DU-DR-0016-SC9000 Rev A 6/4/02 GCX Corp. Page 1 of 4

GCX Mounting Assembly Operation/Installation Manual

Dräger Model Cato

®

with Siemens SC9000 Patient Monitor













Patient Monitor – Left Side on Pivot Arm / Power Supply on Right Side

The purpose of these instructions is to:

1. Describe attachment of GCX mounting hardware to the Cato anesthesia machine.

2. Describe attachment of the Siemens monitor to the GCX mounting hardware.

WARNING

: USE OF MOUNTING HARDWARE AND MONITORING COMPONENTS OTHER THAN THOSE

DESCRIBED

IN

THIS

DOCUMENT MAY RESULT IN SERIOUS INJURY DUE TO TIPPING OF THE

ANESTHESIA

MACHINE.

THIS CATO MOUNTING CONFIGURATION REQUIRES THE 40KG COUNTERWEIGHT WITH

EXTENDED

WHEEL

ADAPTER

UPGRADE

SET FROM DRÄGER (PART NUMBER: 86 018 68)

Installer

: When installation is completed, provide these instructions to the end user for future reference.

INSTALLATION

Tools Required: Philips head screw driver, Hex key (incl.).

Mounting the Channel to Cato Edition

Parts Required: 4" Channel, M6 x 16 mm FHMS screws (2).
Brass

Plate

with

inserts

from

Dräger

(M29110)

1. To attach the Channel to the Cato left side accessory track,

locate the brass plate in the accessory track, align the

mounting holes in the Channel with the threaded holes on

the brass plate then run the M5 flat head screws (2) partly

in. (Note: Fixed Stop is at the bottom of the Channel)

2. Set the height of the Channel in the accessory track and

tighten the M6 screws to hold in place.


Prepare M Series Arm

1) Install the Tilt Limiting Stop screw.





M6 x 16 mm (2) FHMS

Accessory Track

Fixed Stop

5/16-18 x ½” SHCS (1)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - the (4) nylon thumb screws on the back of the Mounting Plate.; Install 4” Cato Channel on Right Side; As described on Page 1 of this document.

DU-DR-0016-SC9000 Rev A 6/4/02 GCX Corp. Page 2 of 4 Install M Series Arm 1. The Slide has (2) ¼-20 x ¾” SHSS set screws that, when tightened, secure the Arm at the desired location within the Channel. 2. While supporting the bottom of the Arm with one hand, guide the Slide (at the rear of the arm) ...

Page 3 - Tension Bolt to obtain the desired tension.; Swivel; located under the front end of the Arm.; Cable Management

DU-DR-0016-SC9000 Rev A 6/4/02 GCX Corp. Page 3 of 4 INSTRUCTIONS FOR USE – M Series Pivot Arm Pivot 1. To pivot the Arm (near the wall), simply push on the side of the Arm or mounted device. 2. To adjust the pivot tension at the Slide, use a ½” (or 13mm) socket driver to tighten or loosen the Pivot...

Page 4 - Cleaning; cloth. Dry the arm thoroughly after cleaning.; CAUTION; Siemens Power Supply Holster

DU-DR-0016-SC9000 Rev A 6/4/02 GCX Corp. Page 4 of 4 Cleaning 1. The mounting assembly may be cleaned with most mild, non-abrasive solutions commonly used in the hospital environment (e.g. diluted bleach, ammonia, or alcohol solutions). 2. The surface finish will be permanently damaged by strong che...