Siemens 175V - User Manual

Siemens 175V

Siemens 175V – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 2 – Application; Function diagram
  • Page 3 – IEC
  • Page 4 – haracteristics acc. to; Reset characteristics
  • Page 6 – Function; cos; Settable dropout delay times; Flexible protection functions
  • Page 7 – Motor statistics
  • Page 9 – CB switching cycle diagram; Currents I; EE; Voltages V
  • Page 11 – Communication; System solution/communication
  • Page 14 – Type of network
  • Page 15 – Technical Data page 1; Technical data
  • Page 16 – Technical Data page 2; type tests
  • Page 17 – Technical Data page 3; Unit design
  • Page 18 – Technical Data page 4
  • Page 19 – Technical Data page 5; Voltage protection
  • Page 20 – Technical Data page 6
  • Page 21 – Technical Data page 7
  • Page 22 – Technical Data page 8; for all types of ground faults
  • Page 23 – Technical Data page 9
  • Page 24 – Technical Data page 10; P > limit value of active power
  • Page 25 – Technical Data page 11; Clock
  • Page 26 – Selection and ordering data; Description; SK80 motor protection device; Housing, binary inputs and outputs; Rated auxiliary voltage
  • Page 27 – SK80 motor protection device; No port
  • Page 29 – Sample order; H D; DIGSI 4
  • Page 30 – Connection diagram
  • Page 34 – is connected directly to the shield cap.
  • Page 36 – Dimension drawings in mm / inch
Loading the manual

Function overview

Description

Siemens SIP · 2008

12 Motor Protection / 7SK80

12

12

/9

Protection functions

Time-overcurrent protection
(50, 50N, 51, 51N)

Directional overcurrent protection, ground
(67N)

Sensitive dir./non-dir. ground-fault
detection (50Ns, 67Ns)

Displacement voltage (64)

Inrush restraint

Motor protection
– Undercurrent monitoring (37)
– Starting time supervision (48)
– Restart inhibit (66/86)
– Locked rotor (14)
– Load jam protection (51M)

Overload protection (49)

Temperature monitoring

Under-/overvoltage protection (27/59)

Under-/overfrequency protection (81O/U)

Breaker failure protection (50BF)

Phase unbalance or negative-sequence
protection (46)

Phase-sequence monitoring (47)

Lockout (86)

Control functions/programmable logic

Commands for the ctrl. of CB, disconnect
switches (isolators/isolating switches)

Control through keyboard, binary
inputs, DIGSI 4 or SCADA system

User-defined PLC logic with CFC
(e.g. interl.)

Monitoring functions

Operational measured values V, I, f

Energy metering values W

p

, W

q

Circuit-breaker wear monitoring

Minimum and maximum values

Trip circuit supervision

Fuse failure monitor

8 oscillographic fault records

Motor statistics

Communication interfaces

System/service interface
– IEC 61850
– IEC 60870-5-103
– PROFIBUS-DP
– DNP 3.0
– MODBUS RTU

Ethernet interface for DIGSI 4

USB front interface for DIGSI 4

Hardware

4 current transformers

0/3 voltage transformers

3/7 binary inputs (thresholds
configurable using software)

5/8 binary outputs (2 changeover/
Form C contacts)

0/5 RTD inputs

1 live-status contact

Pluggable current and voltage terminals

SIPROTEC Compact 7SK80
Motor Protection Relay

The SIPROTEC Compact 7SK80 is a multi-
functional motor protection relay. It is de-
signed for asynchronous induction-type
motors of all sizes. The relays have all the
functionality to be applied as a backup relay
to a transformer differential relay.

The 7SK80 features “flexible protection
functions”. 20 additional protection func-
tions can be created by the user. For exam-
ple, a rate of change of frequency function
or a reverse power function can be created.

The relay provides circuit-breaker control,
additional primary switching devices
(grounding switches, transfer switches and
isolating switches) can also be controlled
from the relay. Automation or PLC logic
functionality is also implemented in the
relay. The integrated programmable logic
(CFC) allows the user to add own func-
tions, e.g. for the automation of switch-
gear (including: low voltage starting, auto-
matic restart, interlocking, transfer and
load shedding schemes). The user is also
allowed to generate user-defined messages.

The communication module is independ-
ent from the protection. It can easily be
exchanged or upgraded to future commu-
nication protocols.

Fig. 12/6

SIPROTEC 7SK80
motor protection relay

LS

P

2

874.t

if

Highlights

Removable current and voltage terminals
provide the ideal solution for fast and
secure replacement of relays.

Binary input thresholds and current taps
are software settings. There is thus no need
to ever open the relay to adapt the hardware
configuration to a specific application.

The relay provides 9 programmable func-
tion keys that can be used to replace push-
buttons, select switches and control switches.

The battery for event and fault recording
memory can be exchanged from the front
of the relay.

The relay is available with IEC 61850 for
incredible cost savings in applications (e.g.
transfer schemes with synch-check, bus
interlocking and load shedding schemes).

This compact relay provides protection,
control, metering and PLC logic functional-
ity. Secure and easy to use one page matrix
IO programming is now a standard feature.

The housing creates a sealed dust proof
environment for the relay internal elec-
tronics. Heat build up is dissipated through
the surface area of the steel enclosure. No
dusty or corrosive air can be circulated
over the electronic components. The relay
thus will maintain its tested insulation
characteristic standards per IEC, IEEE,
even if deployed in harsh environment.

Revised Oct. 2008

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Application; Function diagram

Siemens SIP · 2008 12 Motor Protection / 7SK80 12 12 /10 Application Fig. 12/7 Function diagram The SIPROTEC Compact 7SK80 unit is anumerical protection relay that can performcontrol and monitoring functions andtherefore provide the user with a cost-effec-tive platform for asset protection, monitor-...

Page 3 - IEC

Siemens SIP · 2008 12 Motor Protection / 7SK80 12 12 /11 Application ANSI No. IEC Protection functions 50, 50N I>, I>>, I>>>, I E >, I E >>, I E >>> Instantaneous and definite time-overcurrent protection (phase/neutral) 51, 51N I p , I Ep Inverse time-overcurrent ...

Page 4 - haracteristics acc. to; Reset characteristics

Siemens SIP · 2008 12 Motor Protection / 7SK80 12 12 /12 Protection functions Available inverse-time characteristics C haracteristics acc. to ANSI/IEEE IEC 60255-3 Inverse • • Short inverse • Long inverse • • Moderately inverse • Very inverse • • Extremely inverse • • Time-overcurrent protection(ANS...

Other Siemens Models