Page 2 - PowerLogic; PLEASE NOTE; DA N G E R
PowerLogic TM EM4800 Series 930-110-01-B.00 04/2011 © 201 Schneider Electric All Rights Reserved Hazard Categories and Special Symbols Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service or maintain it. The followi...
Page 3 - UL
930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 © 201 Schneider Electric All Rights Reserved INDUSTRY CANADA CLASS B EMISSION COMPLIANCE STATEMENT This equipment does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the radio interference regulations o...
Page 5 - Table of Contents
930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 Table of Contents © 201 Schneider Electric All Rights Reserved i Table of Contents INTRODUCTION ......................................................................................... 1 System Description ............................................
Page 6 - ii
PowerLogic TM EM4800 Series 930-110-01-B.00 Table of Contents 04/2011 © 201 Schneider Electric All Rights Reserved ii
Page 7 - Introduction; INTRODUCTION
930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 Introduction © 201 Schneider Electric All Rights Reserved 1 INTRODUCTION This document describes the PowerLogic EM4833, EM4880 and EM4805 meters, including procedures to install and start up the unit, and complete the initial configuration: • “Syst...
Page 8 - Table 1: PowerLogic EM4800 series meter specifications; Specification
PowerLogic TM EM4800 Series 930-110-01-B.00 Introduction 04/2011 © 201 Schneider Electric All Rights Reserved 2 Table 1: PowerLogic EM4800 series meter specifications Specification PowerLogic EM4833 meter PowerLogic EM4880 meter PowerLogic EM4805 meter Dimensions Height: 13.125 in. (33.5 cm)Width: 1...
Page 9 - Front Panel Display; — displays 2 rows of 16 characters for each of the meter points; Display button; — cycles through the available information for each of; Left and right arrow buttons; — selects which of the meter points is; Figure 1: PowerLogic EM4880 front panel
930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 Introduction © 201 Schneider Electric All Rights Reserved 3 Front Panel Display The PowerLogic EM4833, EM4880 and EM4805 meters have the following front panel features (Figure 1 shows the PowerLogic EM4880 front panel): • LCD — displays 2 rows of 1...
Page 10 - Figure 2: PowerLogic EM4833 and PowerLogic EM4880 internal view
PowerLogic TM EM4800 Series 930-110-01-B.00 Introduction 04/2011 © 201 Schneider Electric All Rights Reserved 4 Figure 2 shows the internal view of thePowerLogic EM4833 and PowerLogic EM4880. See Figure 3 for the internal view of the PowerLogic EM4805. Figure 2: PowerLogic EM4833 and PowerLogic EM48...
Page 11 - Figure 3: PowerLogic EM4805 internal view
930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 Introduction © 201 Schneider Electric All Rights Reserved 5 Figure 3: PowerLogic EM4805 internal view 1 2 3 4 12 13 1 5 10 9 1 8 7 6 11 1 15 14 16 17 Legend:1 Cover screw location2 Meter point input (JM8)3 Meter point input (JM1)4 Mounting keyhole5...
Page 12 - Safety Precautions; SAFETY PRECAUTIONS; Carefully observe these safety instructions.; Electrical Standards Compliance; Use the unit only in accordance with the electrical power rating; HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH; NEVER bypass external fusing.
PowerLogic TM EM4800 Series 930-110-01-B.00 Safety Precautions 04/2011 © 201 Schneider Electric All Rights Reserved 6 SAFETY PRECAUTIONS Carefully observe these safety instructions. Electrical Standards Compliance • Use the unit only in accordance with the electrical power rating • The unit is only ...
Page 13 - Installation; INSTALLATION; Receiving; Pre-Installation Checklist
930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 Installation © 201 Schneider Electric All Rights Reserved 7 INSTALLATION This section contains the following installation topics: • “Pre-Installation” on page 7 • “Installation Procedures” on page 8 • “Start-Up Sequence” on page 30 Pre-Installation...
Page 14 - Site Planning; Installation Procedures
PowerLogic TM EM4800 Series 930-110-01-B.00 Installation 04/2011 © 201 Schneider Electric All Rights Reserved 8 If using a modem, these items are also required: • phone or butt set to test the phone line • RJ11 junction box • RJ11 splitter to tap into the existing junction box • RJ11 patch cable • x...
Page 15 - Mounting the PowerLogic EM4800 meter; Install the conduit for voltage and current connections.
