TABULAR DATA SHEET

Outdoor Split System Heat Pump 1.5 Thru 5 Tons

MODELS: THJF18* THRU 60

14.5 SEER – R-410A, 1 PHASE

All dimensions are in inches. They are subject to change without notice.
Certified dimensions will be provided upon request.

Physical and Electrical Data

MODEL

THJF18

S41S3

THJF24

S41S3

THJF30

S41S3

THJF36

S41S3

THJF42

S41S3

THJF48

S41S3

THJF60

S41S3

Unit Supply Voltage

208-230V, 1



60Hz

Normal Voltage Range

1

187 to 252

Minimum Circuit Ampacity

11.9

17.6

17.3

23.7

26.1

28.8

35.3

Max. Overcurrent Device Amps

2

20

30

30

40

45

50

60

Min. Overcurrent Device Amps

3

15

20

20

25

30

30

40

Compressor Type

Scroll

Scroll

Scroll

Scroll

Scroll

Scroll

2-Stage Scroll

Compressor
Amps

Rated Load

9.0

13.4

12.8

17.9

19.8

28.8

35.3

Locked Rotor

48.0

58.3

64.0

96.7

115.0

115.0

118.0

Crankcase Heater

No

No

No

No

No

No

No

Factory External Discharge Muffler

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Factory External Check Valve

No

No

No

No

No

No

No

HS Kit Required with TXV

4

No

No

No

No

No

No

No

Fan Motor Amps

Rated Load

0.7

0.8

1.3

1.3

1.3

1.3

1.3

Fan Diameter Inches

24

22

24

24

24

24

24

Fan Motor

Rated HP

1/10

1/8

1/4

1/4

1/4

1/4

1/4

Nominal RPM

825

1075

850

850

850

850

850

Nominal CFM

2000

2000

3900

3900

3900

3800

3800

Coil

Face Area Sq. Ft.

15.72

19.17

23.58

23.58

23.58

23.58

23.58

Rows Deep

1

1

1

1

1

2

2

Fin / Inches

22

22

22

22

22

18

18

Liquid Line Set OD (Field Installed)

3/8

3/8

3/8

3/8

3/8

3/8

3/8

Vapor Line Set OD (Field Installed)

3/4

3/4

3/4

3/4

7/8

7/8

1-1/8

Unit Charge (Lbs. - Oz.)

5

6 - 15

7 - 14

9 - 14

10 - 9

10 - 14

14 - 2

14 - 2

Charge Per Foot, Oz.

0.62

0.62

0.62

0.62

0.67

0.67

0.75

Operating Weight Lbs.

145

145

176

193

198

248

290

1. Rated in accordance with ANSI/AHRI Standard 110-2002, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.
5. The Unit Charge is correct for the outdoor unit, matched indoor coil, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet,

add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.

B

C

A

Unit

Model

Dimensions

(Inches)

Refrigerant Connection

Service Valve Size

A

1

1. Including Fan Guard.

B

C

Liquid

Vapor

18

28

34

34

3/8”

3/4”

24

40

29

29

30

40

34

34

36

40

34

34

42

40

34

34

7/8”

48

40

34

34

60

40

34

34

MAC-222
ECN 5287-MA 121005