Page 2 - Table of Contents
2 USSC TABLE OF CONTENTS .............................................................................................. 2SAFETY PRECAUTIONS ........................................................................................... 3SPECIFICATIONS .......................................................
Page 3 - Safety Precautions; Use of outside air is required for this unit.
USSC 3 Safety Precautions IMPORTANT: Read this entire manual before installingand operating this product. Failure to do so may resultin property damage, bodily injury, or even death.Proper installation of this stove is crucial for safe andefficient operation. Install vent at clearances specified by ...
Page 4 - Specifications; Heating Specifications
4 USSC Specifications Heat Output 1 48,000 BTU/hr. Heating Capacity 2 800 - 2,000 sq. ft. Fuel Burn Rate 3 2.0 - 6.0 lbs./hr. Burn Time (lowest setting) 5500 - 60 hrs. 5500XL - 160 hrs. Hopper Capacity 5500 - 150 lbs. 5500XL - 320 lbs. Heating Specifications 5500 5500XL Height 34 in. 47 1/4 in. Widt...
Page 5 - INSTALLATION OPTIONS; Freestanding Unit; Installation; IMPROPER INSTALLATION:; FLOOR PROTECTION
USSC 5 INSTALLATION OPTIONS Read this entire manual before you install and use your King/Ashley stove. Failure to follow instructionsmay result in property damage, bodily injury, or even death! (See specific installation details for clearances and other installation requirements) A Freestanding Unit...
Page 6 - CLEARANCES; NOTE: Distance “C” on the left-hand side of your; TABLE 1; ALCOVE INSTALLATION; THIS INSTALLATION IS NOT APPLICABLE
6 USSC Installation CLEARANCES Your King/Ashley stove has been tested and listed for installation in residential, mobile home, and alcove applications inaccordance with the clearances given in FIGURES 3-5 and TABLE 1. NOTE: Distance “C” on the left-hand side of your King/Ashley stove may need to be ...
Page 7 - VENTING REQUIREMENTS; Install vent at clearances specified by the vent manufacturer.; MAXIMUM VENTING DISTANCE; We recommend the use of Simpson Dura-Vent; PELLET VENT INSTALLATION
USSC 7 Installation VENTING REQUIREMENTS Install vent at clearances specified by the vent manufacturer. Do not connect the pellet vent to a vent serving any other appliance or stove. Do not install a flue damper in the exhaust venting system of this unit. The following installation guidelines must b...
Page 8 - VENT TERMINATION CLEARANCES:; Minimum 1-foot clearance above any door or window that opens.
8 USSC Installation VENT TERMINATION CLEARANCES: A) Minimum 4-foot clearance below or beside any door or window that opens. B) Minimum 1-foot clearance above any door or window that opens. C) Minimum 3-foot clearance form any adjacent building. D) Minimum 7-foot clearance from any grade when adjacen...
Page 9 - THROUGH THE WALL INSTALLATION; Your; THROUGH THE ROOF/CEILING INSTALLATION; FIGURE 7
USSC 9 Installation THROUGH THE WALL INSTALLATION (RECOMMENDED INSTALLATION) To vent the unit through the wall, connect the pipe adapterto the exhaust motor adapter. If the exhaust adapter is atleast 18-inches above ground level, a straight section ofpellet vent pipe can be used through the wall. Yo...
Page 10 - OUTSIDE AIR SUPPLY; The outside air pipe on your; FIGURE 9; FIGURE 8; SPECIAL MOBILE HOME REQUIREMENTS; WARNING! - DO NOT INSTALL IN A SLEEPING ROOM; The stove must be permanently attached to the floor.
10 USSC Installation OUTSIDE AIR SUPPLY (optional) Depending on your location and home construction, outside air may be necessary for optimal performance. Metal pipe (solid or flexible) must be used for the outside air installation. PVC pipe is NOT approved and should NEVERbe used. A wind shield ove...
Page 11 - HOW YOUR STOVE WORKS; Operation
USSC 11 Do not operate your stove with the viewing door open. The auger will not feed pellets under thesecircumstances and a safety concern may arise from sparks or fumes entering the room. This heater is designed and approved for premium hardwood pellet fuel only. Any other type of fuel burnedin th...
Page 12 - CONTROL PANEL; “ON”; UNIT PREPARATION; PERFORMING A “DRY RUN”
12 USSC CONTROL PANEL Turning the stove OFF/ON, as well as adjustments for the fuelfeed rate and room air fan speed are performed by pressingthe appropriate button(s) on the control panel which is locatedon the lower left-hand side of your King/Ashley stove (see FIGURE 10). Pressing the “ON” button ...
Page 13 - SHUT DOWN PROCEDURE
USSC 13 SHUT DOWN PROCEDURE Press the “OFF” button on the control pad to put the stove in shut down mode. At this time, the red light above the pad will illuminate. Once this is done, the auger will stop feeding pellets, but the room air fan, exhaust blower, and bottomauger will continue to operate....
Page 14 - Maintenance; DAILY OPERATION
14 USSC Maintenance Operation DAILY OPERATION The hopper and stove top will be hot during operation; therefore, you should always use some type of handprotection when refueling your stove. Never place your hand near the auger while the stove is in operation. This unit should be filled when the hoppe...
Page 15 - Dealer to obtain a can of suitable high-temperature paint.; A yearly servicing and cleaning by your Authorized “
USSC 15 INTERIOR CHAMBERS Periodically remove and clean the burnpot and the area inside the burnpot housing. In particular it is advisable to cleanout the holes in the burnpot to remove any build up that may prevent air from moving through the burn pot freely. If a vacuum is used to clean your stove...
Page 16 - Trouble Shooting; PROBLEM
16 USSC Trouble Shooting Disconnect the power cord before performing any maintenance! NOTE: Turning the ON/OFF Switch to”OFF” does not disconnect all power to the electrical components of the stove. Never try to repair or replace any part of the stove unless instructions for doing so are given in th...
Page 18 - PARTS LIST
18 USSC 13 5 11 10 1 10 12 10 6 12 7 8 2 4 3 9 9 9 Parts Diagram/List models 5500 & 5500XL 6 3 4 1 5 7 2 8 9 Item Part No. Title Qty. 1 25490 Door Weldment 1 2 891166 Ceramic Glass 1 3 891185 Glass Retainer, Top 1 4 891186 Glass Retainer, Bottom 1 5 891160 Handle, Door 1 6 891168 Latch, Door 1 7...
Page 19 - WIRING DIAGRAM
USSC 19 Parts List model 5500 & 5500XL Item Part No. Title Qty. 1 86624 Burnpot Assembly 1 2 86625 Housing Assy, Burnpot 1 3 86628 Weldment, Exhaust Duct 1 4 86633 Weldment, Igniter Tube 1 5 80481 Igniter Cartridge 1 6 25506 Weldment, Door Hinge 1 7 69512 Door Assembly 1 8 69518 Hopper Assembly ...
Page 20 - THE PART DESCRIPTION; HOW TO ORDER REPAIR PARTS; United States Stove Company
20 USSC THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLESERVICE FROM YOUR KING OR ASHLEY, AND ENABLE YOU TOORDER REPAIR PARTS CORRECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFER-ENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBERWHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER. WHEN...