Page 3 - Foreword; Return Authorization Number; Contact Information
Foreword This instruction manual is designed to help you gain a thorough understanding of theoperation of the equipment. Teledyne Isco recommends that you read this manualcompletely before placing the equipment in service. Although Teledyne Isco designs reliability into all equipment, there is alway...
Page 5 - 102 Wireless Communication Module; Table of Contents
iii 2102 Wireless Communication Module Table of Contents Section 1 Quick Start Guide 1.1 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11.2 Wireless Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 6 - List of Figures
2102 Wireless Communication ModuleTable of Contents iv List of Figures 1-1 2102 Components - Top View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-21-2 2102 Components - Bottom View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3...
Page 7 - Section 1 Quick Start Guide
1-1 2102 Wireless Communication Module Section 1 Quick Start Guide 1.1 Getting Started This Quick Start Guide provides a basic introduction to the 2102Wireless Communication Module. In this section we discuss: • Identifying key components of the Wireless Module • Module connectors and caps • System ...
Page 8 - Components; Table 1-1 Wireless Module Components - Top View; Description
2102 Wireless Communication ModuleSection 1 Quick Start Guide 1-2 1.2 Wireless Module 1.2.1 Identifying Module Components Figures 1-1 and 1-2 identify key components of the 2102. Figure 1-1 2102 Components - Top View 4 2 1 3 5 Table 1-1 Wireless Module Components - Top View Item No. Description 1 Co...
Page 9 - Connectors; CAUTION; PUSH ON; PULL OFF; Note; Table 1-2 Wireless Module Components - Bottom View
2102 Wireless Communication Module Section 1 Quick Start Guide 1-3 Figure 1-2 2102 Components - Bottom View 1.2.2 Communication Connectors When a communication connector is not in use, the con-nector must always be capped (Figures 1-3 and 1-5). The cap will seal the connector to prevent corrosion, p...
Page 11 - System Connections; Connections
2102 Wireless Communication Module Section 1 Quick Start Guide 1-5 1.3 System Connections Connections for the 2102 Wireless modules are described as a b a s e m o d u l e a n d r e m o t e m o d ul e. T h e ba s e w i r e l e s s m o du l e allows a personal computer running Flowlink for Windows (v4...
Page 12 - Base unit cable configurations
2102 Wireless Communication ModuleSection 1 Quick Start Guide 1-6 Figure 1-7 Connections RS-232 Serial Ports COM1 or COM2 Power Option 1 12 VDC Cigarette Adapter Power Option 2 AC Adapter Power Option 3 2191 Battery Module 2191 21xx 2102 2102 Communication Cable 2191 2102 4200 Interrogator Port 4100...
Page 13 - Section 2 Introduction; Product Description; Overview
2-1 2102 Wireless Communication Module Section 2 Introduction 2.1 Product Description The 2102 Wireless Communication Module is part of TeledyneTeledyne Isco’s 2100 Series system. The 2100 Series system mea-sures parameters of open channel flow streams. The 2100 Series system is designed to be modul...
Page 14 - 102 Wireless Module Features; and Indicators; LED Operation for the Remote Unit:
2102 Wireless Communication ModuleSection 2 Introduction 2-2 2102 Wireless Module Features • No cell phone hassles • no monthly fees • no FCC licensing • no exposed antennas • Long range • Long battery life on two 6-volt alkaline batteries 2.2 Applications Typical applications for the 2102 include: ...
Page 16 - Specifications; Name; Table 2-2 Technical Specifications – 2102 Module
2102 Wireless Communication ModuleSection 2 Introduction 2-4 2.4 Technical Specifications This section lists technical information about the 2102 Module. • Table 2-2 lists the technical specifications of the 2102. • Table 2-3 lists the technical specifications of the Spread Spectrum Radio. • Table 2...
Page 17 - Table 2-3 Technical Specifications – Spread Spectrum Radio
2102 Wireless Communication Module Section 2 Introduction 2-5 Table 2-3 Technical Specifications – Spread Spectrum Radio Frequency 902 to 928 MHz Transmitter Output Power Typical Range line of sight from inside manhole Modulation, GFSK Occupied bandwidth 1 W 0.5 miles (0.8 km) 100 feet (30 m) 120 kB...
