Teledyne MX300-I - Manual

Teledyne MX300-I

Teledyne MX300-I – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
Page: / 48

Table of Contents:

  • Page 2 – ii; Copyright © 2002 Teledyne Analytical Instruments; FCC Statement; Warranty
  • Page 3 – About This Manual; How To Use This Manual
  • Page 4 – Safety Messages; CAUTION
  • Page 5 – Table of Contents; Applicable Standards
  • Page 7 – vii; List of Figures
  • Page 8 – viii; List of Tables; Table 2-1: Oxygen Reading Error in a Mixture of Anesthetic Gas . 29
  • Page 9 – Introduction; Teledyne Analytical Instruments MX300-I Oxygen Monitor with
  • Page 12 – Theory of Operation
  • Page 13 – The MX300-I uses the Teledyne Class R17MED disposable oxygen
  • Page 14 – The oxygen level is calculated and then displayed on the liquid
  • Page 15 – Operation; Note: Upon receipt, INSPECT THE ENTIRE UNIT FOR
  • Page 16 – Sensor Installation or Replacement; Note: The R17MED oxygen sensor must be installed before the
  • Page 17 – Figure 2-2: Sensor Cable Connection to Monitor
  • Page 18 – Note: The door latch is a tight fit onto the battery cover. Use a; Figure 2-5: Brass Insert for Universal Mounting Clamp
  • Page 19 – Note: Three “AA” alkaline batteries must be installed in the unit
  • Page 20 – Note: When batteries are first installed or power is lost for any
  • Page 21 – available from Teledyne for use with the R17MED sensor
  • Page 22 – Note: Never calibrate the unit in humidified gas, as water vapor
  • Page 23 – Note: When the alarm is in the OFF condition (set point above
  • Page 24 – To activate the digital output:
  • Page 25 – Note: Prior to use, always test the batteries and alarms (if
  • Page 27 – The R17MED oxygen sensor adjusts for ambient temperature
  • Page 28 – The MX300-I instrument should be used to measure the oxygen; When using the R17MED sensor in the presence of anesthetic gases
  • Page 29 – Table 2-1: Oxygen Reading Error in a Mixture of Anesthetic Gas; Gas or Vapor Level; * Errors are approximate and may vary based on exposure times and
  • Page 30 – Do’s and Don’ts
  • Page 32 – Place the unit itself in a water vapor-saturated environment.
  • Page 33 – Service Manual; General Service Information; The Teledyne Model MX300-I Portable Oxygen Monitor is; Overall Maintenance; The MX300-I requires very little maintenance, other than; Battery Maintenance; Test batteries regularly. (replace immediately when all 5 bars
  • Page 34 – Sensor Maintenance; DON’T
  • Page 36 – The reading will rise proportionally less for smaller pressures.
  • Page 37 – Note: The MSDS on this material is located in the Appendix. It is; Symptom
  • Page 40 – Note: In the event that none of these procedures produce desired
  • Page 41 – Other Problems with the Instrument; Most other problems arise from either mechanical damage from the
  • Page 42 – Return Authorization for Service; For any service beyond sensor and battery replacement, the; TELEDYNE Analytical Instruments
  • Page 43 – Appendix; 0% in less than 8 seconds at 25 °C
  • Page 44 – A.2 Spare Parts List; QTY PART; A.3 Optional Accessories
  • Page 45 – Note: Orders for replacement parts should include the part
  • Page 47 – Index
Loading the manual

Portable Oxygen Monitor

Teledyne

Analytical

Instruments

i

OPERATING & SERVICE INSTRUCTIONS FOR

MX300-I

P

ORTABLE

O

XYGEN

M

ONITOR




0086

TYPE B EQUIPMENT:

Equipment providing a particular degree
of protection against electric shock,
particularly regarding—

• Allowable LEAKAGE CURRENT

• Reliability of the protective earth

connection (if present).

P/N M75707

REV 1

ECO # 04-0088

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - ii; Copyright © 2002 Teledyne Analytical Instruments; FCC Statement; Warranty

MX300-I Teledyne Analytical Instruments ii Copyright © 2002 Teledyne Analytical Instruments All Rights Reserved No part of this manual may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any other language or computer language in whole or in part, in any for...

Page 3 - About This Manual; How To Use This Manual

Portable Oxygen Monitor Teledyne Analytical Instruments iii About This Manual The MX300-I Operator's Manual provides both introductory and detailed information for configuring and operating these instruments. The manual takes you from the time you unpack the instrument until you complete the first g...

Page 4 - Safety Messages; CAUTION

MX300-I Teledyne Analytical Instruments iv Safety Messages Your safety and the safety of others are very important. Please carefully read the following safety messages. Safety message are indented to alert the user of potential hazards. Each safety message is associated with a safety alert symbol. T...