Tripp Lite IBAR 12 - Manual

Tripp Lite IBAR 12

Tripp Lite IBAR 12 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – Features; Circuit Breaker
  • Page 3 – Specifications
  • Page 5 – Barras de Contacto para Montaje en; Instalacion en Bastidor o Rack
  • Page 6 – Characteristicas
  • Page 7 – Bancos de Filtros Aislados y Circuito en Cascada; continua; Especificaciones
  • Page 9 – Garantía Limitada para la Vida Útil del Equipo
  • Page 11 – Locs D'alimentation et Limiteurs de; Conçu pour occuper un espace standard dans un bâti de 19 po (48 cm); Installation Sur Bati
  • Page 12 – Caracteristiques; Disjoncteur
  • Page 13 – suite
  • Page 15 – Garantie Limitee a Vie; Assurance Ultime á Vie
Loading the manual

Owner’s Manual

Rackmount Power Strips and Isobar

®

Rackmount Surge Suppressors/

Line-Noise Filters

Designed to Occupy One Standard 19 in. Rack Space

IMPORTANT SAFETY INSTRUCTIONS. This manual contains information concerning the proper installation
and use of Tripp Lite’s Rackmount Power Strips and Isobar Surge Suppressors. SAVE THESE INSTRUCTIONS.

(IBAR12, IBAR12ULTRA, RS-1215, RS-1215-RA, RS-1215-HG, RS-0615-R,
RS-0615-F, DRS-1215): DO NOT exceed the MAXIMUM LOAD of 15 amps that
can be drawn from each AC outlet. DO NOT exceed the MAXIMUM LOAD of
15 amps that can be drawn from all the outlets combined.

(IBAR12/20ULTRA, IBAR12-20T, RS-1215-20): DO NOT exceed the MAXIMUM LOAD of 15
amps that can be drawn from each AC outlet located on the front of the IBAR12/20ULTRA
and IBAR12-20T. DO NOT exceed the MAXIMUM LOAD of 20 amps that can be drawn from
each AC outlet on the RS-1215-20, or each AC outlet located on the rear of the
IBAR12/20ULTRA and IBAR12-20T. DO NOT exceed the MAXIMUM LOAD of 20 amps that
can be drawn from all the outlets combined.

Español: p. 5 • Français: p. 11

Rackmount Installation

To Mount Unit in Rack:

Put four user-supplied rackmount

screws (A) through the unit’s mounting ears (B) and into
the rack rails as shown. The user must determine the fitness
of the rackmount screws to hold the unit in the rack before
installation.

Wallmount/Under Counter Installation

1. Detach Mounting Ears:

Unscrew the screws (A) holding

the unit’s mounting ears (B) to the sides of the unit.

2. Reorient Mounting Ears:

Use the screws from Step 1 (A)

to reattach the mounting ears (B) to the unit as shown.
Use only the manufacturer-supplied screws or their
equivalent (#6-32, ¼" flat head) to reattach the mounting
ears. The screws should be put through diagonally
opposite holes on the ear.

3. Mount Unit on Surface:

Put four user-supplied screws

(C) or similar mounting hardware through the unit’s
mounting ears (B) and into the mounting surface as
shown. The user must determine the fitness of the user-
supplied mounting hardware to support the unit before
mounting.

A

B

Step 1

Steps 2 & 3

200112060 Isobar RM Metal Owner’s Manual 93-2028.qxd 1/3/02 2:48 PM Page 1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Features; Circuit Breaker

2 Features Circuit Breaker (All Models) If the current draw of the equipment connected to your model exceeds your model’s circuit breaker rating(15 or 20 amps; see Specifications) for longer than a few seconds, the circuit breaker will trip to preventany possible damage. When the circuit breaker tri...

Page 3 - Specifications

3 Specifications IBAR12 IBAR12ULTRA IBAR12/20ULTRA AC Energy Absorption (joules): 750 1200 1200 Surge Suppression (amp spikes)*: 60,000 96,000 96,000 UL 1449 Let-Through Rating: 400V 330V 330V HF Noise Suppression (@ 1 MHz) Filter Bank #1: 40 dB 40 dB 80 dB Filter Bank #2: 80 dB 80 dB — AC Receptacl...

Page 5 - Barras de Contacto para Montaje en; Instalacion en Bastidor o Rack

5 Manual de Operación Barras de Contacto para Montaje en Bastidor y Supresores de Sobretensiones de Isobaras para Montaje en Bastidor Isobar ® /Filtros de Ruido en Línea Diseñados para ocupar un espacio estándar de bastidor de 19 pulgadas INSTRUCCIONES DE SEGURIDAD IMPORTANTES. Este manual contiene ...