Page 3 - Contents
C311M-N (6/06) 3 Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Regulatory Notices . . . . . . . . . . . . . . . . . . . ....
Page 4 - List of Tables
4 C311M-N (6/06) Turning Limit Stops On Or Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Programming Limit Stops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 5 - Important Safety Instructions; RISK OF ELECTRIC SHOCK.
C311M-N (6/06) 5 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 6. Do not install near any heat sources such ...
Page 6 - Regulatory Notices; RADIO AND TELEVISION INTERFERENCE
6 C311M-N (6/06) Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired...
Page 7 - Description; MODELS; Model Numbers; Model
C311M-N (6/06) 7 Description The ES30PC/ES31PC Esprit Series is designed to protect camera optics and electronics from moisture and airborne contaminants. The system features a receiver, pan and tilt, enclosure, and a pressurized integrated optics cartridge (IOC). The integrated optics cartridge pac...
Page 8 - Installation; MODEL
8 C311M-N (6/06) Installation 1. When installing the ES30PC/ES31PC Esprit ® system, allow for sufficient clearance between the top of the unit and overhead obstructions. This will prevent interference when the enclosure is driven to its maximum elevation of 33 degrees. 2. Remove the transformer modu...
Page 12 - TXB Series Translator Board Installation (Optional); HOW TO REMOVE THE PAN AND TILT COVER
12 C311M-N (6/06) TXB Series Translator Board Installation (Optional) Pelco’s TXB Series allows controllers from other companies to communicate with the Esprit system. To install a TXB Series board, remove the left cover of the pan and tilt. Once the cover is removed, refer to the manual supplied wi...
Page 14 - Operation; HOW TO OPERATE YOUR SYSTEM; ENVIRONMENTAL RANGE
14 C311M-N (6/06) Operation POWER-UP DISPLAY When the system is powered up, the selected protocol, revision number, and other information is displayed on the monitor. For example, the screen might show the following information: HOW TO OPERATE YOUR SYSTEM OPERATING NOTES ENVIRONMENTAL RANGE The oper...
Page 15 - CONDITION
C311M-N (6/06) 15 PRESSURIZED INTEGRATED OPTICS CARTRIDGE The pressurized IOC houses an auto focus camera, lens, heater, and sensors in a self-contained, sealed unit. Dry nitrogen pressurized to 10 psig controls the environment inside the cartridge, eliminating internal condensation and corrosion. S...
Page 16 - Controller
16 C311M-N (6/06) CURRENT READING MENU The Current Reading menu displays the existing status of temperature, pressure, and dewpoint inside the integrated optics cartridge. An asterisk displayed to the left of a menu item denotes that an alert condition exists. Due to the heat emitted from the electr...
Page 22 - Standard Coaxitron Mode; Extended Coaxitron or RS-485 Mode; Endura Systems
22 C311M-N (6/06) KBD4000/KBD4002/KBD4000V 1. Press the SPOT MONITOR key. 2. Enter 95, and then hold the PRESET key (approximately five seconds) until the main menu appears on the screen. MPT9500 Standard Coaxitron Mode 1. Enter 95 and press the PRESET SET key. 2. Position the asterisk in the YES ro...
Page 24 - ALERT DISPLAY POSITION
24 C311M-N (6/06) ALERT DISPLAY POSITION Screen positioning of the alert label is user-defined. Positioning options include the following: To set the alert label position: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Alert. 3. Press the Iris Open button to e...
Page 25 - ALERT REPEAT
C311M-N (6/06) 25 ALERT REPEAT You can program how often an ALERT label is repeatedly displayed until it is acknowledged by the system controller. The following settings are available: • Constant: The ALERT label is continually displayed on the monitor until acknowledged. • 15 min off: The ALERT lab...
Page 26 - AUTO FOCUS MODE
26 C311M-N (6/06) AUTO FOCUS MODE There are two auto focus modes: • Auto: If auto focus is in the auto mode, pressing the Focus Far or Focus Near button will place the focus in the manual mode. The system will return to auto focus if you pan or tilt the unit or do a zoom function. • Off: If the mode...
Page 27 - AUTO IRIS
C311M-N (6/06) 27 AUTO IRIS The following are the settings for auto iris: Mode, Level, and Peak. To change the settings for auto iris: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Camera. 3. Press the Iris Open button to enter the Camera menu. 4. Position th...
Page 29 - AUTO SHARPNESS
C311M-N (6/06) 29 AUTO SHARPNESS The following settings are available for auto sharpness: • On: Automatically sets the sharpness of the camera. • Off: The sharpness of the camera needs to be manually set (refer to Sharpness). To change the mode: 1. Program preset 95 (28). The main menu appears. 2. P...
