US Stove Company 6041TP - Manual

US Stove Company 6041TP

US Stove Company 6041TP – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – NOTE: YOUR UNIT MUST BE INSTALLED BY A; Perform initial burn outside if possible; SPECIFICATIONS; United States Stove Company; Heat Input; Heating Capacity
  • Page 3 – Assembly; 041TP PEDESTAL TRIM ASSEMBLY
  • Page 4 – Facade Trim; DISCONNECT THE POWER CORD BEFORE SERVICING THIS Heater
  • Page 5 – COMPONENT LOCATION
  • Page 6 – SAFETY STEPS; inspection guidelines before installing the product.; American Harvest; BURNING SOLID FUELS
  • Page 7 – FLOOR PROTECTION; INSTALLATION REQUIREMENTS; SHELLED CORN; DO NOT PLACE SUCH FUELS WITHIN THE SPACE HEATER’S
  • Page 8 – Parallel; BACK WALL; Corner Installation
  • Page 9 – CLEARANCES TO COMBUSTIBLES 6041I
  • Page 10 – GUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN; DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM; VENT TERMINATION CLEARANCES:
  • Page 11 – 0 DEGREE BEND TERMINATION; Wind Hood; DESIGN GUIDELINES FOR OUTSIDE COMBUSTION AIR CONNECTION
  • Page 12 – MOBILE HOME INSTALLATION REQUIREMENTS; REQUIREMENTS ARE MANDATORY FOR INSTALLATION IN A MOBILE HOME:; WARNING; DO NOT INSTALL IN SLEEPING ROOM; CAUTION; ROOF MUST BE MAINTAINED.; Check with your local building official as other codes may apply.; INSTALLATION CONFIGURATIONS
  • Page 13 – Dimensional tolerance
  • Page 14 – THROUGH THE WALL, VERTICAL PIPE INSTALLATION; A MINIMUM OF 3 VERTICAL
  • Page 15 – DESIGN GUIDELINES FOR 6041I INSERT INSTALLATION; INSTALLATION AS A BUILT-IN FIREPLACE; Alternative Exhaust Venting
  • Page 16 – INSTALLATION INTO A MASONRY FIREPLACE
  • Page 17 – Heater; REMOVAL OF BROKEN OR DAMAGED CERAMIC GLASS; Do not operate unit with broken glass.; CLEANING THE GLASS; GLASS MAINTENANCE, REMOVAL AND REPLACEMENT; GLASS CLIPS
  • Page 18 – UNDERSTANDING THE CONTROL BOARD; CONTROL PANEL; LIGHTING INSTRUCTIONS; DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE.
  • Page 19 – Using Wood Pellets: Ensure your display shows a “Pr” for pellets.
  • Page 20 – Soot and Flyash - Formation and Need for Removal; Daily Maintenance; MAINTENANCE INSTRUCTIONS; SPECIAL CLEANING/OPERATIONAL
  • Page 21 – These automatic safety features must not be bypassed; Weekly Maintenance; AUTOMATIC SAFETY FEATURES; Power Outage; Overheating; Hopper Safety Switch and Pressure Switch; FUEL ADDITIVE
  • Page 22 – CONTROL BOARD FUNCTIONS
  • Page 23 – ERROR CODES and DISPLAY INDICATORS
  • Page 24 – TROUBLE SHOOTING; All other work should be done by a trained technician.
  • Page 25 – WIRING DIAGRAM; WIRING SCHEMATIC
  • Page 29 – Parts List
  • Page 30 – 041HF Parts Diagram & List
  • Page 31 – NOTE
  • Page 32 – enable you to order repair parts correctly.
Loading the manual

USSC

1

851772 rev

A

C

S

S

U

C O M PA N Y

UN

ITE

D STATES STOV

E

United States Stove Company

• 227 Industrial Park Road, P.O. Box 151 • South Pittsburg, TN 37380 • www.usstove.com

Safety Tested to ASTM-E 1509, (UM) 84-HUD

American Harvest

Safety Notice: If this heater is not properly installed, a

house fire may result

.

For your safety, follow the installation directions. Contact local building or fire of

-

ficials about restrictions and installation requirements peculiar to your area.

Do

Not Plug

this appliance into an electrical outlet before reading and understanding

all operations and

always unplug

the unit before attempting any work or main

-

tenance. Do not connect this heater to any chimney flue already serving another

appliance. Carefully observe and maintain all

clearances to combustibles.

A note about fuel:

Use only

dried shelled corn

with a moisture content of 14%

or less

(11 to 12% provides the best results);

any pellet fuel used should

have an ash content of 1% or less. If not, efficiency will suffer. This heater has

successfully burned pellets with a 2-1/2% ash content, though less ash is preferred

and more efficient.
Your American Harvest Multi-Fuel Heater operates on a negative pressure. There

-

fore,

all venting connections (elbows, T-pipe) must be sealed and airtight.

i

Use Hi-Temp silicone at each joint or connection.

READ THIS ENTIRE MANUAL

, THOROUGHLY, BEFORE ATTEMPTING TO INSTALL AND/

OR BURN YOUR NEW AMERICAN HARVEST *MULTI-FUEL HEATER. FAILURE TO FOLLOW

THESE INSTRUCTIONS MAY RESULT IN

PROPERTY DAMAGE, BODILY INJURIES OR

EVEN DEATH

.

*This heater is capable of burning wood, biomass pellets and a wide variety of grains,

including corn, soybeans, cherry and olive pits, and all larger seeds.

SAVE THESE INSTRUCTIONS

UNITED STATES STOVE COMPANY GRANTS NO WARRANTY, IMPLIED OR STATED,

FOR THE INSTALLATION OR MAINTENANCE OF THE HEATER AND ASSUMES NO

RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).

Tested &

Listed By

Portland

Oregon USA

Omni-Test Laboratories, Inc.

US

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - NOTE: YOUR UNIT MUST BE INSTALLED BY A; Perform initial burn outside if possible; SPECIFICATIONS; United States Stove Company; Heat Input; Heating Capacity

2 USSC NOTE: YOUR UNIT MUST BE INSTALLED BY A QUALIFIED INSTALLER, such as an NFI (National Fireplace Institute) Certified Specialist You’ve purchased one of America’s Finest Multi-fuel Burning Heaters. By heating with fuels such as corn and pellets, you’re helping CONSERVE AMERICA’S ENERGY! We stro...

Page 3 - Assembly; 041TP PEDESTAL TRIM ASSEMBLY

USSC 3 1 1 2 2 A A B B Assembly 1. Unpack unit and make sure all components are included; (4) Legs, and all hardware for installation. 2. Fold the corner padding from the carton and lay it on the floor behind the unit. This is used to hold the heater up off the floor to install the legs. Gently tilt...

Page 4 - Facade Trim; DISCONNECT THE POWER CORD BEFORE SERVICING THIS Heater

4 USSC (a) (a) (c) (h) (f) (g) (b) (e) 6041I ASSEMBLY (i) (j) For the following assemblies, we suggest locating the unit near it’s desired location. Depending on installation, you may want to connect the exhaust venting before installing the facade parts. Assembly - Facade (Surround) Remove contents...

Other US Stove Company Models

All US Stove Company Other