Siemens Hicom 300 E CS - User Manual

Siemens Hicom 300 E CS

Siemens Hicom 300 E CS – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
Page: / 34

Table of Contents:

  • Page 2 – N e t wo r k To p o l o g y; C o n f i g u r a t i o n; Use the following steps to configure the Siemens Hicom 300 E CS PBX:
  • Page 3 – S i e m e n s H i c o m 3 3 0 E C S P B X C o n f i g u ra t i o n M e n u s a n d C o m m a n d s; Add the new access code to DPLN.; H500: AMO DPLN STARTED
  • Page 6 – | DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
  • Page 7 – Add the new trunk board using BCSU.; H500: AMO BCSU STARTED
  • Page 8 – Configure Class of Parameter for device handler using COP.; H500: AMO COP STARTED; Add the new trunk group access code using TGACC.; H500: AMO TGACC STARTED
  • Page 9 – DISPLAY; H500: AMO TCSU STARTED
  • Page 11 – C o n f i g u r i n g t h e C i s c o C a l l M a n a g e r
  • Page 13 – R o u t e Pa tt e r n C o n f i g u r a t i o n
  • Page 14 – Te s t R e s u l t s; the ISDN PRI link between a Cisco 2621 and the PBX.
  • Page 15 – link in high impedance mode.; User/Network Settings
  • Page 16 – Table 3; Calls Made
  • Page 17 – Test Setup 2; Setup was as follows:; Table 4; Yes; Table 5
  • Page 18 – A p p e n d i x A; Table 6; Switch and Gateway Settings; isdn protocol—emulate network
  • Page 19 – S i e m e n s H i c o m 3 3 0 E C S S o ft wa re re l e a s e; H500: AMO ANSU STARTED
  • Page 20 – C i s c o 2 6 2 1 R o u te r C o n f i g u ra t i o n
Loading the manual

Cisco Systems, Inc.

All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.

Page 1 of 34

Application Note

Siemens Hicom 300 E CS Rel 6.5 PBX with CallManager using
2621-T1 PRI NI-2 Gateway

This application note illustrates for connectivity of the Siemens Hicom 330 E Rel 3.1

PBX with Cisco CallManager using Cisco 2621-T1 PRI NI1 Gateway.

I n t e g r a t i o n D e s c r i p t i o n

Connectivity is achieved by using the

industry standard PRI NI-2 protocol. The

Siemens Hicom 300 E CS can be configured

as either NETWORK or USER side.

C i s c o Sy s t e m s H a r d wa r e a n d

So ft wa r e R e qu i r e m e n t s

• Hardware (Cisco 2621Gateway):

2MFT T1 Port

• Software: CallManager Release 3.1

P B X H a r d wa r e a n d So ft wa r e

R e qu i r e m e n t s

• Hardware: TMDN or TMDN 64

• Software: Version 6.5

Fe a t u r e s S u p p o r t e d

Key Fe a tu re s S u p p o rte d

Calling/Called Number

Key Fe a tu re s N o t S u p p o rte d

Calling/Called Name

L i m i t a t i o n s

C a l l i n g N a m e a n d N u m b e r fe a tu re

• Calling Name delivery and presentation

features are not supported by the

Siemens Hicom 330 E CS PBX.

• When calling from Cisco 7960 IP phone

to Siemens digital phone, Calling/Called

Number is displayed on both phones

after the call is answered.

• When calling from Siemens digital

phone to Cisco 7960 IP phone, IP phone

displays Connected Number after the

call is answered. Siemens phone

however does NOT get updated when

the call is answered. It displays the

dialed numbers instead. (i.e. Access

Code + extension number). It was

verified using ISDN protocol analyzer

that the CallManager was not sending

"Connected Number” information in

the connect message back to PBX.

• When a call is answered, the display on

the Siemens phone is only active

(Calling Number displayed) for

approximately 4 seconds. Thereafter,

the screen goes blank. This could be

caused by a timer feature that is

expiring for the display.

U s e r / N e t wo rk S e tt i n g s

The Cisco 2621 router with ISDN switch

type setting of primary-ni supports both

protocol sides by using the “isdn

protocol-emulate network/user” command.

When the router is set to emulate Network

side and the Siemens is set to emulate User

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - N e t wo r k To p o l o g y; C o n f i g u r a t i o n; Use the following steps to configure the Siemens Hicom 300 E CS PBX:

Cisco Systems, Inc. All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement. Page 2 of 34 side, the Siemens PBX must send at least 10 digits for the router to properly route the call. Otherwise, the Cisco 2621 router sends back a releas...

Page 3 - S i e m e n s H i c o m 3 3 0 E C S P B X C o n f i g u ra t i o n M e n u s a n d C o m m a n d s; Add the new access code to DPLN.; H500: AMO DPLN STARTED

Cisco Systems, Inc. All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement. Page 3 of 34 S i e m e n s H i c o m 3 3 0 E C S P B X C o n f i g u ra t i o n M e n u s a n d C o m m a n d s Step 1. Add the new access code to DPLN. <di...

Page 6 - | DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |

Cisco Systems, Inc. All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement. Page 6 of 34 | | CALL PROGRESS STATE | DIGIT ANALYSIS| | | | DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE| | |12345 67890 12345 6789012| (SKIP DIGIT...

Other Siemens Models