Schneider Electric E4800 - Manual

Schneider Electric E4800

Schneider Electric E4800 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
Page: / 48

Table of Contents:

  • Page 2 – PowerLogic; PLEASE NOTE; DA N G E R
  • Page 3 – UL
  • Page 5 – Table of Contents
  • Page 6 – ii
  • Page 7 – Introduction; INTRODUCTION
  • Page 8 – Table 1: PowerLogic EM4800 series meter specifications; Specification
  • Page 9 – Front Panel Display; — displays 2 rows of 16 characters for each of the meter points; Display button; — cycles through the available information for each of; Left and right arrow buttons; — selects which of the meter points is; Figure 1: PowerLogic EM4880 front panel
  • Page 10 – Figure 2: PowerLogic EM4833 and PowerLogic EM4880 internal view
  • Page 11 – Figure 3: PowerLogic EM4805 internal view
  • Page 12 – Safety Precautions; SAFETY PRECAUTIONS; Carefully observe these safety instructions.; Electrical Standards Compliance; Use the unit only in accordance with the electrical power rating; HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH; NEVER bypass external fusing.
  • Page 13 – Installation; INSTALLATION; Receiving; Pre-Installation Checklist
  • Page 14 – Site Planning; Installation Procedures
  • Page 15 – Mounting the PowerLogic EM4800 meter; Install the conduit for voltage and current connections.
  • Page 16 – Figure 4: 120V Mounting Layout, Dimensions and Clearances
  • Page 18 – Figure 5: Typical three-phase 347V installation; Shorting block detail
  • Page 21 – For a single-phase panel with the 120V variant of the meter:; Connect earth wire to earth post using lug provided
  • Page 26 – Delta service metering; Connect meter neutral terminal to meter terminal B (black wire)
  • Page 27 – Installing the Current Transformers; D A N G E R
  • Page 28 – Figure 13: PowerLogic EM4880 mA current transformer; Connect all CTs to the appropriate circuits; Do not crimp the insulation when making the wire connections.
  • Page 29 – NOTE: The direction of the energy flow is indicated on the CT.; Installing 5A Converters and CTs on the PowerLogic EM4880; It is recommended that 5A converters and shorting devices be
  • Page 30 – Connect the X1 lead of the 5A CT to the shorting device.
  • Page 31 – Figure 14: PowerLogic EM4880 5A CT connection to converter
  • Page 33 – Installing the 5A CTs on the PowerLogic EM4805
  • Page 34 – Repeat steps 5 to 7 for remaining CTs.; Figure 15: Connecting the 5A CT wiring harness
  • Page 35 – Table 3: PowerLogic EM4805 CT color pair identification
  • Page 36 – Connecting the Communications; Ensure that all CT and sense voltage wiring is securely installed.; Manually Testing Communications
  • Page 37 – Pulse Inputs
  • Page 38 – Remote Display
  • Page 40 – Maintenance; MAINTENANCE; Remove the outer cover from the unit.; Figure 17: Replacing the fuse; Fuse holder
  • Page 41 – Regulatory Compliance; REGULATORY COMPLIANCE; Table 4: Regulatory Compliance; Discipline
  • Page 42 – Graphical symbols; Table 5 shows the graphical symbols that appear on the equipment.; Table 5: Graphical symbols that appear on equipment; Symbol
  • Page 43 – English; Index; Numerics
  • Page 44 – ngl
  • Page 45 – user notes; USER NOTES
  • Page 48 – Schneider Electric USA; Installation Guide
Loading the manual

PowerLogic

TM

Series EM4800

Multi-Circuit Meters

Installation Guide

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - PowerLogic; PLEASE NOTE; DA N G E R

PowerLogic TM EM4800 Series 930-110-01-B.00 04/2011 © 201 Schneider Electric All Rights Reserved Hazard Categories and Special Symbols Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service or maintain it. The followi...

Page 3 - UL

930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 © 201 Schneider Electric All Rights Reserved INDUSTRY CANADA CLASS B EMISSION COMPLIANCE STATEMENT This equipment does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the radio interference regulations o...

Page 5 - Table of Contents

930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 Table of Contents © 201 Schneider Electric All Rights Reserved i Table of Contents INTRODUCTION ......................................................................................... 1 System Description ............................................

Other Schneider Electric Models

All Schneider Electric Other