Schneider Electric V334 - Manual

Schneider Electric V334

Schneider Electric V334 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

70012-1296-00

ADDENDUM

08/2008

ION, ION Enterprise, MeterM@il,

Modbus, Power Measurement,

PowerLogic,Schneider Electric,

Square D and WebMeter are

either trademarks or registered

trademarks of Schneider Electric

in France, the USA and other

countries. All other trademarks

are property of their respective

owners.
Electrical equipment should be

installed, operated, serviced, and

maintained only by qualified

personnel. No responsibility is

assumed by Schneider Electric for

any consequences arising out of

the use of this material.
© 2008 Schneider Electric.

All rights reserved.
www.global.powerlogic.com

What’s New in v334

Firmware

 

version

 

334

 

(v334)

 

for

 

the

 

ION8800

 

meter

 

offers

 

Modbus

 

Master

 

over

 

TCP/IP.

 

This

 

allows

 

the

 

ION8800

 

to

 

read

 

or

 

record

 

data

 

from

 

Modbus

 

slave

 

devices

 

using

 

up

 

to

 

ten

 

available

 

TCP

 

sockets.

 

The

 

Modbus

 

Master

 

over

 

TCP/IP

 

utilizes

 

one

 

specific,

 

dedicated

 

communications

 

connection

 

that

 

is

 

independent

 

of

 

the

 

existing

 

available

 

maximum

 

4

 

simultaneous

 

Ethernet

 

connections.

N

OTE

To support the new features in v334, download the latest version of ION Setup from
www.global.powerlogic.com.

Modbus

 

Master

 

over

 

TCP/IP

 

must

 

be

 

configured

 

through

 

ION

 

Setup

 

or

 

ION

 

Enterprise

 

software.

 

See

 

the

 

ION8800

 

User

 

Guide

 

for

 

instructions.

As

 

a

 

master,

 

the

 

ION8800

 

can

 

aggregate

 

data

 

from

 

multiple

 

slave

 

devices

 

and

 

then

 

pass

 

it

 

to

 

ION

 

software

 

for

 

analysis.

 

Modbus

 

Master

 

also

 

gives

 

you

 

control

 

of

 

devices

 

on

 

a

 

Modbus

 

network

 

with

 

the

 

meter’s

 

write

 

capability.

There

 

are

 

two

 

communication

 

links

 

to

 

consider

 

when

 

you

 

Modbus

 

Master

 

with

 

the

 

ION8800:

 

the

 

link

 

between

 

the

 

ION

 

software

 

and

 

the

 

ION8800,

 

and

 

the

 

link

 

between

 

the

 

ION8800

 

and

 

the

 

Modbus

 

network.

 

4 simultaneous connections.

Protocols include ION, DNP,

Modbus, etc.

SMTP Server (email)

outgoing only

NEW

TCP/IP Modbus Mastering dedicated

TCP port. Connect with up to 10

Modbus slave IP addresses

Ethernet Connections for the ION8800

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Schneider Electric Models

All Schneider Electric Other