Page 18 - Table 2-5 Wireless Module Connector Pins; Pin
2102 Wireless Communication ModuleSection 2 Introduction 2-6 Figure 2-2 2102 Connector Pins A B C D E F G Communications Port (upper connector shown) Table 2-5 Wireless Module Connector Pins Pin Name Description A LONA Neuron differential transceiver Data A B LONB Neuron differential transceiver Dat...
Page 19 - Section 3 Preparation and Installation; Instructions; If there is any evidence that any items may have been; Installation; WARNING; The installation and use of this product may subject you
3-1 2102 Wireless Communication Module Section 3 Preparation and Installation 3.1 Unpacking Instructions When the Wireless Module arrives, inspect the outside packingfor any damage. Then carefully inspect the contents for damage.If there is damage, contact the delivery company and TeledyneIsco (or i...
Page 25 - Section 4 Programming; Flowlink Connections
4-1 2102 Wireless Communication Module Section 4 Programming 4.1 Section Overview This section describes how to set up the operation of a 2100Parameter Module using Teledyne Teledyne Isco’s Flowlink forWindows software. Note The 2100 System requires Flowlink 4.1 or later. Earlier ver-sions do not su...
Page 26 - Remote Unit Configuration
2102 Wireless Communication ModuleSection 4 Programming 4-2 Figure 4-1 Connections RS-232 Serial Ports COM1 or COM2 Power Option 1 12 VDC Cigarette Adapter Power Option 2 AC Adapter Power Option 3 2191 Battery Module 2191 21xx 2102 2102 Communication Cable 2191 2102 4200 Interrogator Port 4100/4200/...
Page 27 - Table 4-1 Base Module Connect Cables; Part Number
2102 Wireless Communication Module Section 4 Programming 4-3 4.2.1 Communication Resolution (2100 only) During the connection process, Flowlink checks the stability oft h e s i t e ’s co m m un i ca t i o n s. I f c o m m u ni c a t i o n i s f o u nd t o b eun stable, Flowlink presents the Commu ni...
Page 29 - Section 5 Maintenance
5-1 2102 Wireless Communication Module Section 5 Maintenance 5.1 Maintenance Overview T h e 2 1 0 0 S e r i e s s y s t e m i s d e s i g n e d t o p e r f o r m r e l i a b l y i nadverse conditions with a minimal amount of routine servicerequirements. M a i n t e n an ce i nt e r v a l s a re a f ...
Page 31 - Appendix A Replacement Parts; A.1 Replacement Parts
A-1 2102 Wireless Communication Module Appendix A Replacement Parts A.1 Replacement Parts Diagrams and Listings Replacement parts are called out in Figure A-1. Reference thecall-out in the adjacent table to determine the part number forthe item. Replacement parts can be purchased by contacting Teled...
Page 33 - Table A-1 Replacement Parts Listing –
2102 Wireless Communication Module Appendix A Replacement Parts A-3 Table A-1 Replacement Parts Listing – 2102 Wireless Communication Module Item No. Fig. A-1 Part Number Description 1 231310106 SCREW, SELF TAPPING, #4 2 602003087 CLAMP SPACER 3 602004012 CAP ASSEMBLY, MALE CONNECTOR 4 202100669 O R...
Page 35 - ᳝↦᳝ᆇ⠽䋼ܗユ
Warranty Table Hazmat 2100 Nodes 60-2003-550 Rev. ℶ❐₼㦘㹡㦘⹂䓸德㒥⏒侯䤓⚜䱿♙⚺摞 Name and amount of Hazardous Substances or Elements in the product ᳝↦᳝ᆇ⠽䋼ܗ㋴ Hazardous Substances or Elements 捷ↅ⚜䱿 Component Name 䪙 (Pb) ∲ (Hg) 䬝 (Cd) ݁Ӌ䫀 (Cr(VI)) ⒈㘨㣃 (PBB) ⒈Ѡ㘨㣃 (PBDE) 兎恾㨎 Circuit Boards X O O O O O ℶ❐₼㦘㹡㦘⹂䓸德㒥⏒侯...
Page 37 - Return Authorization
Teledyne Isco One Year Limited Factory Service Warranty * Teledyne Isco warrants covered products against failure due to faulty parts or workmanship for a period of one year (365 days) from their shipping date, or from the date of installation by an authorized Teledyne Isco Service Engineer, as may ...