Page 2 - For use with Operating System; OPTION CARD; FOR TECHNICAL ASSISTANCE:; IMPORTANT NOTICE; Controlotron is now part of:; Prepared By
Field Manual 1015N-2MFM-1A June 2006 For use with Operating System Software Version 2.00.15 or later 1015N-2M DIAL-UP MODEM OPTION CARD FOR SYSTEM 1010N FLOWMETERS This equipment contains components that aresusceptible to electrostatic discharge (ESD).Please observe ESD control measures duringthe ha...
Page 3 - Manual Changes; and check the Product Manual
Manual Changes NOTE: For the latest updates and revisions to this field manual go to www.controlotron.com/downloads.htm and check the Product Manual listing.
Page 4 - APPENDICES; Page; TABLE OF CONTENTS
1015N-2MFM-1A Table Of Contents 1. Introduction ...................................................................................................... 1 2. 1015N-2M Modem Card Setup ...................................................................... 1 2.1 Option 1 Mounting Kit 1015N-2M-MK1 .........
Page 5 - INSTALLATION INSTRUCTIONS; INTRODUCTION; o r a n y o t h e r
1 1015N-2MFM-1A 1015N-2MFM-1 MODEM CARD INSTALLATION INSTRUCTIONS 1. INTRODUCTION The 1015N-2M Modem Card is one of three option cards used for remote communicationswithin the Controlotron 1010N family of flowmeters. External communication is achievedthrough an on board dial-up miniature modem with ...
Page 6 - TECHNICAL SPECIFICATIONS; volts DC; 010N FLOWMETER SYSTEM REQUIREMENTS; environment or damage to the 1015N-2M Modem Card may result.; Top View
2 1015N-2MFM-1A 3. TECHNICAL SPECIFICATIONS Interface: RS-232 Supply Voltage: 5 volts DC Supply Current: 48 mA Modem Line Speeds: 2400, 1200 and 300 bps Asynchronous DTE Rates: 2400, 1200, 300 bps Modulation: V.22bis, V.22, Bell 212A, Bell 103 Phone Line: Dial Up or 2 Wire Leased Line Extended Hayes...
Page 8 - START VIEW; FINISH VIEW
4 1015N-2MFM-1A CAUTION: Do not connect a serial data cable to J1 on the 1015N-2M Modem Card or damage to the Modem Card and flowmeter may result. 4. Loosen the four captive screws (1) at the corners of the 1010N-2 module (7) and carefully lift out the module disengaging it from the connector on the...
Page 12 - TELEPHONE LINE CONNECTIONS; Connection to the telephone line is made in one of the follows ways:
8 1015N-2MFM-1A 8. Install the 1015N-2M Modem Card (7) on top of the 1010N-8M module (2) carefully engaging connector P1 on the 1015N-2M with its mate P2 on the 1010N-8M module. Secure the1015N-2M by engaging its four captive screws (1) with the four standoffs (4) on the 1010N-8M module. 9. Install ...
Page 13 - SETUP; 015N-2M Reconfiguration Procedure
9 1015N-2MFM-1A 6. COMMUNICATIONS CONFIGURATION The 1015N-2M Modem Card has been pre-configured at the factory to allow for proper interfacewith Controlotron’s System 1010N flowmeters. CAUTION: The 1015N-2M Modem Card will not function properly if the precon- f i g u r e d s e t t i n g s a r e a l ...
Page 14 - Appendix A; APPENDIX A; “AT” COMMAND SET and “S” REGISTERS; The two character sequence AT
A-1 1015N-2MFM-1A Appendix A APPENDIX A “AT” COMMAND SET and “S” REGISTERS The command set for the 1015N-2M modems is fully compatible with the Hayes AT commandset. The modem is controlled and configured by the AT (attention command). Each commandconsists of the following elements (with exception of...
Page 15 - “AT” Commands; Basic AT Commands
A-2 1015N-2MFM-1A Appendix A X0 Report basic call progress result codes, i.e., OK, AI Re-execute command. CONNECT, RING, NO CARRIER (also, for busy, A Go of(-hook and attempt to answer a call. if enabled, and dial tone not detected), B0 Select V.22 connection at 1200 bps. NO ANSWER and ERROR. B1 Sel...
Page 17 - “S” Registers
A-4 1015N-2MFM-1A Appendix A “S” Registers Register Function S0 Rings to auto-answer* S1 Ring counter S2 Escape character* S3 Carriage return character S4 Line feed character S5 Backspace character S6 Maximum time to wait for dial tone* S7 Wait for carrier* S8 Pause time for dial delay modifier* S9 ...
Page 18 - “AT” COMMANDS and “S” REGISTERS
A-5 1015N-2MFM-1A Appendix A “AT” COMMANDS and “S” REGISTERS EXCLUSIVE TO THE PE2400 Dial Modifiers Command Factory Default Parameters/Description ; (semicolon) Return to Idle State. “ ; ” forces the modem to remain in the command state after dialinga number without disconnecting. The semicolon must...
Page 19 - “AT” COMMANDS and ‘S” REGISTERS
A-6 1015N-2MFM-1A Appendix A “AT” COMMANDS and ‘S” REGISTERS EXCLUSIVE TO THE PE2400 Command Factory Default Parameters / Descriptlon %Dn n = 0 DTMF Attenuation. %Dn command sets the DTMF transmit level attenuation. n = 0 0 dB attenuation n =1 2 dB attenuation n = 2 4 dB attenuation n = 3 6 dB atten...
Page 20 - “AT”COMMANDS and “S” REGISTERS
A-7 1015N-2MFM-1A Appendix A “AT”COMMANDS and “S” REGISTERS EXCLUSIVE TO THE PE2400 “S” Registers Notes: *This S-Register is stored in the modem NVRAM upon receipt of the &W command so that the contents are preserved when modem power is removed. Register Range Units Default Description S17 0-250...
Page 21 - APPENDIX B
Appendix B 1015N-2MFM-1A B-1 1015N-2M-MK-7 Assembly, 1015N-2M Module in 1010 Series Flow and Energy Computers 1015N-2M-7 Installation Drawing, Communications Module APPENDIX B ENGINEERING DRAWINGS