930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 Installation © 201 Schneider Electric All Rights Reserved 9 Mounting the PowerLogic EM4800 meter Figure 4 shows the general mounting layout for metering 120V/208V wye services, and Figure 5 shows the general mounting layout for metering 347V/600V w...
Page 16 - Figure 4: 120V Mounting Layout, Dimensions and Clearances
PowerLogic TM EM4800 Series 930-110-01-B.00 Installation 04/2011 © 201 Schneider Electric All Rights Reserved 10 Figure 4: 120V Mounting Layout, Dimensions and Clearances 6.0 in 15.2cm 11.0 in 27.9 cm (6312) 10.67 in 27.1cm 4.0 in 10.2 cm 1 2 2 1 2 2 1 1 3 4 4 6 5 7 8 9 8 Legend:1. Mounting keyhole2...
Page 18 - Figure 5: Typical three-phase 347V installation; Shorting block detail
PowerLogic TM EM4800 Series 930-110-01-B.00 Installation 04/2011 © 201 Schneider Electric All Rights Reserved 12 Figure 5: Typical three-phase 347V installation H1 X1 H2 X2 H1 X1 H2 X2 H1 X1 H2 X2 C B A N C B A N 1 2 3 4 11 Z 5 6 7 8 13 11 12 Shorting block detail 10 9 Legend:1 Shorting block enclos...
Page 21 - For a single-phase panel with the 120V variant of the meter:; Connect earth wire to earth post using lug provided
930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 Installation © 201 Schneider Electric All Rights Reserved 15 For a single-phase panel with the 120V variant of the meter: • Connect meter terminal A to the voltage disconnect phase A (red wire) • Connect meter terminal B to the voltage disconnect p...
Page 26 - Delta service metering; Connect meter neutral terminal to meter terminal B (black wire)
PowerLogic TM EM4800 Series 930-110-01-B.00 Installation 04/2011 © 201 Schneider Electric All Rights Reserved 20 Delta service metering To use the PowerLogic EM4800 meter in a Delta service, the line-to-line voltage from the Delta service must be reduced to 120V line-to-line using appropriate potent...
Page 27 - Installing the Current Transformers; D A N G E R
930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 Installation © 2010 Schneider Electric All Rights Reserved 21 Installing the Current Transformers The three models of PowerLogic EM4800 meter use current transformers (CTs) with different secondary outputs. The PowerLogic EM4833 meter uses split-co...
Page 28 - Figure 13: PowerLogic EM4880 mA current transformer; Connect all CTs to the appropriate circuits; Do not crimp the insulation when making the wire connections.
PowerLogic TM EM4800 Series 930-110-01-B.00 Installation 04/2011 © 201 Schneider Electric All Rights Reserved 22 Figure 13: PowerLogic EM4880 mA current transformer Installing the CTs on the PowerLogic EM4833 and PowerLogic EM4880 Do not apply power until you have made these connections and followed...
Page 29 - NOTE: The direction of the energy flow is indicated on the CT.; Installing 5A Converters and CTs on the PowerLogic EM4880; It is recommended that 5A converters and shorting devices be
930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 Installation © 201 Schneider Electric All Rights Reserved 23 1. Connect the 50-pin connector to the PowerLogic connector located at the bottom side of the unit, and secure it in place with the retaining clips. 2. Feed the free end of the cable thro...
Page 30 - Connect the X1 lead of the 5A CT to the shorting device.
PowerLogic TM EM4800 Series 930-110-01-B.00 Installation 04/2011 © 201 Schneider Electric All Rights Reserved 24 To connect the 5A CT to the converter on the PowerLogic EM4880, follow these steps: 1. Connect the X1 lead of the 5A CT to the shorting device. 2. Connect the X2 lead of the 5A CT to the ...
Page 31 - Figure 14: PowerLogic EM4880 5A CT connection to converter
930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 Installation © 201 Schneider Electric All Rights Reserved 25 Figure 14: PowerLogic EM4880 5A CT connection to converter 7 6 8 11 3 4 1 2 5 10 12 9 Legend:1 Shorting block2 X23 Energy flow4 5A CT5 X1 6 Red (X1)7 5A Converter8 X1 to 25-pair cable9 X2...
