Sharp AY-XP9FR - Manual

Sharp AY-XP9FR

Sharp AY-XP9FR – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
Page: / 14

Table of Contents:

  • Page 2 – AYXP7FR; Service Manual; SPECIFICATION; MODEL; Electrical data
  • Page 7 – Self-Diagnosis Function and Display Mode; data cannot be called out for display by the LED on the outdoor unit.)
  • Page 8 – times
  • Page 11 – Indoor unit fan
  • Page 12 – Inter-unit wiring error mode
  • Page 13 – NOTE; Heating
  • Page 14 – Cooling
Loading the manual

CHAPTER 1. SPECIFICATION

[1] SPECIFICATION ............................................ 1-1
[2] EXTERNAL

DIMENSION ............................... 1-4

[3] WIRING

DIAGRM .......................................... 1-5

[4] ELECTRICAL

PARTS .................................... 1-6

CHAPTER 2. EXPLAMATION OF CIRCUIT AND OP-
ERATION

[1] BLOCK

DIAGRAMS ....................................... 2-1

[2] MICROCOMPUTER CONTROL SYSTEM

........ 2-3

[3] FUNCTION..................................................... 2-8

CHAPTER 3. FUNCTION AND OPERATION OF PRO-
TECTIVE PROCEDURES

[1]

PROTECTION DEVICE FUNCTIONS AND
OPERATIONS ................................................ 3-1

[2] AIR CONDITIONER OPERATION IN

THERMISTOR ERROR ................................. 3-3

[3] THERMISTOR

TEMPERATURE

CHAR-

ACTERISTICS ............................................... 3-5

[4] HOW TO OPERATE THE OUTDOOR

UNIT INDEPENDENTLY ................................ 3-6

[5] GENERAL

TROUBLESHOOTING

CHART

........ 3-6

[6] MALFUNCTION (PARTS) CHECK METH-

OD ................................................................. 3-8

[7] OUTDOOR UNIT CHECK METHOD ........... 3-10
[8] TROUBLESHOOTING

GUIDE .................... 3-13

CHAPTER 4. REFRIGERATION CYCLE

[1] FLOW

FOW

REFRIGERANT ........................ 4-1

[2] STANDARD

CONDITION .............................. 4-1

[3] TEMPERATURE AT EACH PART AND

PRESSURE IN 3-WAY VALVE ...................... 4-1

[4] PERFORMANCE

CURVES ........................... 4-2

CHAPTER 5. DISASSEMBLING PROCEDURE

[1] DISASSEMBLY OF INDOOR UNIT ............... 5-1
[2] DISASSEMBLY OF OUTDOOR UNIT ........... 5-7

REPLACEMENT PARTS LIST

SERVICE MANUAL

AYXP7FR

S6512AYXP7FR/T

SHARP CORPORATION

CONTENTS

Parts marked with "

" are important for maintaining the safety of the set. Be sure to replace these parts with specified ones for

maintaining the safety and performance of the set.

This document has been published to be used
for after sales service only.
The contents are subject to change without notice.

SPLIT TYPE
ROOM AIR CONDITIONER

OUTDOOR UNIT

AE-X7FR
AE-X9FR
AE-X12FR

MODELS

INDOOR UNIT

AY-XP7FR
AY-XP9FR
AY-XP12FR

In the interests of user-safety (Required by safety regulations in some countries) the set should
be restored to its original condition and only parts identical to those specified should be used.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - AYXP7FR; Service Manual; SPECIFICATION; MODEL; Electrical data

AYXP7FR 1 – 1 AYXP7FR Service Manual CHAPTER 1. SPECIFICATION [1] SPECIFICATION 1. AY-XP7FR – AE-X7FR MODEL INDOOR UNIT OUTDOOR UNIT ITEMS AY-XP7FR AE-X7FR Cooling capacity(Min. > Max.) kW 2.1 (0.9 - 2.5) Heating capacity(Min. > Max.) kW 2.4 (0.9 - 3.4) Moisture removal(at cooling) Liters/h El...

Page 7 - Self-Diagnosis Function and Display Mode; data cannot be called out for display by the LED on the outdoor unit.)

AYXP7FR 3 – 13 [8] TROUBLESHOOTING GUIDE 1. Self-Diagnosis Function and Display Mode To call out the content of the self-diagnosis memory, hold down the emergency operation button for more than 5 seconds when the indoor unit is notoperating. • The number of indications displayed by the LEDs on the o...

Page 8 - times

AYXP7FR 3 – 14 Indoor/outdoor units in complete shutdown 2 times 2 -0 Cycle tempera-ture Compressor high-temperature error (1) Check the outdoor unit air outlet for blockage. (1) Ensure unobstructed air flow from the out-door unit air outlet. (2) Check if the power supply voltage is 90 V or higher a...