Page 32 - AZIMUTH ZERO
32 C311M-N (6/06) AZIMUTH ZERO Azimuth is the pan angle from 0 to 359 degrees. Azimuth zero is the programmed zero-degree point that is normally set to magnetic north. Once programmed, on-screen pan position (azimuth) and compass readings are based on the set azimuth zero point. To set azimuth zero:...
Page 33 - BACKLIGHT COMPENSATION
C311M-N (6/06) 33 BACKLIGHT COMPENSATION There are two backlight compensation modes: • On: The system uses the center 10 percent of the picture to adjust the iris. If there is a bright light source outside of this area, it will wash out to white. The camera will adjust the iris so that the object in...
Page 34 - DIRECTION
34 C311M-N (6/06) DIRECTION Direction programs the horizontal display position of the Direction label (N, NW, NE, …). NOTES: • For direction to be accurate, azimuth zero must be set to magnetic north. • Direction display is not available while you are programming or running a pattern. The following ...
Page 35 - DIRECTION LINE
C311M-N (6/06) 35 DIRECTION LINE Direction Line controls the vertical display position of the Direction label. The label may be displayed on lines 3 through 10. Line 3 is the third line from the top of the screen and line 10 is located at the bottom of the screen. Line 10 is the default setting. NOT...
Page 36 - DISPLAY DURATION
36 C311M-N (6/06) DISPLAY DURATION Display Duration programs the duration the Az/El, Direction, and Zoom labels are displayed on the monitor. The available settings for display duration include the following: • Constant: The label is displayed continuously. • 2 Seconds (default): The label is displa...
Page 37 - GAIN LIMIT
C311M-N (6/06) 37 GAIN/AGC GAIN LIMIT The gain limit sets the maximum level for the automatic gain control. Increasing the level will increase the signal level and increase the noise level of the picture. To change the gain: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (&...
Page 39 - LIMIT STOPS; TURNING LIMIT STOPS ON OR OFF; Manual Limit Stops; Presets
C311M-N (6/06) 39 LIMIT STOPS NOTE: Limit stops are inactive while setting items in the program menu (e.g. azimuth zero, scan limits, manual pan limits). TURNING LIMIT STOPS ON OR OFF To change the limit stop mode: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) besid...
Page 40 - Limit Stops Menu; Clear Manual Stops; Scan Limit Stops
40 C311M-N (6/06) Limit Stops Menu The manual pan limit stops can be set at the controller using the Limit Stops menu: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Limit Stop. 3. Press the Iris Open button to enter the Limit Stop menu. 4. Move the cursor to ...
Page 41 - Clear Scan Limit Stops
C311M-N (6/06) 41 Limit Stops Menu The manual pan limit stops can be set at the controller using the Limit Stops menu: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Limit Stop. 3. Press the Iris Open button to enter the Limit Stop menu. 4. Move the cursor to ...
Page 42 - LINE SYNCHRONIZATION
42 C311M-N (6/06) LINE SYNCHRONIZATION If cameras are out of phase with each other, they may produce what appears to be vertical roll when switching between cameras. There are two settings for line synchronization: • On: Adjust the synchronization of the power line voltage so that it is in phase wit...
Page 44 - PARK TIME MINUTES
44 C311M-N (6/06) PARK TIME MINUTES This feature causes the system to park at preset 1 after a programmed number of minutes of control inactivity. The time can be set from 1 minute to 720 minutes (12 hours), or it can be set to zero, which disables this feature. NOTE: Preset 1 must be programmed for...
Page 45 - PATTERN LENGTH
C311M-N (6/06) 45 PATTERN LENGTH The Esprit can do the following: • One full pattern that is 1.5, 3, or 6 minutes long. • Two half patterns that is .75, 1.5, or 3 minutes long. This pattern can consist of any standard pan and tilt or lens command. Presets, flip, and turbo are not allowed in a patter...
Page 47 - PROPORTIONAL PAN
C311M-N (6/06) 47 PROPORTIONAL PAN There are two proportional pan modes: • On: Enables the proportional pan mode. The amount of zoom controls the pan and tilt. At telephoto zoom settings, the pan and tilt speeds will be slower for a given amount of joystick deflection than at wide zoom settings. Thi...
Page 48 - RESET CAMERA; Default Setting
48 C311M-N (6/06) RESET CAMERA Resetting the camera returns the settings to their defaults. Turning off power does not reset the camera. Camera settings are retained in memory. When the power is turned back on, the settings will be the same as they were when the power was turned off. To reset the ca...
