  • Page 3 – Installation in vertical pipes with free outlet
  • Page 5 – With earthing electrodes
  • Page 6 – AWWA; mating flanges; Torque calculations
  • Page 8 – into account during flowmeter design.; Manufacturer’s design
  • Page 9 – INSTRUCTIONS; SITRANS F M MAGFLO; DEUTSCH; Siemens Flow Instruments SITRANS F M MAGFLO; Einführung; Abmessungen
  • Page 11 – Einbau an höchster Stelle des Rohrsystems
  • Page 13 – Mit Erdungselektroden
  • Page 14 – und den zugehörigen Flanschen verwendet
  • Page 15 – Verschraubung
  • Page 16 – werden bei der Auslegung des Messers nicht berücksichtigt.
  • Page 17 – FRANÇAIS; Le débitmètre à induction magnétique SITRANS FM MAGFLO; Présentation; Dimensions
  • Page 19 – le montage sur tubes verticaux à sortie libre.
  • Page 20 – , on obtient la courbe de
  • Page 21 – Avec les électrodes de terre
  • Page 22 – on inégale; Calculs du couple; débitmètre et les brides respectives
  • Page 24 – sont pas prises en compte pour la conception du débitmètre.
  • Page 25 – DANSK; Indledning; Mål
  • Page 27 – Derfor bør man undgå:
  • Page 28 – som vist på den
  • Page 29 – Med jordingselektroder
  • Page 30 – Moment beregning; hårdhed 75 shore A
  • Page 32 – betragtning ved udformning af flowmåleren.; Producentens udsagn
Loading the manual

INSTRUCTIONS

SITRANS F M MAGFLO

Electromagnetic flowmeter
type MAG 5100 W

ENGLISH

083R9166

SFIDK.PI.026.V1.52

Siemens Flow Instruments SITRANS F M MAGFLO

electromagnetic flowmeters consist of a

sensor and a transmitter. These instructions only describe the sensor installation. For further
information on the transmitter installation, please refer to the SITRANS F M MAGFLO

handbook.

Introduction

MAG 5100 W, compact/separate

Dimensions and
weight

mm

inch

mm

inch

mm

inch

mm

inch

mm

inch

mm

inch

mm

inch

25

1"

187

7.4

N/A

N/A

N/A

N/A

200

7.9

200

7.9

N/A

N/A

40

1½”

197

7.8

N/A

N/A

N/A

N/A

200

7.9

200

7.9

N/A

N/A

50

2"

188

7.4

N/A

N/A

200

7.9

N/A

N/A

200

7.9

N/A

N/A

65

2½”

194

7.6

N/A

N/A

200

7.9

N/A

N/A

200

7.9

N/A

N/A

80

3"

200

7.9

N/A

N/A

200

7.9

N/A

N/A

200

7.9

N/A

N/A

100

4"

207

8.1

N/A

N/A

250

9.8

N/A

N/A

250

9.8

N/A

N/A

125

5"

217

8.5

N/A

N/A

250

9.8

N/A

N/A

250

9.8

N/A

N/A

150

6"

232

9.1

N/A

N/A

300

11.8

N/A

N/A

300

11.8

N/A

N/A

200

8"

257

10.1

350

13.8

350

13.8

N/A

N/A

350

13.8

N/A

N/A

250

10"

284

11.2

450

17.7

450

17.7

N/A

N/A

450

17.7

N/A

N/A

300

12"

310

12.2

500

19.7

500

19.7

N/A

N/A

500

19.7

N/A

N/A

350

14"

362

14.3

550

21.7

550

21.7

N/A

N/A

550

21.7

N/A

N/A

400

16"

387

15.2

600

23.6

600

23.6

N/A

N/A

600

23.6

N/A

N/A

450

18"

418

16.5

600

23.6

600

23.6

N/A

N/A

600

23.6

N/A

N/A

500

20"

443

17.4

625

24.6

625

24.6

N/A

N/A

680

26.8

N/A

N/A

600

24"

494

19.4

750

29.5

750

29.5

N/A

N/A

820

32.3

N/A

N/A

700

28"

544

21.4

875

34.4

875

34.4

N/A

N/A

N/A

N/A

875

34.4

750

30"

571

22.5

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

937

36.9

800

32"

606

23.9

1000

39.4

1000

39.4

N/A

N/A

N/A

N/A

1000

39.4

900

36"

653

25.7

1125

44.3

1125

44.3

N/A

N/A

N/A

N/A

1125

44.3

1000 40"

704

27.7

1250

49.2

1250

49.2

N/A

N/A

N/A

N/A

1250

49.2

42"

704

27.7

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

1250

49.2

1100 44"

755

29.7

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

1375

54.1

1200 48"

810

31.9

1500

59.1

1500

59.1

N/A

N/A

N/A

N/A

1500

59.1

AWWA

Nominal

size

A

L

PN 10

PN 16

PN 40

Class 150

Dimensions

s

Order no.: FDK:521H1190

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Installation in vertical pipes with free outlet

3 SITRANS F M MAGFLO      Electromagnetic flowmeter type MAG 5100 W Installation, general Reading and operating the flowmeter is possi-ble under almost any installation conditionsbecause the display can be oriented in relationto the sensor. To ensure optimum flow mea-surement attention should b...

Page 5 - With earthing electrodes

5 SITRANS F M MAGFLO      Electromagnetic flowmeter type MAG 5100 W Potential equalisation Potential equalisation is carried out with thebuilt-in earthing electrodes. Special attention must be given to systems withcathodic protection.By compact mounting:The transmitter must be supplied through ...

Page 6 - AWWA; mating flanges; Torque calculations

6 SITRANS F M MAGFLO      Electromagnetic flowmeter type MAG 5100 W mm inch Nm f/lbs Nm f/lbs Nm f/lbs Nm f/lbs Nm f/lbs 25 1" N/A N/A N/A N/A 10 7 7 5 N/A N/A 40 1½" N/A N/A N/A N/A 16 12 9 7 N/A N/A 50 2" N/A N/A 25 18 N/A N/A 25 18 N/A N/A 65 2½" N/A N/A 25 18 N/A N/A 25 18 N...

Other Siemens Models