Page 33 - Installing the 5A CTs on the PowerLogic EM4805
930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 Installation © 201 Schneider Electric All Rights Reserved 27 Installing the 5A CTs on the PowerLogic EM4805 Use the two 12-pair wiring harnesses provided with the meter to connect the 5A CTs to the PowerLogic EM4805. For wire color coding, see Tabl...
Page 34 - Repeat steps 5 to 7 for remaining CTs.; Figure 15: Connecting the 5A CT wiring harness
PowerLogic TM EM4800 Series 930-110-01-B.00 Installation 04/2011 © 201 Schneider Electric All Rights Reserved 28 8. Repeat steps 5 to 7 for remaining CTs. 9. Remove the shorting block jumper. Figure 15 shows the 5A CT wiring harness connected to the PowerLogic EM4805. Figure 15: Connecting the 5A CT...
Page 35 - Table 3: PowerLogic EM4805 CT color pair identification
930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 Installation © 201 Schneider Electric All Rights Reserved 29 Table 3: PowerLogic EM4805 CT color pair identification 1-phase, 12 or 24 meter points Network- or 1-phase, 12 meter points 3-phase, 8 meter points Meter point ID(meter point #- probe #) ...
Page 36 - Connecting the Communications; Ensure that all CT and sense voltage wiring is securely installed.; Manually Testing Communications
PowerLogic TM EM4800 Series 930-110-01-B.00 Installation 04/2011 © 201 Schneider Electric All Rights Reserved 30 Connecting the Communications Connections for communications using the modem or Ethernet are described in this section. Connecting the Phone Line If the modem reporting option is being us...
Page 37 - Pulse Inputs
930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 Installation © 201 Schneider Electric All Rights Reserved 31 b. If the IP address is not 169.254.0.10, the meter has acquired an IP address from the local network, and will be able to report data and synchronize time. 3. Press the Display button un...
Page 38 - Remote Display
PowerLogic TM EM4800 Series 930-110-01-B.00 Installation 04/2011 © 201 Schneider Electric All Rights Reserved 32 In Diagnostics mode, the right and left arrow buttons scroll the display from meter 1 to 8, 1 to 12, or 1 to 24, depending on your configuration. When the local IP address is shown on the...
Page 40 - Maintenance; MAINTENANCE; Remove the outer cover from the unit.; Figure 17: Replacing the fuse; Fuse holder
PowerLogic TM EM4800 Series 930-110-01-B.00 Maintenance 04/2011 © 201 Schneider Electric All Rights Reserved 34 MAINTENANCE Do not perform any operation or maintenance procedures that are not described in this product documentation. Visually inspect the equipment yearly and ensure it is free of dust...
Page 41 - Regulatory Compliance; REGULATORY COMPLIANCE; Table 4: Regulatory Compliance; Discipline
930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 Regulatory Compliance © 201 Schneider Electric All Rights Reserved 35 REGULATORY COMPLIANCE The PowerLogic EM4800 meter must be installed by a qualified electrician with knowledge of local installation regulations. Initial installation of the unit,...
Page 42 - Graphical symbols; Table 5 shows the graphical symbols that appear on the equipment.; Table 5: Graphical symbols that appear on equipment; Symbol
PowerLogic TM EM4800 Series 930-110-01-B.00 Regulatory Compliance 04/2011 © 201 Schneider Electric All Rights Reserved 36 Graphical symbols Table 5 shows the graphical symbols that appear on the equipment. Table 5: Graphical symbols that appear on equipment Symbol Description Indicates the supply wi...
Page 43 - English; Index; Numerics
930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 Index © 201 Schneider Electric All Rights Reserved 37 English Index Numerics 347V installation typical three-phase configuration 12 5A converters and current transformers install 23 5A current transformers install 27 A audience 1 C compliance elect...
Page 44 - ngl
PowerLogic TM EM4800 Series 930-110-01-B.00 Index 04/2011 © 201 Schneider Electric All Rights Reserved 38 E ngl is h pre-installation 7 pulse inputs 31 pulse inputs 1 and 2 meter 2 S sense voltage meter 2 sense voltage and control voltage cable installation wye and delta service 13 serial port meter...
Page 45 - user notes; USER NOTES
930-110-01-B.00 PowerLogic TM EM4800 Series 04/2011 user notes © 201 Schneider Electric All Rights Reserved 39 USER NOTES
Page 48 - Schneider Electric USA; Installation Guide
Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. 930-110-01-B.00 © 201 Schneider Electric All Rights Reserved 04/2011 Schneider El...