER. IFTHIS...
USSC 3 Before Assembly, inspect the heater thoroghly formissing parts or shipping damage. If any damage ormissing parts are detected, report it to your heater dealer. DO NOT INSTALL OR USE A DAMAGED ORINCOMPLETE HEATER Shaker Handle Assembly: 1. First, remove the two(2) bolts from the left side of t...
4 USSC FIGURE 1 -MASONRY CHIMNEYREQUIREMENTS FLUE MINIMUM 1/2" AIR SPACE FOUNDATION CHIMNEY WALL 4"NOMINAL 5/8" FIRECLAY ORSTAINLESS STEALFLUE LINER If the heater is to be connected to a masonry chimney, the heater should not be installed until it is determined that thechimney is safe fo...