Page 49 - SCAN SPEED
C311M-N (6/06) 49 SCAN SPEED The scan speed is adjustable from 1-40 degrees per second. This occurs in three scan modes: auto, random, and frame scan. To change the scan speed: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Other. 3. Press the Iris Open button...
Page 50 - SHARPNESS
50 C311M-N (6/06) SHARPNESS Use the Sharpness setting to manually set the sharpness of the camera. To manually set the sharpness of the camera: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Camera. 3. Press the Iris Open button to enter the Camera menu. 4. Po...
Page 51 - SHUTTER SPEED
C311M-N (6/06) 51 SHUTTER SPEED There are several electronic shutter speed settings: In the Auto setting the camera controls the shutter speed automatically. Increasing the shutter speed lowers the light sensitivity, but rapidly moving objects will be less blurred. NOTE: (ES30PCBW24/ES31PCBW24) If t...
Page 52 - SPEED PROFILE
52 C311M-N (6/06) SPEED PROFILE This feature allows the operator to set the wind speed conditions for the location of the Esprit system. You can set two wind speed profiles of 50 mph or 90 mph in which the system will remain operational. In both settings, the pan speed will be a maximum of 40 degree...
Page 53 - WHITE BALANCE
C311M-N (6/06) 53 WHITE BALANCE The settings for white balance are as follows: • Auto white bal • R Gain • B Gain To change the white balance settings: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Camera. 3. Press the Iris Open button to enter the Camera men...
Page 54 - WIPER MODE
54 C311M-N (6/06) WIPER MODE There are three wiper settings: • Wiper Mode (Momentary or Continuous) • Wiper Dwell • Wiper Time To change the wiper settings: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Wiper. 3. Press the Iris Open button to enter the Wiper ...
Page 56 - ZOOM
56 C311M-N (6/06) ZOOM Zoom programs the horizontal display position of the Zoom label. The following settings are available for the Zoom label: • Off: Label is not displayed. • Left: Label is displayed on the left-hand side of the screen. • Center (default): Label is displayed in the center of the ...
Page 57 - ZOOM LIMIT
C311M-N (6/06) 57 ZOOM LIMIT ES30PC16/ES31PC16: 16X optical zoom and 10X electronic zoom, can be set for 16X, 32X, 64X, 128X, or 160X. ES30PC22/ES31PC22: 22X optical zoom and 10X electronic zoom, can be set for 22X, 32X, 88X, 176X, or 220X. ES30PCBW24/ES31PCBW24: 24X optical zoom and 10X electronic ...
Page 58 - ZOOM LINE
58 C311M-N (6/06) ZOOM LINE Zoom Line controls the vertical display position of the Zoom label. The label may be displayed on lines 3 through 10. Line 3 is the third line from the top of the screen and line 10 is located at the bottom of the screen. Line 10 is the default setting. NOTE: Zoom display...
Page 59 - Troubleshooting; Symptom; Symptom: Ground loops
C311M-N (6/06) 59 Troubleshooting NOTE: The system contains no user-serviceable parts. If there is a problem with your system, it must be returned to Pelco for servicing. Symptom: System does not operate. 1. Check system input voltage. 2. The Esprit system is protected by a resettable overcurrent pr...
Page 61 - Maintenance; WIPER
C311M-N (6/06) 61 Maintenance Clean the enclosure window periodically with a mild non-abrasive detergent in water and a soft cloth to help maintain picture clarity. If operating problems are experienced with the system, refer to the Troubleshooting section. WIPER If the window wiper assembly is inst...
Page 62 - PRESSURIZED IOC; Removing the IOC
62 C311M-N (6/06) PRESSURIZED IOC IMPORTANT: Disconnect power to the Esprit system before removing or installing the pressurized cartridge. Software conflicts can occur if the Esprit is not powered-down before removing/installing the IOC. There are no user-serviceable parts internal to the pressuriz...
Page 63 - Appendix; Switch Setting
C311M-N (6/06) 63 Appendix NOTE: Esprit will sense and automatically select input from Coaxitron control signals in either the standard or extended mode. Therefore, the DIP switch settings have no effect on Coaxitron control signals. *SW1-3 is not used; set it in the OFF position. *SW1-4 is not used...
Page 67 - Specifications; ELECTRICAL
C311M-N (6/06) 67 Specifications ELECTRICAL Input Voltage 24, 120, or 230 VAC, 50/60 Hz; switch selectable for 120/230 VAC inputs. Reset feature enabled when power becomes unstable or interrupted. Power Requirements Maximum power consumption is 70 VA per system Heater and Defroster Thermostatically ...
Page 69 - PRODUCT WARRANTY AND RETURN INFORMATION
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material orworkmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FR/FT/FS Series fiber optic p...