Page 2 - Summary; INSTRUCTIONS FOR THE INSTALLER: these are for the
Summary 1 INSTRUCTIONS FOR SAFE AND PROPER USE________________ 4 2 POSITIONING OF THE HOB ________________________________ 6 3 GAS CONNECTION ______________________________________ 12 4 ADJUSTMENT TO DIFFERENT TYPES OF GAS _______________ 14 5 FINAL OPERATIONS _____________________________________ 1...
Page 3 - Introduction; INSTRUCTIONS FOR SAFE AND PROPER USE
Introduction 1 INSTRUCTIONS FOR SAFE AND PROPER USE THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE HOB. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE USING THE HOB. ALSO ...
Page 5 - Instructions for the installer; POSITIONING OF THE HOB; be carried out by a competent tradesman.
Instructions for the installer 6 2 POSITIONING OF THE HOB The following operation requires building and/or carpentry work so must be carried out by a competent tradesman. Installation can be carried out on various materials such as masonry, metal, solid wood or plastic laminated wood, as long as the...
Page 6 - Attachment to support structure, flush-mounting model; Apply a layer of “waterproof primer” to the milled surface.
Instructions for the installer 2.2 Attachment to support structure, flush-mounting model Create an opening with the dimensions shown in the figure in the work surface, observing a minimum distance of 50 mm from the rear edge. 1) The lower part of the protective cover must be fully accessible when th...
Page 8 - Clearance above and around domestic appliances
Instructions for the installer 2.3 Clearance above and around domestic appliances Extract from AS5601 REQUIREMENTS 1 Overhead clearances – (Measurement A) Range hoods and exhaust fans shall be installed in accordance with the manufacturer’s instructions. However, in no case shall the clearance betwe...
Page 9 - 0 mm or more, or the horizontal surface shall be above the; Room ventilation
Instructions for the installer 10 2 Side clearances – (Measurements B & C) Where B, measured from the periphery of the nearest burner to any vertical combustible surface , is less than 200 mm, the surface shall be protected in accordance with Clause 5.12.1.2 to a height C of not less than 150 mm...
Page 10 - Discharge of combustion products
Instructions for the installer Discharge of combustion products Discharge of combustion products must be guaranteed by means of hoods connected to a natural draught flue with certain efficiency, or by means of forced aspiration. An efficient aspiration system requires careful planning by a specialis...
Page 11 - GAS CONNECTION; annealed copper pipe or
Instructions for the installer 12 3 GAS CONNECTION This appliance is suitable for installation with Natural Gas or LPG (propane). Refer to page 12 for the relevant burner pressure and appropriate injector sizes. When the appliance is to be connected to Natural Gas then the pressure regulator supplie...
Page 12 - Electrical connection; Do not use reducers, adapters or shunts.
Instructions for the installer 3.1 Electrical connection Make sure that the voltage and capacity of the power supply cable conform to the data shown on the plate located under the protective cover. Do not remove this plate for any reason. The power supply cable plug and the wall socket must be of th...
Page 13 - ADJUSTMENT TO DIFFERENT TYPES OF GAS; Replacement of nozzles on the hob; Replace the burners in the correct position.
Instructions for the installer 14 4 ADJUSTMENT TO DIFFERENT TYPES OF GAS Before performing any cleaning or maintenance work, unplug the appliance from the mains. The hob of the cooker is adjusted for use with either natural gas at a pressure of 1.0 kPa. If used with other types of gas, you have to r...
Page 14 - Burner and nozzle characteristics table; Arrangement of burners on cooking hob; Auxiliary
Instructions for the installer 4.2 Burner and nozzle characteristics table Burner ULPG – 2.75 kPa Nominal gas Consumption (MJ/h) Injector (mm) Auxiliary (1) 3.9 0.54 Semi rapid (2) 6.3 0.68 Ultra Rapid (3) 13.5 1.00 Burner NG – 1.0 kPa Nominal gas Consumption (MJ/h) Injector (mm) Auxiliary (1) 3.9 0...
Page 15 - FINAL OPERATIONS; Regulation of minimum for town gas and natural gas
Instructions for the installer 16 5 FINAL OPERATIONS After carrying out the above adjustments, remount in reverse order to the instructions given in paragraph “3.1 Replacement of nozzles on the hob”. After having regulated the device with gas other than the one tested, replace the label located on t...
Page 16 - Instructions for the user; USING THE HOB; Ignition of the burners; the high flame symbol
Instructions for the user 6 USING THE HOB 6.1 Ignition of the burners Before turning on the burners, make sure that the flame-spreader crowns and respective caps are properly fitted in their housings. Ensure the flame-spreader holes A are aligned with the ignition plugs and the thermocouples. Pansta...
Page 17 - Practical advice for using the burners
Instructions for the user 18 6.2 Practical advice for using the burners For better use of the burners and lower gas consumption, use covered cooking receptacles that have a flat, smooth bottom and are proportional in size to the burner to prevent the flame from licking the sides (see paragraph “6.3 ...
Page 18 - CLEANING AND MAINTENANCE; Before any intervention, disconnect the appliance from the mains.; Cleaning the stainless steel; Routine daily cleaning; Cleaning of cooking hob components
Instructions for the user 7 CLEANING AND MAINTENANCE Before any intervention, disconnect the appliance from the mains. 7.1 Cleaning the stainless steel To keep stainless steel in good condition it should be cleaned regularly after use. Let it cool first. 7.1.1 Routine daily cleaning To clean and pre...
Page 19 - Preventive maintenance; Gas connection: the gas connection must be checked periodically.; PROBLEMS AND CAUSES; PROBLEM
Instructions for the user 20 7.3 Preventive maintenance This appliance does not need any special maintenance. However, a few simple operations have to be carried out periodically to prevent malfunctioning: Burners: the burners must be cleaned periodically to ensure correct combustion; make sure that...