Napoleon GS 28-P - Manual

Napoleon GS 28-P

Napoleon GS 28-P – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 2 – M O D E L G D S 2 8; TABLE OF CONTENTS; be done by a licensed or qualified service person.
  • Page 4 – Do not substitute materials.; GENERAL INSTRUCTIONS
  • Page 5 – MAINTAIN THESE MINIMUM CLEARANCES TO; LOCATION AND CLEARANCES; FIGURE 2; VENTING LENGTHS AND AIR TERMI-; WALL TERMINAL KIT GD175; STOVE PERISCOPE; DIRECT VENT SPECIFICS - GDS28; FIGURE 1
  • Page 6 – SPECIAL INSTALLATION EXAMPLE; OFFSET INSTALLATION EXAMPLE; FIGURE 4; first run of 72 inches; FIGURE 6; Do not include the first elbow directly off the unit.
  • Page 7 – non; CANADIAN; INSTALLATIONS
  • Page 8 – VERTICAL INSTALLATION:; VENT; F I G U R E S; OR; WALL AND CEILING PROTECTION
  • Page 9 – VERTICAL VENTING INSTALLATION; HORIZONTAL VENTING INSTALLATION
  • Page 10 – SPEED SWITCH
  • Page 11 – ADAPTER INSTALLATION; To pass the wires through
  • Page 12 – COMBUSTION AIR; INSTALLING FLASHING AND STORM
  • Page 13 – Mark the appropriate boxes; DO NOT KINK FLEXIBLE CONNECTOR.; GA S INSTALL ATION; DO NOT USE OPEN FLAME.
  • Page 14 – DOOR CLOSING AND OPENING; F I N I S H I N G; LOG PLACEMENT INSTRUCTIONS; Positioning the logs improperly will cause flame; Fine dust found in the bottom of the bag should not
  • Page 15 – VENTING ACTION; OPERATION / MAINTENANCE; OPERATING INSTRUCTIONS; WHAT TO DO IF YOU SMELL GAS:
  • Page 16 – LIGHTING INSTRUCTIONS; MAINTENANCE INSTRUCTIONS; Turn off the gas and unplug electrical; TO TURN OFF GAS
  • Page 17 – REPLACEMENT BLOWER; INSTALLATION THROUGH THE REAR; FOR MODEL GDS28; INSTALLATION THROUGH THE FIRE-; FIGURE 35 - INSTALLATION FROM THE FRONT
  • Page 18 – PILOT BURNER ADJUSTMENT; FLAME MUST ENVELOP; A D J U S T M E N T S; VENTURI ADJUSTMENT
  • Page 19 – R E P L A C E M E N T S; ORDERING REPLACEMENT PARTS; DESCRIPTION
  • Page 21 – PROBLEM; TROUBLE SHOOTING GUIDE
  • Page 23 – Wolf Steel Fireplace Service History; This fireplace must be serviced annually depending on usage.
Loading the manual

1

W415-0153 / A / 10.29.01

I N S TA L L AT I O N A N D O P E R AT I O N I N S T R U C T I O N S F O R :

V E N T E D G A S F I R E P L A C E H E AT E R

NATURAL GAS MODELS

GDS 28-N

and

GS 28-N

PROPANE GAS MODELS

GDS 28-P and

GS 28-P

Model GS28 is made up of Model GDS28 and B-Vent Adapter Kit GS-150KT

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88

Fax:

(705)722-6031

Email:

[email protected]

Web:

www.napoleonfireplaces.com

Wolf Steel Ltd., 24 Napoleon Rd.,

Barrie, ON., Canada L4M 4Y8 (705)721-1212

R-2000

Installation and service must be performed by a qualified installer, service

agency or the gas supplier.

WARNING: If the information in these instructions is not followed exactly, a fire or

explosion may result causing property damage, personal injury or death.

F O R Y O U R S A F E T Y

Do not store or use gasoline or other flammable vapours and liquids in the vicinity of

this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.

• Immediately call your gas supplier from
a neighbour's phone. Follow the gas sup-
plier's instructions.
• If you cannot reach your gas supplier,
call the fire department.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - M O D E L G D S 2 8; TABLE OF CONTENTS; be done by a licensed or qualified service person.

2 W415-0153 / A / 10.29.01 PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE Pg 13 GAS INSTALLATION Remote Wall Switch / Thermostat 14 FINISHING Door Closing & OpeningLog Placement 15-16 OPERATION / MAINTENANCE Spill SwitchVenting Action CheckOperating InstructionsMaintenance 17 REPLACEMENT BLOWER ...

Page 4 - Do not substitute materials.; GENERAL INSTRUCTIONS

4 W415-0153 / A / 10.29.01 GENERAL INFORMATION For your satisfaction, this stove has been test-firedto assure its operation and quality! Minimum inlet gas supply pressure is 4.5 inches watercolumn for natural gas and 11 inches water column forpropane. Maximum inlet gas pressure is 7 inches watercolu...

Page 5 - MAINTAIN THESE MINIMUM CLEARANCES TO; LOCATION AND CLEARANCES; FIGURE 2; VENTING LENGTHS AND AIR TERMI-; WALL TERMINAL KIT GD175; STOVE PERISCOPE; DIRECT VENT SPECIFICS - GDS28; FIGURE 1

5 W415-0153 / A / 10.29.01 MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES: A. 7" D. 14 3 / 4 " B. 2" E. 4" C. 1" * F. 9½" N O ADDITIONAL FLOOR PROTECTION IS REQUIRED MINIMUM 20" FROM STOVE TOP TO CEILING * AT A DISTANCE OF 1" FROM THE WALL , ACCESS TO THE BLOWER SW...

Other Napoleon Models

All Napoleon Other