Raypak 2100 - Manual

Raypak 2100

Raypak 2100 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

Catalog No.: 3500.24C

Effective: 08-10-11

Replaces: 01-15-08

Job:

Engineer:

Contractor:

Prepared By:

Model:

Indoor Date:

EFFICIENT

82% thermal efficiency – highest of any atmospheric
water heater available today

THERMAL SHOCK PROOF

Twenty-year warranty against thermal shock damage
up to 150°F differential

Maximum outlet temperature: 210°F

LIGHTWEIGHT

A floor load of 70 lbs./sq. ft. or less

HIGH RECOVERY

Cuts fuel costs substantially because the standby
and radiation losses associated with tank-type
water heaters are eliminated

LOW WATER OPERATING TEMPERATURE

Operates with water temperature as low as 105°F
without condensing

Heat Exchanger

ƒ

ASME Inspected and Stamped
160 PSIG

ƒ

National Board Approved

ƒ

Headers

Bronze – Standard
Glass-lined Cast Iron – Option A-2

ƒ

Fin

Tubing

Copper – Standard
Cupro Nickel – Option A-3

ƒ

ASME Steel Tube Sheet

ƒ

Silicone

O-Rings

ƒ

125 PSIG ASME Pressure Relief Valve

ƒ

Temperature and Pressure Gauge

ƒ

Water

Connections

Left Hand – Standard
Right Hand – Option A-6

ƒ

Two-pass Flow Configuration

Controls

ƒ

120V, 60Hz, 1 Ph Power Supply

ƒ

120/24V

Transformer

ƒ

100% Pilot Shut-off/Lockout

ƒ

Electronic,

Intermittent Ignition (IID) Pilot

ƒ

High Limit Control, Manual Reset – 200°F

ƒ

High Limit Control, Auto Reset – 200°F
Models 3001-4001

ƒ

On/Off

Switch

ƒ

Flow

Switch

ƒ

Economaster II Pump Time Delay

Gas Control Train

ƒ

Manual Main Gas Shut-off Valve

ƒ

Main Gas Pressure Regulator

ƒ

Redundant Safety Shut-off Valve

ƒ

Control Valve

ƒ

Firing

Mode

On/Off (WH1)
2-stage Firing (WH3)
Motorized Modulation (WH2)

ƒ

Fuel

Natural Gas
Propane Gas

ƒ

Design Certified ANSI Z21.10.3

Construction

ƒ

Front

Controls

ƒ

Stainless Steel Burners

ƒ

Baked Enamel Paint

ƒ

Built-in Draft Diverter

ƒ

Draft Inducer – Optional

Motorized Draft Inducer –

Indoor – Option D-2

ƒ

CSA Certified – AB 1953 & VLA 193
Low Lead Compliant



Water Heater Controller

Required on Model WH2 only

B-40 TempTracker MOD

Modulating

Controller

Mounted

By Others

Temperature Controllers

B-2

Single-Stage Tankstat
(100-180°F), Loose

B-3

2-Stage Tankstat (100-180°F),
Loose

Y-241 Electronic Sequencer,

1-4 Stages

Y-281 Electronic Sequencer,

1-8 Stages

Additional Safety Controls

F-9

Low Water Cut-off Probe

I-3

High Limit Control, Auto Reset,
180°F

S-1

Low Gas Pressure Switch,
Manual

S-2

High Gas Pressure Switch,
Manual

Regulatory Agency Requirements

CSD-1

Safety

Controls

Raytherm

®

- Type WH

Water Heaters

Commercial

Models 2100 - 4001

Proudly Made in the USA

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Raypak Models

All Raypak Other