Catalog No.: 3500.24C
Effective: 08-10-11
Replaces: 01-15-08
Job:
Engineer:
Contractor:
Prepared By:
Model:
Indoor Date:
EFFICIENT
82% thermal efficiency – highest of any atmospheric
water heater available today
THERMAL SHOCK PROOF
Twenty-year warranty against thermal shock damage
up to 150°F differential
Maximum outlet temperature: 210°F
LIGHTWEIGHT
A floor load of 70 lbs./sq. ft. or less
HIGH RECOVERY
Cuts fuel costs substantially because the standby
and radiation losses associated with tank-type
water heaters are eliminated
LOW WATER OPERATING TEMPERATURE
Operates with water temperature as low as 105°F
without condensing
Heat Exchanger
ASME Inspected and Stamped
160 PSIG
National Board Approved
Headers
Bronze – Standard
Glass-lined Cast Iron – Option A-2
Fin
Tubing
Copper – Standard
Cupro Nickel – Option A-3
ASME Steel Tube Sheet
Silicone
O-Rings
125 PSIG ASME Pressure Relief Valve
Temperature and Pressure Gauge
Water
Connections
Left Hand – Standard
Right Hand – Option A-6
Two-pass Flow Configuration
Controls
120V, 60Hz, 1 Ph Power Supply
120/24V
Transformer
100% Pilot Shut-off/Lockout
Electronic,
Intermittent Ignition (IID) Pilot
High Limit Control, Manual Reset – 200°F
High Limit Control, Auto Reset – 200°F
Models 3001-4001
On/Off
Switch
Flow
Switch
Economaster II Pump Time Delay
Gas Control Train
Manual Main Gas Shut-off Valve
Main Gas Pressure Regulator
Redundant Safety Shut-off Valve
Control Valve
Firing
Mode
On/Off (WH1)
2-stage Firing (WH3)
Motorized Modulation (WH2)
Fuel
Natural Gas
Propane Gas
Design Certified ANSI Z21.10.3
Construction
Front
Controls
Stainless Steel Burners
Baked Enamel Paint
Built-in Draft Diverter
Draft Inducer – Optional
Motorized Draft Inducer –
Indoor – Option D-2
CSA Certified – AB 1953 & VLA 193
Low Lead Compliant
Water Heater Controller
Required on Model WH2 only
B-40 TempTracker MOD
Modulating
Controller
Mounted
By Others
Temperature Controllers
B-2
Single-Stage Tankstat
(100-180°F), Loose
B-3
2-Stage Tankstat (100-180°F),
Loose
Y-241 Electronic Sequencer,
1-4 Stages
Y-281 Electronic Sequencer,
1-8 Stages
Additional Safety Controls
F-9
Low Water Cut-off Probe
I-3
High Limit Control, Auto Reset,
180°F
S-1
Low Gas Pressure Switch,
Manual
S-2
High Gas Pressure Switch,
Manual
Regulatory Agency Requirements
CSD-1
Safety
Controls
Raytherm
®
- Type WH
Water Heaters
Commercial
Models 2100 - 4001
Proudly Made in the USA